5-ton packaged heat pump · ENLIGHT
Lennox LDT060H4E*1P
Below average cooling and heating efficiency for a 5-ton packaged heat pump, but not rated for cold climates.
Ranks #22 of 29 5 ton packaged heat pumps for cooling efficiency, and costs about $1,975 a year to run in a mixed climate like Atlanta.
- SEER2
- 15.2 Cooling efficiency over a seasonBelow average · beats 24%
- HSPF2
- 7.2 Heating efficiency over a seasonBelow average · beats 25%
- EER2
- 11.4 Cooling efficiency on a 95°F dayBelow average · beats 38%
- Heat at 5°F
- 42,000 BTU/h76% of its 47°F outputExcellent · beats 96%
A good fit if…
- You want a certified 5-ton packaged heat pump at a typical efficiency level.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for packaged heat pumps.
- You mainly need heat - its HSPF2 is below average for packaged heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Lennox |
| Also sold as | ALLIED COMMERCIAL |
| Outdoor unit model | LDT060H4E*1P |
| Series | ENLIGHT |
| Type | Packaged heat pump |
| Nominal size | 5 ton |
| CompressorVariable-speed units run longer at low power | Two-stage |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | February 2, 2023 |
| Last certified | May 1, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 15.2 (range 15.2) |
| EER2Efficiency at 95°F outdoors | 11.4 |
| Cooling capacity | 55,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.2 |
| Capacity at 47°F | 55,000 BTU/h |
| Capacity at 17°F | 30,000 BTU/h |
| Capacity at 5°F | 42,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.22 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - | 15.2 | 11.4 | 7.2 | 42,000 | 211198007 |
| - | 15.2 | 11.4 | 7.2 | 42,000 | 211239263 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the Lennox LDT060H4E*1P: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- Lennox LHT060H4E*1P
Yearly running cost in 10 large cities
- Phoenix, AZ$2,130/yr
- Miami, FL$1,704/yr
- Houston, TX$1,911/yr
- Atlanta, GA$1,975/yr
- Los Angeles, CA$1,931/yr
- New York, NY$4,772/yr
- Chicago, IL$3,884/yr
- Denver, CO$3,237/yr
- Seattle, WA$1,995/yr
- Minneapolis, MN$4,010/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Lennox LDT060H4E*1P?
- The Lennox LDT060H4E*1P is rated at up to 15.2 SEER2 and 11.4 EER2 for cooling and up to 7.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Lennox LDT060H4E*1P good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 5-ton model.
- How much does the Lennox LDT060H4E*1P cost to run per year?
- At its rated efficiency it costs about $1,704-$4,772 a year in electricity in large U.S. cities, depending on climate and local rates - for example $2,130 in Phoenix and $4,010 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Lennox LDT060H4E*1P the same as the Lennox LHT060H4E*1P?
- Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- What refrigerant does the Lennox LDT060H4E*1P use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 5 ton models
- Fujitsu RDFXYC060AJV15.2 SEER2 · 7.2 HSPF2
- ALLIED COMMERCIAL LDT060H5E*1P15.2 SEER2 · 7.2 HSPF2
- Rheem RHPBYC060AJT15.2 SEER2 · 7.2 HSPF2
- AIREASE RPHPV-71560P-15.2 SEER2 · 7.2 HSPF2
- Rheem RHPXYC060AJT15.2 SEER2 · 7.2 HSPF2
- Heil PHR560000K***K115.2 SEER2 · 7.5 HSPF2
- Rheem RHPXZS060AJT15.2 SEER2 · 7.2 HSPF2
- Carrier 50VR-K60---3015.2 SEER2 · 7.5 HSPF2
See all 29 5 ton packaged heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 1, 2026. How we use the data.