24,000 BTU mini-split heat pump · CASSETTE-single
ROVSUN RVC-24/O
Average cooling and heating efficiency for a 24,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #132 of 430 24,000 BTU mini-splits for cooling efficiency, and costs about $599 a year to run in a mixed climate like Atlanta.
- SEER2
- 22.5 Cooling efficiency over a seasonAverage · beats 56%
- HSPF2
- 10.4 Heating efficiency over a seasonAverage · beats 57%
- EER2
- 11.7 Cooling efficiency on a 95°F dayBelow average · beats 16%
- Heat at 5°F
- 19,100 BTU/h76% of its 47°F outputAverage · beats 48%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 19,100 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | ROVSUN |
| Also sold as | GARVEE |
| Outdoor unit model | RVC-24/O |
| Series | CASSETTE-single |
| Type | Mini-split heat pump |
| Nominal size | 24,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | August 16, 2025 |
| Last certified | January 14, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 22.5 (range 22.5) |
| EER2Efficiency at 95°F outdoors | 11.7 |
| Cooling capacity | 23,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.4 |
| Capacity at 47°F | 25,000 BTU/h |
| Capacity at 17°F | 22,000 BTU/h |
| Capacity at 5°F | 19,100 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with RVC-24/I at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| RVC-24/I Rovsun · cold climate | 22.5 | 11.7 | 10.4 | 19,100 | 217893997 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the ROVSUN RVC-24/O: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- GARVEE GMSC24-A
Yearly running cost in 10 large cities
- Phoenix, AZ$621/yr
- Miami, FL$483/yr
- Houston, TX$557/yr
- Atlanta, GA$599/yr
- Los Angeles, CA$590/yr
- New York, NY$1,474/yr
- Chicago, IL$1,205/yr
- Denver, CO$1,008/yr
- Seattle, WA$625/yr
- Minneapolis, MN$1,250/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the ROVSUN RVC-24/O?
- The ROVSUN RVC-24/O is rated at up to 22.5 SEER2 and 11.7 EER2 for cooling and up to 10.4 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the ROVSUN RVC-24/O good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 19,100 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the ROVSUN RVC-24/O cost to run per year?
- At its rated efficiency it costs about $483-$1,474 a year in electricity in large U.S. cities, depending on climate and local rates - for example $621 in Phoenix and $1,250 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the ROVSUN RVC-24/O the same as the GARVEE GMSC24-A?
- Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the ROVSUN RVC-24/O?
- ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses Rovsun RVC-24/I.
- What refrigerant does the ROVSUN RVC-24/O use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 24,000 BTU models
- Fujitsu AOUH24LMAS1 · cold climate22.5 SEER2 · 11.4 HSPF2
- DELLA 048-TPH-24K2V-23S-OUT · cold climate22.5 SEER2 · 10.0 HSPF2
- Mitsubishi Electric PUZ-AH24NL2 · cold climate22.6 SEER2 · 9.8 HSPF2
- MDV M3OX430-27HFN8-M1 · cold climate22.5 SEER2 · 10.0 HSPF2
- Mitsubishi Electric PUZ-AH24NL22.6 SEER2 · 9.8 HSPF2
- TCL TSH24HEI2NAN0T24U · cold climate22.5 SEER2 · 10.0 HSPF2
- MRCOOL DIYP-24-HP-C-230DE11-O22.7 SEER2 · 9.5 HSPF2
- ZERO ZMSB-24HVT-USHHCR2 · cold climate22.5 SEER2 · 10.0 HSPF2
See all 430 24,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 14, 2026. How we use the data.