HVAC Rated

12,000 BTU mini-split heat pump · T-PRO

TCL TSH12HDI1NAN0T23

Average cooling efficiency and below average heating efficiency for a 12,000 BTU mini-split heat pump, but not rated for cold climates.

Ranks #266 of 394 12,000 BTU mini-splits for cooling efficiency, and costs about $312 a year to run in a mixed climate like Atlanta.

SEER2
23.0 Cooling efficiency over a season
Average · beats 62%
HSPF2
9.5 Heating efficiency over a season
Below average · beats 24%
EER2
13.0 Cooling efficiency on a 95°F day
Average · beats 62%
Heat at 5°F
9,000 BTU/h75% of its 47°F output
Below average · beats 9%

A good fit if…

  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for mini-splits.

Calculate my running cost

Details

Specifications12,000 BTU, R-32
General
BrandTCL
Outdoor unit modelTSH12HDI1NAN0T23
SeriesT-PRO
TypeMini-split heat pump
Nominal size12,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceDecember 13, 2024
Last certifiedJuly 24, 2025
Cooling
SEER2Seasonal efficiency, higher is better23.0 (range 23.0)
EER2Efficiency at 95°F outdoors13.0
Cooling capacity12,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.5
Capacity at 47°F12,000 BTU/h
Capacity at 17°F7,500 BTU/h
Capacity at 5°F9,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80
ENERGY STAR cold climateNo
Heating output as it gets colder75% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TSH12IDI1NAN0T23 at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
TSH12IDI1NAN0T2323.013.09.59,000212524535
Yearly running cost in 10 large cities$247-$771

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the TCL TSH12HDI1NAN0T23?
The TCL TSH12HDI1NAN0T23 is rated at up to 23.0 SEER2 and 13.0 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the TCL TSH12HDI1NAN0T23 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 12,000 BTU model.
How much does the TCL TSH12HDI1NAN0T23 cost to run per year?
At its rated efficiency it costs about $247-$771 a year in electricity in large U.S. cities, depending on climate and local rates - for example $320 in Phoenix and $656 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the TCL TSH12HDI1NAN0T23?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses TSH12IDI1NAN0T23.
What refrigerant does the TCL TSH12HDI1NAN0T23 use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $325/yrYou save $294/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump TCL TSH12HDI1NAN0T23
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$325
Current system, per year
$619
You save per year
$294
Payback
15.3 years
Net after 10 years
-$1,564

Cooling $184Heating $141Electricity used: 2,032 kWhSaved vs. a minimum-efficiency heat pump: $149

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 12,000 BTU models

See all 394 12,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 24, 2025. How we use the data.