18,000 BTU mini-split heat pump · MTI series
MDV M2OA-18HFN1-M
Average cooling and heating efficiency for a 18,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #167 of 465 18,000 BTU mini-splits for cooling efficiency, and costs about $454 a year to run in a mixed climate like Atlanta.
- SEER2
- 22.9 Cooling efficiency over a seasonAverage · beats 58%
- HSPF2
- 10.5 Heating efficiency over a seasonAverage · beats 61%
- EER2
- 13.9 Cooling efficiency on a 95°F dayVery good · beats 79%
- Heat at 5°F
- 13,300 BTU/h66% of its 47°F outputAverage · beats 48%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 13,300 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 15 certified pairings.
Think twice if…
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | MDV |
| Also sold as | ECO-AIR, Alsetria |
| Outdoor unit model | M2OA-18HFN1-M |
| Series | MTI series |
| Type | Mini-split heat pump |
| Nominal size | 18,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | November 1, 2022 |
| Last certified | June 25, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 22.9 (range 18.0-22.9) |
| EER2Efficiency at 95°F outdoors | 11.5-13.9 |
| Cooling capacity | 18,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.7-10.5 |
| Capacity at 47°F | 18,000-19,000 BTU/h |
| Capacity at 17°F | 14,300-15,200 BTU/h |
| Capacity at 5°F | 12,600-13,300 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.90-2.00 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - | 22.9 | 13.9 | 10.5 | 12,600 | 206714973 |
| - ECO-AIR | 22.9 | 13.9 | 10.5 | 12,600 | 208121868 |
| - Alsetria | 22.9 | 13.9 | 10.5 | 12,600 | 208121905 |
| - | 21.0 | 12.5 | 10.2 | 12,600 | 207641232 |
| - | 21.0 | 13.0 | 10.2 | 12,900 | 206716987 |
| - ECO-AIR | 21.0 | 13.0 | 10.2 | 12,900 | 208121870 |
| - Alsetria | 21.0 | 13.0 | 10.2 | 12,900 | 208121907 |
| - | 20.0 | 12.3 | 10.0 | 12,900 | 207641240 |
| - · cold climate | 19.0 | 12.0 | 9.8 | 13,300 | 207641239 |
| - · cold climate | 19.0 | 12.0 | 9.8 | 13,300 | 206714980 |
| - · cold climate | 19.0 | 12.0 | 9.8 | 13,300 | 213257497 |
| - ECO-AIR · cold climate | 19.0 | 12.0 | 9.8 | 13,300 | 208121869 |
| - Alsetria · cold climate | 19.0 | 12.0 | 9.8 | 13,300 | 208121906 |
| - · cold climate | 18.5 | 11.8 | 9.3 | 13,100 | 213257504 |
| - · cold climate | 18.0 | 11.5 | 8.7 | 13,000 | 213257496 |
Yearly running cost in 10 large cities
- Phoenix, AZ$474/yr
- Miami, FL$371/yr
- Houston, TX$426/yr
- Atlanta, GA$454/yr
- Los Angeles, CA$447/yr
- New York, NY$1,113/yr
- Chicago, IL$909/yr
- Denver, CO$760/yr
- Seattle, WA$471/yr
- Minneapolis, MN$943/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MDV M2OA-18HFN1-M?
- The MDV M2OA-18HFN1-M is rated at up to 22.9 SEER2 and 13.9 EER2 for cooling and up to 10.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 15 certified matchups SEER2 ranges from 18.0-22.9.
- Is the MDV M2OA-18HFN1-M good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 13,300 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the MDV M2OA-18HFN1-M cost to run per year?
- At its rated efficiency it costs about $371-$1,113 a year in electricity in large U.S. cities, depending on climate and local rates - for example $474 in Phoenix and $943 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- What refrigerant does the MDV M2OA-18HFN1-M use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 18,000 BTU models
- Lennox MPC018S4M-1P · cold climate22.9 SEER2 · 10.5 HSPF2
- Midea 38MGRBQ18BA3 · cold climate22.9 SEER2 · 10.5 HSPF2
- DIYCOOL ES-18Z-M2B · cold climate22.9 SEER2 · 10.5 HSPF2
- Midea MMCMRAQ18BA3 · cold climate22.9 SEER2 · 10.5 HSPF2
- DIRECT AIR DIRM-18DA25-2Z · cold climate22.9 SEER2 · 10.5 HSPF2
- Mitsubishi Electric SUZ-KA18NAH222.9 SEER2 · 10.0 HSPF2
- Cooper&Hunter CH-18MES-230VO · cold climate22.9 SEER2 · 10.5 HSPF2
- 1HVAC EZ-18ZPL-HP23022.7 SEER2 · 9.8 HSPF2
See all 465 18,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 25, 2026. How we use the data.