HVAC Rated

9,000 BTU mini-split heat pump · CS-XE9WKUAW / CU-XE9WKUA

Panasonic CU-XE9WKUA

Excellent cooling efficiency and very good heating efficiency for a 9,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #79 of 395 9,000 BTU mini-splits for cooling efficiency, and costs about $213 a year to run in a mixed climate like Atlanta.

SEER2
27.3 Cooling efficiency over a season
Excellent · beats 95%
HSPF2
12.0 Heating efficiency over a season
Very good · beats 89%
EER2
16.1 Cooling efficiency on a 95°F day
Excellent · beats 96%
Heat at 5°F
9,700 BTU/h89% of its 47°F output
Average · beats 61%

A good fit if…

  • You want low cooling bills - its SEER2 beats 95% of mini-splits.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 9,700 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 89% of mini-splits.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications9,000 BTU, R-410A
General
BrandPanasonic
Outdoor unit modelCU-XE9WKUA
SeriesCS-XE9WKUAW / CU-XE9WKUA
TypeMini-split heat pump
Nominal size9,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceFebruary 1, 2020
Last certifiedOctober 5, 2023
Cooling
SEER2Seasonal efficiency, higher is better27.3 (range 27.3)
EER2Efficiency at 95°F outdoors16.1
Cooling capacity8,700 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better12.0
Capacity at 47°F10,900 BTU/h
Capacity at 17°F- BTU/h
Capacity at 5°F9,700 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.06
ENERGY STAR cold climateYes
Heating output as it gets colder89% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CU-XE9WKUA at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
CU-XE9WKUA · cold climate27.316.112.09,700205047851
Yearly running cost in 10 large cities$152-$541

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Panasonic CU-XE9WKUA?
The Panasonic CU-XE9WKUA is rated at up to 27.3 SEER2 and 16.1 EER2 for cooling and up to 12.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Panasonic CU-XE9WKUA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 9,700 BTU/h at 5°F with a COP of 2.06, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the Panasonic CU-XE9WKUA cost to run per year?
At its rated efficiency it costs about $152-$541 a year in electricity in large U.S. cities, depending on climate and local rates - for example $206 in Phoenix and $466 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Panasonic CU-XE9WKUA?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses CU-XE9WKUA.
What refrigerant does the Panasonic CU-XE9WKUA use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $214/yrYou save $271/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Panasonic CU-XE9WKUA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$214
Current system, per year
$485
You save per year
$271
Payback
12.9 years
Net after 10 years
-$793

Cooling $112Heating $102Electricity used: 1,337 kWhSaved vs. a minimum-efficiency heat pump: $163

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 9,000 BTU models

See all 395 9,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 5, 2023. How we use the data.