12,000 BTU mini-split heat pump · SAK Series
Star Air Kontrol SAK-12-22MS/110
Average cooling and heating efficiency for a 12,000 BTU mini-split heat pump, but not rated for cold climates.
Ranks #274 of 394 12,000 BTU mini-splits for cooling efficiency, and costs about $302 a year to run in a mixed climate like Atlanta.
- SEER2
- 22.7 Cooling efficiency over a seasonAverage · beats 57%
- HSPF2
- 10.0 Heating efficiency over a seasonAverage · beats 43%
- EER2
- 12.5 Cooling efficiency on a 95°F dayAverage · beats 44%
- Heat at 5°F
- 6,500 BTU/h54% of its 47°F outputAverage · beats 48%
A good fit if…
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Star Air Kontrol |
| Also sold as | KANIONco, Pioneer |
| Outdoor unit model | SAK-12-22MS/110 |
| Series | SAK Series |
| Type | Mini-split heat pump |
| Nominal size | 12,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | April 28, 2024 |
| Last certified | April 17, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 22.7 (range 22.7) |
| EER2Efficiency at 95°F outdoors | 12.5 |
| Cooling capacity | 12,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.0 |
| Capacity at 47°F | 12,000 BTU/h |
| Capacity at 17°F | 8,400 BTU/h |
| Capacity at 5°F | 6,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with SAK-12-22MS/110 at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| SAK-12-22MS/110 | 22.7 | 12.5 | 10.0 | 6,500 | 211504104 |
Same unit, other model numbers
Yearly running cost in 10 large cities
- Phoenix, AZ$318/yr
- Miami, FL$250/yr
- Houston, TX$285/yr
- Atlanta, GA$302/yr
- Los Angeles, CA$297/yr
- New York, NY$740/yr
- Chicago, IL$604/yr
- Denver, CO$505/yr
- Seattle, WA$312/yr
- Minneapolis, MN$626/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Star Air Kontrol SAK-12-22MS/110?
- The Star Air Kontrol SAK-12-22MS/110 is rated at up to 22.7 SEER2 and 12.5 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the Star Air Kontrol SAK-12-22MS/110 good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 12,000 BTU model.
- How much does the Star Air Kontrol SAK-12-22MS/110 cost to run per year?
- At its rated efficiency it costs about $250-$740 a year in electricity in large U.S. cities, depending on climate and local rates - for example $318 in Phoenix and $626 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the Star Air Kontrol SAK-12-22MS/110 the same as the KANIONco KWSM-12IR410AHS21.5MVL?
- Yes, as far as the certified ratings go. ENERGY STAR lists 3 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the Star Air Kontrol SAK-12-22MS/110?
- ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses SAK-12-22MS/110.
- What refrigerant does the Star Air Kontrol SAK-12-22MS/110 use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 12,000 BTU models
- TGM MRSVHT12AS · cold climate22.7 SEER2 · 10.3 HSPF2
- Pioneer YN012GMFI22RPE · cold climate22.7 SEER2 · 10.3 HSPF2
- LG KUSAB121A · cold climate22.5 SEER2 · 10.5 HSPF2
- Lennox LISH012000P431-D · cold climate22.7 SEER2 · 10.3 HSPF2
- Deye DWA4-12KR2(US)22.5 SEER2 · 9.7 HSPF2
- C&H CH-ES12-115VO22.7 SEER2 · 10.4 HSPF2
- HAVELLS GHS12H5MWAHD05 · cold climate22.5 SEER2 · 9.7 HSPF2
- AI AIR CONDITIONING AO24-12N1-B1H22.7 SEER2 · 10.4 HSPF2
See all 394 12,000 BTU mini-splits, ranked