HVAC Rated

6,000 BTU mini-split heat pump · SAK Series

Star Air Kontrol SAK-06-DT2/220V

Below average cooling efficiency and excellent heating efficiency for a 6,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #42 of 42 6,000 BTU mini-splits for cooling efficiency, and costs about $156 a year to run in a mixed climate like Atlanta.

SEER2
21.4 Cooling efficiency over a season
Below average · beats 36%
HSPF2
13.8 Heating efficiency over a season
Excellent · beats 97%
EER2
14.4 Cooling efficiency on a 95°F day
Very good · beats 87%
Heat at 5°F
7,800 BTU/h98% of its 47°F output
Excellent · beats 93%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 7,800 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 97% of mini-splits.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for mini-splits.

Calculate my running cost

Details

Specifications6,000 BTU, R-454B
General
BrandStar Air Kontrol
Outdoor unit modelSAK-06-DT2/220V
SeriesSAK Series
TypeMini-split heat pump
Nominal size6,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceOctober 28, 2024
Last certifiedMarch 4, 2025
Cooling
SEER2Seasonal efficiency, higher is better21.4 (range 21.4)
EER2Efficiency at 95°F outdoors14.4
Cooling capacity6,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better13.8
Capacity at 47°F8,000 BTU/h
Capacity at 17°F8,000 BTU/h
Capacity at 5°F7,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.40
ENERGY STAR cold climateYes
Heating output as it gets colder98% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with SAK-06-DT1/220V at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
SAK-06-DT1/220V · cold climate21.414.413.87,800216369214
Yearly running cost in 10 large cities$143-$369

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Star Air Kontrol SAK-06-DT2/220V?
The Star Air Kontrol SAK-06-DT2/220V is rated at up to 21.4 SEER2 and 14.4 EER2 for cooling and up to 13.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Star Air Kontrol SAK-06-DT2/220V good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 7,800 BTU/h at 5°F with a COP of 2.40, so it is still 2.4 times as efficient as electric resistance heat at that temperature.
How much does the Star Air Kontrol SAK-06-DT2/220V cost to run per year?
At its rated efficiency it costs about $143-$369 a year in electricity in large U.S. cities, depending on climate and local rates - for example $174 in Phoenix and $307 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Star Air Kontrol SAK-06-DT2/220V?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses SAK-06-DT1/220V.
What refrigerant does the Star Air Kontrol SAK-06-DT2/220V use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $172/yrYou save $188/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Star Air Kontrol SAK-06-DT2/220V
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$172
Current system, per year
$360
You save per year
$188
Payback
13.3 years
Net after 10 years
-$621

Cooling $107Heating $65Electricity used: 1,074 kWhSaved vs. a minimum-efficiency heat pump: $108

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 6,000 BTU models

See all 42 6,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of March 4, 2025. How we use the data.