36,000 BTU mini-split heat pump · MSEP seris
MDV M4OG-36HFN1-M-L
Very good cooling efficiency and below average heating efficiency for a 36,000 BTU mini-split heat pump, but not rated for cold climates.
Ranks #23 of 205 36,000 BTU mini-splits for cooling efficiency, and costs about $955 a year to run in a mixed climate like Atlanta.
- SEER2
- 23.9 Cooling efficiency over a seasonVery good · beats 72%
- HSPF2
- 9.3 Heating efficiency over a seasonBelow average · beats 18%
- EER2
- 11.7 Cooling efficiency on a 95°F dayBelow average · beats 16%
- Heat at 5°F
- 25,200 BTU/h68% of its 47°F outputBelow average · beats 9%
A good fit if…
- You want low cooling bills - its SEER2 beats 72% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for mini-splits.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | MDV |
| Outdoor unit model | M4OG-36HFN1-M-L |
| Series | MSEP seris |
| Type | Mini-split heat pump |
| Nominal size | 36,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | November 1, 2022 |
| Last certified | June 25, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 23.9 (range 20.0-23.9) |
| EER2Efficiency at 95°F outdoors | 11.0-11.7 |
| Cooling capacity | 36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.2-9.3 |
| Capacity at 47°F | 37,000 BTU/h |
| Capacity at 17°F | 26,800-27,400 BTU/h |
| Capacity at 5°F | 24,000-25,200 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.68-1.80 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - | 23.9 | 11.7 | 9.3 | 25,200 | 211289829 |
| - | 22.0 | 11.4 | 9.3 | 24,600 | 211289836 |
| - | 20.0 | 11.0 | 9.2 | 24,000 | 211289830 |
Yearly running cost in 10 large cities
- Phoenix, AZ$949/yr
- Miami, FL$715/yr
- Houston, TX$853/yr
- Atlanta, GA$955/yr
- Los Angeles, CA$950/yr
- New York, NY$2,394/yr
- Chicago, IL$1,965/yr
- Denver, CO$1,652/yr
- Seattle, WA$1,029/yr
- Minneapolis, MN$2,052/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MDV M4OG-36HFN1-M-L?
- The MDV M4OG-36HFN1-M-L is rated at up to 23.9 SEER2 and 11.7 EER2 for cooling and up to 9.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 20.0-23.9.
- Is the MDV M4OG-36HFN1-M-L good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 36,000 BTU model.
- How much does the MDV M4OG-36HFN1-M-L cost to run per year?
- At its rated efficiency it costs about $715-$2,394 a year in electricity in large U.S. cities, depending on climate and local rates - for example $949 in Phoenix and $2,052 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- What refrigerant does the MDV M4OG-36HFN1-M-L use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 36,000 BTU models
- Midea MMCMRAQ36DA323.9 SEER2 · 9.5 HSPF2
- TOSOT TMV-V36WL/NHC-T(U) · cold climate23.5 SEER2 · 9.8 HSPF2
- Lennox MPC036S4M-1P23.9 SEER2 · 9.5 HSPF2
- Mitsubishi Electric PUZ-AK36NLHZ2 · cold climate23.3 SEER2 · 10.5 HSPF2
- Kaden KO-PS436HP-2AAMA23.9 SEER2 · 9.5 HSPF2
- Mitsubishi Electric PUZ-AK36NL23.3 SEER2 · 9.8 HSPF2
- Ducane 4DHP2S36M-1P23.9 SEER2 · 9.5 HSPF2
- Mitsubishi Electric PUZ-AK36NL223.3 SEER2 · 9.8 HSPF2
See all 205 36,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 25, 2026. How we use the data.