48,000 BTU mini-split heat pump · ML Series
Mainline ML48HP230LCMH-O
Below average cooling efficiency and very good heating efficiency for a 48,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #114 of 146 48,000 BTU mini-splits for cooling efficiency, and costs about $1,292 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.5 Cooling efficiency over a seasonBelow average · beats 6%
- HSPF2
- 11.0 Heating efficiency over a seasonVery good · beats 75%
- EER2
- 9.4 Cooling efficiency on a 95°F dayBelow average · beats 2%
- Heat at 5°F
- 47,500 BTU/h90% of its 47°F outputAverage · beats 48%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 47,500 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 75% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for mini-splits.
Details
Specifications
| General | |
|---|---|
| Brand | Mainline |
| Outdoor unit model | ML48HP230LCMH-O |
| Series | ML Series |
| Type | Mini-split heat pump |
| Nominal size | 48,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | May 20, 2024 |
| Last certified | August 19, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.5 (range 16.7-18.5) |
| EER2Efficiency at 95°F outdoors | 9.4-10.4 |
| Cooling capacity | 48,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.1-11.0 |
| Capacity at 47°F | 50,000-53,000 BTU/h |
| Capacity at 17°F | 38,500-45,000 BTU/h |
| Capacity at 5°F | 46,000-47,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.83-2.00 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with ML48HP230FLO-I at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| ML48HP230FLO-I MAINLINE · cold climate | 18.5 | 9.4 | 10.1 | 47,000 | 217607313 |
| ML48HP230FLO-I MAINLINE · cold climate | 18.5 | 9.4 | 10.1 | 47,000 | 215864404 |
| ML48HP230STDCAS-I MAINLINE · cold climate | 18.0 | 10.0 | 11.0 | 47,500 | 217607308 |
| ML48HP230STDCAS-I MAINLINE · cold climate | 18.0 | 10.0 | 11.0 | 47,500 | 215864399 |
| ML48HP230RS485AHU-I · cold climate | 17.0 | 10.0 | 10.2 | 46,000 | 217607166 |
| ML48HP230RS485AHU-I · cold climate | 17.0 | 10.0 | 10.2 | 46,000 | 215864302 |
| ML48HP230HSDUC-I MAINLINE · cold climate | 16.7 | 10.4 | 10.8 | 47,500 | 217607310 |
| ML48HP230HSDUC-I MAINLINE · cold climate | 16.7 | 10.4 | 10.8 | 47,500 | 215864401 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,469/yr
- Miami, FL$1,216/yr
- Houston, TX$1,316/yr
- Atlanta, GA$1,292/yr
- Los Angeles, CA$1,248/yr
- New York, NY$3,039/yr
- Chicago, IL$2,458/yr
- Denver, CO$2,036/yr
- Seattle, WA$1,245/yr
- Minneapolis, MN$2,516/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Mainline ML48HP230LCMH-O?
- The Mainline ML48HP230LCMH-O is rated at up to 18.5 SEER2 and 9.4 EER2 for cooling and up to 11.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 8 certified matchups SEER2 ranges from 16.7-18.5.
- Is the Mainline ML48HP230LCMH-O good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 47,500 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the Mainline ML48HP230LCMH-O cost to run per year?
- At its rated efficiency it costs about $1,216-$3,039 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,469 in Phoenix and $2,516 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Mainline ML48HP230LCMH-O?
- ENERGY STAR lists 8 certified combinations for this outdoor unit. The highest-rated ones use MAINLINE ML48HP230FLO-I, MAINLINE ML48HP230STDCAS-I, ML48HP230RS485AHU-I.
- What refrigerant does the Mainline ML48HP230LCMH-O use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 48,000 BTU models
- Blueridge BMS48HHUYC · cold climate18.5 SEER2 · 11.0 HSPF2
- Midea MO1HU-H48B-2A · cold climate18.5 SEER2 · 11.0 HSPF2
- Carrier 38MTRAQ48EA3 · cold climate18.7 SEER2 · 8.8 HSPF2
- Sea Breeze CSZ48H525ZMO · cold climate18.5 SEER2 · 11.0 HSPF2
- Arcoaire DLCMTAH48EAK · cold climate18.7 SEER2 · 8.8 HSPF2
- 1HVAC ACIQ-48ZPL-HP230C · cold climate18.5 SEER2 · 10.8 HSPF2
- Carrier 37MTRAQ48FA3 · cold climate18.7 SEER2 · 9.5 HSPF2
- Cooper&Hunter CH-RHP48LCU-230VO · cold climate18.5 SEER2 · 10.8 HSPF2
See all 146 48,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 19, 2026. How we use the data.