HVAC Rated

4-ton central heat pump · MVB Series

MDV MOX630-60HFN10-M3F

Below average cooling and heating efficiency for a 4-ton central heat pump, and certified for cold climates.

Ranks #243 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,766 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
8.4 Cooling efficiency on a 95°F day
Below average · beats 1%
Heat at 5°F
37,800 BTU/h70% of its 47°F output
Below average · beats 8%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 37,800 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandMDV
Outdoor unit modelMOX630-60HFN10-M3F
SeriesMVB Series
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceApril 15, 2026
Last certifiedJune 29, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 16.0)
EER2Efficiency at 95°F outdoors8.3-8.4
Cooling capacity54,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1
Capacity at 47°F54,000 BTU/h
Capacity at 17°F34,000 BTU/h
Capacity at 5°F37,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.82
ENERGY STAR cold climateYes
Heating output as it gets colder70% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MVBC-60HWFN50-MC3F at the standard test temperatures, in BTU/h:

Certified matchups2 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
MVBC-60HWFN50-MC3F · cold climate16.08.48.137,800218444699
MVBC-60HWFN50-MC3F-D · cold climate16.08.38.137,800218448109
Yearly running cost in 10 large cities$1,586-$4,217

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the MDV MOX630-60HFN10-M3F?
The MDV MOX630-60HFN10-M3F is rated at up to 16.0 SEER2 and 8.4 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the MDV MOX630-60HFN10-M3F good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 37,800 BTU/h at 5°F with a COP of 1.82, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
How much does the MDV MOX630-60HFN10-M3F cost to run per year?
At its rated efficiency it costs about $1,586-$4,217 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,951 in Phoenix and $3,521 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the MDV MOX630-60HFN10-M3F?
ENERGY STAR lists 2 certified combinations for this outdoor unit. The highest-rated ones use MVBC-60HWFN50-MC3F, MVBC-60HWFN50-MC3F-D.
What refrigerant does the MDV MOX630-60HFN10-M3F use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,935/yrYou save $850/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump MDV MOX630-60HFN10-M3F
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,935
Current system, per year
$2,784
You save per year
$850
Payback
24.1 years
Net after 10 years
-$12,003

Cooling $1,188Heating $747Electricity used: 12,092 kWhSaved vs. a minimum-efficiency heat pump: $201

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.