9,000 BTU mini-split heat pump · Bespoke AI WindFree (RAC)
Samsung AR60H09C1JWX
Below average cooling and heating efficiency for a 9,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #323 of 395 9,000 BTU mini-splits for cooling efficiency, and costs about $287 a year to run in a mixed climate like Atlanta.
- SEER2
- 21.0 Cooling efficiency over a seasonBelow average · beats 30%
- HSPF2
- 9.0 Heating efficiency over a seasonBelow average · beats 10%
- EER2
- 15.0 Cooling efficiency on a 95°F dayExcellent · beats 91%
- Heat at 5°F
- 8,500 BTU/h77% of its 47°F outputBelow average · beats 31%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 8,500 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for mini-splits.
- You mainly need heat - its HSPF2 is below average for mini-splits.
Details
Specifications
| General | |
|---|---|
| Brand | Samsung |
| Outdoor unit model | AR60H09C1JWX |
| Series | Bespoke AI WindFree (RAC) |
| Type | Mini-split heat pump |
| Nominal size | 9,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-32 |
| Connected (smart) capable | No |
| On the market since | September 11, 2026 |
| Last certified | July 29, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 21.0 (range 21.0) |
| EER2Efficiency at 95°F outdoors | 15.0 |
| Cooling capacity | 9,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.0 |
| Capacity at 47°F | 11,000 BTU/h |
| Capacity at 17°F | 10,000 BTU/h |
| Capacity at 5°F | 8,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.91 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with AR60H09C1JWN at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| AR60H09C1JWN SAMSUNG · cold climate | 21.0 | 15.0 | 9.0 | 8,500 | 218691691 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the Samsung AR60H09C1JWX: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- Samsung MWHE009S6S-1P
Yearly running cost in 10 large cities
- Phoenix, AZ$277/yr
- Miami, FL$204/yr
- Houston, TX$249/yr
- Atlanta, GA$287/yr
- Los Angeles, CA$287/yr
- New York, NY$727/yr
- Chicago, IL$599/yr
- Denver, CO$504/yr
- Seattle, WA$315/yr
- Minneapolis, MN$627/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Samsung AR60H09C1JWX?
- The Samsung AR60H09C1JWX is rated at up to 21.0 SEER2 and 15.0 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Samsung AR60H09C1JWX good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 8,500 BTU/h at 5°F with a COP of 1.91, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the Samsung AR60H09C1JWX cost to run per year?
- At its rated efficiency it costs about $204-$727 a year in electricity in large U.S. cities, depending on climate and local rates - for example $277 in Phoenix and $627 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Samsung AR60H09C1JWX the same as the Samsung MWHE009S6S-1P?
- Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the Samsung AR60H09C1JWX?
- ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses SAMSUNG AR60H09C1JWN.
- What refrigerant does the Samsung AR60H09C1JWX use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 9,000 BTU models
- LG KUSAD091A · cold climate21.0 SEER2 · 9.2 HSPF2
- AC Pro AOX330-09HFN1-MY5W · cold climate20.5 SEER2 · 10.3 HSPF2
- LG KUSAC091A · cold climate21.0 SEER2 · 9.2 HSPF2
- Hitachi RAC-SH09WHLAE20.5 SEER2 · 10.3 HSPF2
- TCL H09SAH21XQC · cold climate21.0 SEER2 · 9.5 HSPF2
- Friedrich FPHFR09A3A · cold climate20.5 SEER2 · 10.0 HSPF2
- MDV MOX130-09HFN8-M1L · cold climate21.0 SEER2 · 10.0 HSPF2
- Hitachi RAS-1.0PNNBDH1 · cold climate20.5 SEER2 · 10.0 HSPF2
See all 395 9,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 29, 2026. How we use the data.