HVAC Rated

5-ton packaged heat pump · ENLIGHT

Lennox LDT060H4E*1P

Below average cooling and heating efficiency for a 5-ton packaged heat pump, but not rated for cold climates.

Ranks #22 of 29 5 ton packaged heat pumps for cooling efficiency, and costs about $1,975 a year to run in a mixed climate like Atlanta.

SEER2
15.2 Cooling efficiency over a season
Below average · beats 24%
HSPF2
7.2 Heating efficiency over a season
Below average · beats 25%
EER2
11.4 Cooling efficiency on a 95°F day
Below average · beats 38%
Heat at 5°F
42,000 BTU/h76% of its 47°F output
Excellent · beats 96%

A good fit if…

  • You want a certified 5-ton packaged heat pump at a typical efficiency level.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for packaged heat pumps.
  • You mainly need heat - its HSPF2 is below average for packaged heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications5 ton, R-410A
General
BrandLennox
Also sold asALLIED COMMERCIAL
Outdoor unit modelLDT060H4E*1P
SeriesENLIGHT
TypePackaged heat pump
Nominal size5 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceFebruary 2, 2023
Last certifiedMay 1, 2026
Cooling
SEER2Seasonal efficiency, higher is better15.2 (range 15.2)
EER2Efficiency at 95°F outdoors11.4
Cooling capacity55,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.2
Capacity at 47°F55,000 BTU/h
Capacity at 17°F30,000 BTU/h
Capacity at 5°F42,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.22
ENERGY STAR cold climateNo
Heating output as it gets colder76% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:

Certified matchups2 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
-15.211.47.242,000211198007
-15.211.47.242,000211239263
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Lennox LDT060H4E*1P: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,704-$4,772

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Lennox LDT060H4E*1P?
The Lennox LDT060H4E*1P is rated at up to 15.2 SEER2 and 11.4 EER2 for cooling and up to 7.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Lennox LDT060H4E*1P good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 5-ton model.
How much does the Lennox LDT060H4E*1P cost to run per year?
At its rated efficiency it costs about $1,704-$4,772 a year in electricity in large U.S. cities, depending on climate and local rates - for example $2,130 in Phoenix and $4,010 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Lennox LDT060H4E*1P the same as the Lennox LHT060H4E*1P?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
What refrigerant does the Lennox LDT060H4E*1P use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $2,129/yrYou save $707/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Lennox LDT060H4E*1P
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$2,129
Current system, per year
$2,836
You save per year
$707
Payback
29.0 years
Net after 10 years
-$13,433

Cooling $1,274Heating $856Electricity used: 13,308 kWhSaved vs. a minimum-efficiency heat pump: $46

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 5 ton models

See all 29 5 ton packaged heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 1, 2026. How we use the data.