2-ton central heat pump · W Series
Rheem WP15AY24AJ2N
Below average cooling and heating efficiency for a 2-ton central heat pump, but not rated for cold climates.
Ranks #328 of 331 2 ton central heat pumps for cooling efficiency, and costs about $774 a year to run in a mixed climate like Atlanta.
- SEER2
- 15.2 Cooling efficiency over a seasonBelow average · beats 6%
- HSPF2
- 7.8 Heating efficiency over a seasonBelow average · beats 5%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 11,200 BTU/h48% of its 47°F outputAverage · beats 58%
A good fit if…
- You want a choice of indoor units - 11 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
Details
Specifications
| General | |
|---|---|
| Brand | Rheem |
| Also sold as | Ruud, WeatherKing, Fujitsu |
| Outdoor unit model | WP15AY24AJ2N |
| Series | W Series |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Two-stage |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | August 6, 2024 |
| Last certified | January 31, 2025 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 15.2 (range 15.2) |
| EER2Efficiency at 95°F outdoors | 11.7 |
| Cooling capacity | 22,800 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8 |
| Capacity at 47°F | 22,600-22,800 BTU/h |
| Capacity at 17°F | 13,800-22,600 BTU/h |
| Capacity at 5°F | 10,900-11,200 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00-2.10 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with WH2TY2417STANN at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| FHRNTT2417S*YTNA | - | 15.2 | 11.7 | 7.8 | - | 215415493 |
| WH2TY2417STANN | - | 15.2 | 11.7 | 7.8 | 10,900 | 215415451 |
| RH2TY2417STANN | - | 15.2 | 11.7 | 7.8 | 10,900 | 215415459 |
| RH2TY2417STANN | - | 15.2 | 11.7 | 7.8 | 10,900 | 215415460 |
| RCFY2417STANM | U97MV0703A17DHS | 15.2 | 11.7 | 7.8 | 11,100 | 215654520 |
| RCFY2417STANM | U98MV0703A17UPS | 15.2 | 11.7 | 7.8 | 11,100 | 215654553 |
| RCFY2417STANM | R98MV0703A17UP | 15.2 | 11.7 | 7.8 | 11,100 | 215654561 |
| RCFY2417STANM | R97MV0703A17DH | 15.2 | 11.7 | 7.8 | 11,100 | 215654565 |
| RF2TY2421STANS | - | 15.2 | 11.7 | 7.8 | 11,200 | 216533437 |
| RF2TY2421STANS | - | 15.2 | 11.7 | 7.8 | 11,200 | 216533427 |
| RF2TY2421STANS | - | 15.2 | 11.7 | 7.8 | 11,200 | 216533434 |
Yearly running cost in 10 large cities
- Phoenix, AZ$862/yr
- Miami, FL$704/yr
- Houston, TX$773/yr
- Atlanta, GA$774/yr
- Los Angeles, CA$752/yr
- New York, NY$1,841/yr
- Chicago, IL$1,493/yr
- Denver, CO$1,239/yr
- Seattle, WA$760/yr
- Minneapolis, MN$1,533/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Rheem WP15AY24AJ2N?
- The Rheem WP15AY24AJ2N is rated at up to 15.2 SEER2 and 11.7 EER2 for cooling and up to 7.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Rheem WP15AY24AJ2N good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
- How much does the Rheem WP15AY24AJ2N cost to run per year?
- At its rated efficiency it costs about $704-$1,841 a year in electricity in large U.S. cities, depending on climate and local rates - for example $862 in Phoenix and $1,533 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Rheem WP15AY24AJ2N?
- ENERGY STAR lists 11 certified combinations for this outdoor unit. The highest-rated ones use FHRNTT2417S*YTNA, WH2TY2417STANN, RH2TY2417STANN.
- What refrigerant does the Rheem WP15AY24AJ2N use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- OXBOX J5HP5024A1000AA15.2 SEER2 · 7.8 HSPF2
- Ruud RP15AY24AJ2N15.2 SEER2 · 7.8 HSPF2
- Midea MOVA-24HN10-M152L15.2 SEER2 · 7.8 HSPF2
- Sure SP15AY24AJ2N15.2 SEER2 · 7.8 HSPF2
- Kaden KOVH-24BAM152L15.2 SEER2 · 7.8 HSPF2
- Whirlpool WLP15AY24AJ2N15.2 SEER2 · 7.8 HSPF2
- Guardian RHP15024B2115.2 SEER2 · 7.8 HSPF2
- Fujitsu FOP1524TJAYNA15.2 SEER2 · 7.8 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 31, 2025. How we use the data.