HVAC Rated

2-ton central heat pump · 38Mseries

Midea 38MURAQ24AB3

Average cooling efficiency and very good heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #155 of 331 2 ton central heat pumps for cooling efficiency, and costs about $676 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
10.0 Heating efficiency over a season
Very good · beats 84%
EER2
11.2 Cooling efficiency on a 95°F day
Below average · beats 28%
Heat at 5°F
23,200 BTU/h93% of its 47°F output
Below average · beats 39%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 23,200 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 30 certified pairings.

Think twice if…

  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications2 ton, R-410A
General
BrandMidea
Also sold asCarrier, Bryant, Payne, WeatherMaker, Comfortmaker, Day & Night, Heil, Keeprite, Tempstar, Airquest, Arcoaire
Outdoor unit model38MURAQ24AB3
Series38Mseries
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 1, 2022
Last certifiedJune 4, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 16.1-18.0)
EER2Efficiency at 95°F outdoors10.7-11.7
Cooling capacity24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.5-10.0
Capacity at 47°F24,000-25,000 BTU/h
Capacity at 17°F19,000-22,400 BTU/h
Capacity at 5°F20,000-23,200 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.90-2.00
ENERGY STAR cold climateYes
Heating output as it gets colder93% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with 40MUAAQ30XA3 at the standard test temperatures, in BTU/h:

Certified matchups30 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
40MUAAQ30XA3 · cold climate18.011.29.623,200217197646
40MUAAQ30XA3 · cold climate18.011.29.623,200217197650
40MUAAQ30XA3 · cold climate18.011.29.623,200217197654
40MUAAQ30XA3 · cold climate18.011.29.623,200217197658
40MUAAQ30XA3 · cold climate18.011.29.623,200217197662
40MUAAQ24XA3 · cold climate17.411.710.022,600208447923
40MUAAQ24XA3 · cold climate17.411.710.022,600208447887
40MUAAQ24XA3 · cold climate17.411.710.022,600208447905
40MUAAQ24XA3 · cold climate17.411.710.022,600208447896
40MUAAQ24XA3 · cold climate17.411.710.022,600208447914
DLFUAAH24XAK · cold climate17.411.710.022,600217622221
DLFUAAH24XAK · cold climate17.411.710.022,600217622228
DLFUAAH24XAK · cold climate17.411.710.022,600217622235
DLFUAAH24XAK · cold climate17.411.710.022,600217622242
DLFUAAH24XAK · cold climate17.411.710.022,600217622249
DLFUAAH24XAK · cold climate17.411.710.022,600217622256
DLFUAAH24XAK · cold climate17.411.710.022,600217622263
DLFUAAH24XAK · cold climate17.411.710.022,600217622270
DLFUAAH24XAK · cold climate17.411.710.022,600217622277
DLFUAAH24XAK · cold climate17.411.710.022,600217622214
40MULAQ24XBX + CI · cold climate16.510.79.520,000213372222
40MULAQ24XBX + CI · cold climate16.510.79.520,000213372230
40MULAQ24XBX + CI · cold climate16.510.79.520,000213372238
40MULAQ24XBX + CI · cold climate16.510.79.520,000213372206
40MULAQ24XBX + CI · cold climate16.510.79.520,000213372214
40MULAQ24XAX + CI · cold climate16.110.79.820,000213372237
40MULAQ24XAX + CI · cold climate16.110.79.820,000213372221
40MULAQ24XAX + CI · cold climate16.110.79.820,000213372229
40MULAQ24XAX + CI · cold climate16.110.79.820,000213372205
40MULAQ24XAX + CI · cold climate16.110.79.820,000213372213
Yearly running cost in 10 large cities$625-$1,598

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Midea 38MURAQ24AB3?
The Midea 38MURAQ24AB3 is rated at up to 18.0 SEER2 and 11.2 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 30 certified matchups SEER2 ranges from 16.1-18.0.
Is the Midea 38MURAQ24AB3 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 23,200 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Midea 38MURAQ24AB3 cost to run per year?
At its rated efficiency it costs about $625-$1,598 a year in electricity in large U.S. cities, depending on climate and local rates - for example $761 in Phoenix and $1,327 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Midea 38MURAQ24AB3?
ENERGY STAR lists 30 certified combinations for this outdoor unit. The highest-rated ones use 40MUAAQ30XA3, 40MUAAQ24XA3, DLFUAAH24XAK.
What refrigerant does the Midea 38MURAQ24AB3 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $749/yrYou save $505/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Midea 38MURAQ24AB3
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$749
Current system, per year
$1,254
You save per year
$505
Payback
17.8 years
Net after 10 years
-$3,955

Cooling $469Heating $280Electricity used: 4,683 kWhSaved vs. a minimum-efficiency heat pump: $215

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 4, 2026. How we use the data.