2.5-ton central heat pump · MVC SERIES
MDV MOD30U-30HFN1-MR0(X)
Very good cooling and heating efficiency for a 2.5-ton central heat pump, and certified for cold climates.
Ranks #35 of 199 2.5 ton central heat pumps for cooling efficiency, and costs about $887 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.2 Cooling efficiency over a seasonVery good · beats 73%
- HSPF2
- 9.7 Heating efficiency over a seasonVery good · beats 77%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 27,000 BTU/h87% of its 47°F outputBelow average · beats 12%
A good fit if…
- You want low cooling bills - its SEER2 beats 73% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 27,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 77% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | MDV |
| Also sold as | ECO-AIR, Alsetria, Midea, CanAir |
| Outdoor unit model | MOD30U-30HFN1-MR0(X) |
| Series | MVC SERIES |
| Type | Central heat pump |
| Nominal size | 2.5 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 1, 2022 |
| Last certified | June 9, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.2 (range 15.2-18.2) |
| EER2Efficiency at 95°F outdoors | 10.0-11.7 |
| Cooling capacity | 28,000-30,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.5-9.7 |
| Capacity at 47°F | 30,000-33,000 BTU/h |
| Capacity at 17°F | 19,600-22,600 BTU/h |
| Capacity at 5°F | 22,600-27,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-1.85 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MVBL-30HWFN1-MJ3 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| MVBL-30HWFN1-MJ3 · cold climate | 18.2 | 11.7 | 8.8 | 26,000 | 213352801 |
| MVBL-30HWFN1-MJ3 · cold climate | 18.2 | 11.7 | 8.8 | 26,000 | 214594893 |
| MVBE-30HWFN1-ML3E · cold climate | 16.9 | 10.0 | 9.0 | 25,000 | 213156950 |
| MVBE-30HWFN1-ML3E · cold climate | 16.9 | 10.0 | 9.0 | 25,000 | 213307909 |
| MVBE-30HWFN1-ML3E · cold climate | 16.9 | 10.0 | 9.0 | 25,000 | 213307911 |
| MVC-30HWFN1-M · cold climate | 16.2 | 10.0 | 8.9 | 24,000 | 207699009 |
| MVC-30HWFN1-M · cold climate | 16.2 | 10.0 | 8.9 | 24,000 | 208130393 |
| MVC-30HWFN1-M · cold climate | 16.2 | 10.0 | 8.9 | 24,000 | 208130404 |
| MAC-36HWDN1-MN0 · cold climate | 15.5 | 10.5 | 9.7 | 27,000 | 208101911 |
| MAC-36HWFN1-M · cold climate | 15.5 | 10.5 | 9.7 | 27,000 | 209550335 |
| MAC-36HWFN1-M · cold climate | 15.5 | 10.5 | 9.7 | 27,000 | 209270321 |
| MAC-36HWDN1-MN0 · cold climate | 15.5 | 10.5 | 9.7 | 27,000 | 214655288 |
| MVB-36B23T4N1 · cold climate | 15.2 | 10.0 | 8.5 | 22,600 | 213301873 |
Yearly running cost in 10 large cities
- Phoenix, AZ$964/yr
- Miami, FL$776/yr
- Houston, TX$865/yr
- Atlanta, GA$887/yr
- Los Angeles, CA$866/yr
- New York, NY$2,134/yr
- Chicago, IL$1,735/yr
- Denver, CO$1,445/yr
- Seattle, WA$890/yr
- Minneapolis, MN$1,789/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MDV MOD30U-30HFN1-MR0(X)?
- The MDV MOD30U-30HFN1-MR0(X) is rated at up to 18.2 SEER2 and 11.7 EER2 for cooling and up to 9.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 13 certified matchups SEER2 ranges from 15.2-18.2.
- Is the MDV MOD30U-30HFN1-MR0(X) good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 27,000 BTU/h at 5°F with a COP of 1.85, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the MDV MOD30U-30HFN1-MR0(X) cost to run per year?
- At its rated efficiency it costs about $776-$2,134 a year in electricity in large U.S. cities, depending on climate and local rates - for example $964 in Phoenix and $1,789 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the MDV MOD30U-30HFN1-MR0(X)?
- ENERGY STAR lists 13 certified combinations for this outdoor unit. The highest-rated ones use MVBL-30HWFN1-MJ3, MVBE-30HWFN1-ML3E, MVC-30HWFN1-M.
- What refrigerant does the MDV MOD30U-30HFN1-MR0(X) use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2.5 ton models
- Innovair SHV30H2R20 · cold climate18.2 SEER2 · 9.7 HSPF2
- Multi MFG HHS-30HD-A · cold climate18.2 SEER2 · 9.0 HSPF2
- ACIQ ACIQ-30-HPB · cold climate18.2 SEER2 · 9.7 HSPF2
- AC Pro AOD30U-30HFN1-MR0(X) · cold climate18.2 SEER2 · 8.8 HSPF2
- TOSOT TUD36-24W2/NHE-D(U) · cold climate18.2 SEER2 · 10.0 HSPF2
- GREE FXE30HP230V1R32AO18.2 SEER2 · 8.3 HSPF2
- GREE GUD36W2/NHE-D(U) · cold climate18.2 SEER2 · 10.0 HSPF2
- GREE FXU36HP230V1R32AO · cold climate18.2 SEER2 · 10.0 HSPF2
See all 199 2.5 ton central heat pumps, ranked