HVAC Rated

48,000 BTU mini-split heat pump · R series

Mitsubishi Electric RUZ-AK48NL

Below average cooling and heating efficiency for a 48,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #146 of 146 48,000 BTU mini-splits for cooling efficiency, and costs about $1,438 a year to run in a mixed climate like Atlanta.

SEER2
16.2 Cooling efficiency over a season
Below average · beats 0%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 2%
EER2
9.9 Cooling efficiency on a 95°F day
Below average · beats 4%
Heat at 5°F
32,000 BTU/h70% of its 47°F output
Very good · beats 83%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 32,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.
  • You mainly need heat - its HSPF2 is below average for mini-splits.

Calculate my running cost

Details

Specifications48,000 BTU, R-454B
General
BrandMitsubishi Electric
Outdoor unit modelRUZ-AK48NL
SeriesR series
TypeMini-split heat pump
Nominal size48,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceSeptember 1, 2026
Last certifiedJuly 17, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.2 (range 16.2)
EER2Efficiency at 95°F outdoors9.9
Cooling capacity45,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5
Capacity at 47°F45,500 BTU/h
Capacity at 17°F33,200 BTU/h
Capacity at 5°F32,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.24
ENERGY STAR cold climateYes
Heating output as it gets colder70% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with RVZ-AP48NL at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
RVZ-AP48NL · cold climate16.29.98.532,000218680157
Yearly running cost in 10 large cities$1,318-$3,410

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Mitsubishi Electric RUZ-AK48NL?
The Mitsubishi Electric RUZ-AK48NL is rated at up to 16.2 SEER2 and 9.9 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Mitsubishi Electric RUZ-AK48NL good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 32,000 BTU/h at 5°F with a COP of 2.24, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
How much does the Mitsubishi Electric RUZ-AK48NL cost to run per year?
At its rated efficiency it costs about $1,318-$3,410 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,609 in Phoenix and $2,836 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Mitsubishi Electric RUZ-AK48NL?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses RVZ-AP48NL.
What refrigerant does the Mitsubishi Electric RUZ-AK48NL use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,588/yrYou save $758/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Mitsubishi Electric RUZ-AK48NL
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,588
Current system, per year
$2,346
You save per year
$758
Payback
22.4 years
Net after 10 years
-$9,421

Cooling $989Heating $600Electricity used: 9,926 kWhSaved vs. a minimum-efficiency heat pump: $211

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 48,000 BTU models

See all 146 48,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 17, 2026. How we use the data.