HVAC Rated

15,000 BTU mini-split heat pump · M series

Mitsubishi Electric SUZ-AA15NL

Below average cooling efficiency and average heating efficiency for a 15,000 BTU mini-split heat pump, but not rated for cold climates.

Ranks #42 of 62 15,000 BTU mini-splits for cooling efficiency, and costs about $422 a year to run in a mixed climate like Atlanta.

SEER2
20.9 Cooling efficiency over a season
Below average · beats 26%
HSPF2
10.6 Heating efficiency over a season
Average · beats 65%
EER2
12.1 Cooling efficiency on a 95°F day
Below average · beats 31%
Heat at 5°F
9,900 BTU/h55% of its 47°F output
Excellent · beats 100%

A good fit if…

  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 10 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for mini-splits.

Calculate my running cost

Details

Specifications15,000 BTU, R-454B
General
BrandMitsubishi Electric
Outdoor unit modelSUZ-AA15NL
SeriesM series
TypeMini-split heat pump
Nominal size15,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceFebruary 3, 2025
Last certifiedJune 13, 2026
Cooling
SEER2Seasonal efficiency, higher is better20.9 (range 18.8-20.9)
EER2Efficiency at 95°F outdoors12.0-13.2
Cooling capacity15,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.7-10.6
Capacity at 47°F15,000-18,000 BTU/h
Capacity at 17°F10,200-11,300 BTU/h
Capacity at 5°F9,600-9,900 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-3.00
ENERGY STAR cold climateNo
Heating output as it gets colder55% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MSZ-EX15NLS at the standard test temperatures, in BTU/h:

Certified matchups10 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
MSZ-EX15NLS20.912.110.69,900215748504
MSZ-EX15NLB20.912.110.69,900215748501
MSZ-EX15NLW20.912.110.69,900215748506
MSZ-EX15NL2W20.912.110.69,900218597413
MSZ-EX15NL2S20.912.110.69,900218597412
MSZ-EX15NL2B20.912.110.69,900218597411
SLZ-AF15NL20.612.010.19,600215734901
MFZ-KX15NL20.113.010.59,800215734902
SEZ-AD15NL19.113.29.89,700217232156
PEAD-AA15NL18.812.29.79,600215734903
Yearly running cost in 10 large cities$339-$1,040

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Mitsubishi Electric SUZ-AA15NL?
The Mitsubishi Electric SUZ-AA15NL is rated at up to 20.9 SEER2 and 12.1 EER2 for cooling and up to 10.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 10 certified matchups SEER2 ranges from 18.8-20.9.
Is the Mitsubishi Electric SUZ-AA15NL good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 15,000 BTU model.
How much does the Mitsubishi Electric SUZ-AA15NL cost to run per year?
At its rated efficiency it costs about $339-$1,040 a year in electricity in large U.S. cities, depending on climate and local rates - for example $437 in Phoenix and $883 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Mitsubishi Electric SUZ-AA15NL?
ENERGY STAR lists 10 certified combinations for this outdoor unit. The highest-rated ones use MSZ-EX15NLS, MSZ-EX15NLB, MSZ-EX15NLW.
What refrigerant does the Mitsubishi Electric SUZ-AA15NL use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $443/yrYou save $380/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Mitsubishi Electric SUZ-AA15NL
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$443
Current system, per year
$823
You save per year
$380
Payback
14.5 years
Net after 10 years
-$1,703

Cooling $253Heating $190Electricity used: 2,768 kWhSaved vs. a minimum-efficiency heat pump: $195

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 15,000 BTU models

See all 62 15,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 13, 2026. How we use the data.