2-ton central heat pump · ATOM X
Midea MDV-V24WMN10T
Very good cooling and heating efficiency for a 2-ton central heat pump, and certified for cold climates.
Ranks #92 of 331 2 ton central heat pumps for cooling efficiency, and costs about $641 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.5 Cooling efficiency over a seasonVery good · beats 77%
- HSPF2
- 10.0 Heating efficiency over a seasonVery good · beats 84%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 20,000 BTU/h77% of its 47°F outputBelow average · beats 20%
A good fit if…
- You want low cooling bills - its SEER2 beats 77% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 20,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Midea |
| Outdoor unit model | MDV-V24WMN10T |
| Series | ATOM X |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | November 15, 2024 |
| Last certified | April 22, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.5 (range 16.0-18.5) |
| EER2Efficiency at 95°F outdoors | 10.0-11.7 |
| Cooling capacity | 22,000-24,400 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.5-10.0 |
| Capacity at 47°F | 24,000-26,000 BTU/h |
| Capacity at 17°F | 17,600-18,400 BTU/h |
| Capacity at 5°F | 19,200-20,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-1.90 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| - MIDEA · cold climate | - | 18.5 | 11.7 | 10.0 | 20,000 | 216021073 |
| - MIDEA · cold climate | - | 17.8 | 11.7 | 9.5 | 20,000 | 216021074 |
| MVME24B2MN10TB · cold climate | - | 17.7 | 11.7 | 9.2 | 20,000 | 216051342 |
| MIH24VMN10 · cold climate | - | 17.0 | 11.7 | 9.2 | 20,000 | 216441715 |
| - MIDEA · cold climate | - | 17.0 | 11.7 | 9.0 | 20,000 | 216021058 |
| MCPM3036BN10TH · cold climate | MGV96U080B3C | 16.0 | 10.1 | 8.9 | 20,000 | 216046592 |
| MCPM3036BN10TH · cold climate | MGV96U060B3C | 16.0 | 10.1 | 8.6 | 20,000 | 216054429 |
| MPCE24A1MN10TA · cold climate | - | 16.0 | 10.0 | 8.5 | 19,200 | 216440559 |
| MPUE24A1MN10TA · cold climate | - | 16.0 | 10.0 | 8.5 | 19,200 | 216505545 |
Yearly running cost in 10 large cities
- Phoenix, AZ$715/yr
- Miami, FL$584/yr
- Houston, TX$640/yr
- Atlanta, GA$641/yr
- Los Angeles, CA$623/yr
- New York, NY$1,525/yr
- Chicago, IL$1,236/yr
- Denver, CO$1,027/yr
- Seattle, WA$630/yr
- Minneapolis, MN$1,270/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Midea MDV-V24WMN10T?
- The Midea MDV-V24WMN10T is rated at up to 18.5 SEER2 and 11.7 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 9 certified matchups SEER2 ranges from 16.0-18.5.
- Is the Midea MDV-V24WMN10T good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 20,000 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the Midea MDV-V24WMN10T cost to run per year?
- At its rated efficiency it costs about $584-$1,525 a year in electricity in large U.S. cities, depending on climate and local rates - for example $715 in Phoenix and $1,270 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Midea MDV-V24WMN10T?
- ENERGY STAR lists 9 certified combinations for this outdoor unit. The highest-rated ones use MVME24B2MN10TB, MIH24VMN10, MCPM3036BN10TH.
- What refrigerant does the Midea MDV-V24WMN10T use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Lennox EL18KSLV-024-230A · cold climate18.5 SEER2 · 10.0 HSPF2
- Haier 1U24T3PS*HE · cold climate18.5 SEER2 · 10.0 HSPF2
- UTL UCHA-24HDCSN2 · cold climate18.5 SEER2 · 9.5 HSPF2
- GE Appliances NS18H24HA5 · cold climate18.5 SEER2 · 10.0 HSPF2
- UTL UCHA-24HDCSN4 · cold climate18.5 SEER2 · 9.5 HSPF2
- Concord 7SCP18V24P-**A · cold climate18.5 SEER2 · 10.0 HSPF2
- VillaTherm VHPSD-UCHA-24HDCSN · cold climate18.5 SEER2 · 9.5 HSPF2
- Armstrong Air A7SCP18V24P-**A · cold climate18.5 SEER2 · 10.0 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of April 22, 2026. How we use the data.