HVAC Rated

24,000 BTU mini-split heat pump · KUSAE241A

LG KUSAE241A

Below average cooling and heating efficiency for a 24,000 BTU mini-split heat pump, but not rated for cold climates.

Ranks #415 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $670 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Below average · beats 4%
HSPF2
8.3 Heating efficiency over a season
Below average · beats 1%
EER2
12.0 Cooling efficiency on a 95°F day
Below average · beats 25%
Heat at 5°F
13,800 BTU/h63% of its 47°F output
Below average · beats 0%

A good fit if…

  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You mainly need heat - its HSPF2 is below average for mini-splits.

Calculate my running cost

Details

Specifications24,000 BTU, R-32
General
BrandLG
Outdoor unit modelKUSAE241A
SeriesKUSAE241A
TypeMini-split heat pump
Nominal size24,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceDecember 23, 2024
Last certifiedDecember 2, 2025
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 18.0)
EER2Efficiency at 95°F outdoors12.0
Cooling capacity21,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.3
Capacity at 47°F22,000 BTU/h
Capacity at 17°F13,500 BTU/h
Capacity at 5°F13,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.70
ENERGY STAR cold climateNo
Heating output as it gets colder63% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with KNSAE241A at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
KNSAE241A18.012.08.313,800214931169
Yearly running cost in 10 large cities$556-$1,637

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the LG KUSAE241A?
The LG KUSAE241A is rated at up to 18.0 SEER2 and 12.0 EER2 for cooling and up to 8.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the LG KUSAE241A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 24,000 BTU model.
How much does the LG KUSAE241A cost to run per year?
At its rated efficiency it costs about $556-$1,637 a year in electricity in large U.S. cities, depending on climate and local rates - for example $706 in Phoenix and $1,384 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the LG KUSAE241A?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses KNSAE241A.
What refrigerant does the LG KUSAE241A use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $711/yrYou save $395/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump LG KUSAE241A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$711
Current system, per year
$1,106
You save per year
$395
Payback
20.3 years
Net after 10 years
-$4,052

Cooling $415Heating $297Electricity used: 4,447 kWhSaved vs. a minimum-efficiency heat pump: $139

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 24,000 BTU models

See all 430 24,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of December 2, 2025. How we use the data.