HVAC Rated

5-ton central heat pump · SmartSense 23 VS HP

Tempstar B5H3V60*K*AAA

Excellent cooling efficiency and average heating efficiency for a 5-ton central heat pump, and certified for cold climates.

Ranks #5 of 100 5 ton central heat pumps for cooling efficiency, and costs about $1,668 a year to run in a mixed climate like Atlanta.

SEER2
20.0 Cooling efficiency over a season
Excellent · beats 94%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
12.5 Cooling efficiency on a 95°F day
Very good · beats 80%
Heat at 5°F
47,500 BTU/h74% of its 47°F output
Very good · beats 71%

A good fit if…

  • You want low cooling bills - its SEER2 beats 94% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 47,500 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 306 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications5 ton, R-454B
General
BrandTempstar
Also sold asKenmore, Keeprite, Day & Night, Comfortmaker, Arcoaire, Airquest, Heil, ACIQ
Outdoor unit modelB5H3V60*K*AAA
SeriesSmartSense 23 VS HP
TypeCentral heat pump
Nominal size5 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceNovember 1, 2024
Last certifiedJuly 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better20.0 (range 17.5-20.0)
EER2Efficiency at 95°F outdoors10.5-12.5
Cooling capacity55,000-58,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.0-9.0
Capacity at 47°F60,000-61,000 BTU/h
Capacity at 17°F46,000-49,000 BTU/h
Capacity at 5°F44,500-47,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.96-2.18
ENERGY STAR cold climateYes
Heating output as it gets colder74% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FCMA5B60L0D*+WALLCON at the standard test temperatures, in BTU/h:

Certified matchups306 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 306 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FCMA5B60L0D*+WALLCON · cold climate-20.012.59.044,500218405903
FCMA5B60L0D*+WALLCON · cold climate-20.012.59.044,500218405902
FCMA5B60L0D*+WALLCON · cold climate-20.012.59.044,500218405901
FCMA5B60L0D*+WALLCON · cold climate-20.012.59.044,500218405900
FCMA5B60L0D*+WALLCON · cold climate-20.012.59.044,500218405899
FCMA5B60L0D*+WALLCON · cold climate-20.012.59.044,500218405898
FCMA5B60L0D*+WALLCON · cold climate-20.012.59.044,500218405897
FCMA5B60L0D*+WALLCON · cold climate-20.012.59.044,500218405896
FCMA5B60L0D*+WALLCON · cold climate-20.012.59.044,500218628756
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.011.58.546,000218415023
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.011.58.546,000218415022
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.011.58.546,000218415021
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.011.58.546,000218415020
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.011.58.546,000218415019
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.011.58.546,000218415018
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.011.58.546,000218415017
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.011.58.546,000218415016
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.011.58.546,500218415015
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.011.58.546,500218415014
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.011.58.546,500218415013
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.011.58.546,500218415012
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.011.58.546,500218415011
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.011.58.546,500218415010
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.011.58.546,500218415009
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.011.58.546,500218415008
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.011.58.546,500218415007
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.011.58.546,500218415006
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.011.58.546,500218415005
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.011.58.546,500218415004
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.011.58.546,500218415003
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.011.58.546,500218415002
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.011.58.546,500218415001
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.011.58.546,500218415000
EA*5X61M24A*+WALLCON · cold climate*80CTL1352422B*19.011.58.546,000218629883
EA*5X61M24A*+WALLCON · cold climate*80CTL1102120B*19.011.58.546,500218629882
EA*5X61M24A*+WALLCON · cold climate*80CTL0902120B*19.011.58.546,500218629881
EA*5X61M24A*+WALLCON · cold climate*96CTN1202422B*18.511.58.546,500218415079
EA*5X61M24A*+WALLCON · cold climate*96CTN1202422B*18.511.58.546,500218415078
EA*5X61M24A*+WALLCON · cold climate*96CTN1202422B*18.511.58.546,500218415077
EA*5X61M24A*+WALLCON · cold climate*96CTN1202422B*18.511.58.546,500218415076
EA*5X61M24A*+WALLCON · cold climate*96CTN1202422B*18.511.58.546,500218415075
EA*5X61M24A*+WALLCON · cold climate*96CTN1202422B*18.511.58.546,500218415074
EA*5X61M24A*+WALLCON · cold climate*96CTN1202422B*18.511.58.546,500218415073
EA*5X61M24A*+WALLCON · cold climate*96CTN1202422B*18.511.58.546,500218415072
EA*5X61M24A*+WALLCON · cold climate*96CTN1002122B*18.511.58.546,500218415071
EA*5X61M24A*+WALLCON · cold climate*96CTN1002122B*18.511.58.546,500218415070
EA*5X61M24A*+WALLCON · cold climate*96CTN1002122B*18.511.58.546,500218415069
EA*5X61M24A*+WALLCON · cold climate*96CTN1002122B*18.511.58.546,500218415068
EA*5X61M24A*+WALLCON · cold climate*96CTN1002122B*18.511.58.546,500218415067
EA*5X61M24A*+WALLCON · cold climate*96CTN1002122B*18.511.58.546,500218415066
EA*5X61M24A*+WALLCON · cold climate*96CTN1002122B*18.511.58.546,500218415065
EA*5X61M24A*+WALLCON · cold climate*96CTN1002122B*18.511.58.546,500218415064
EA*5X61M24A*+WALLCON · cold climate*97CMN1202422B*18.511.08.546,500218415063
EA*5X61M24A*+WALLCON · cold climate*97CMN1202422B*18.511.08.546,500218415062
EA*5X61M24A*+WALLCON · cold climate*97CMN1202422B*18.511.08.546,500218415061
EA*5X61M24A*+WALLCON · cold climate*97CMN1202422B*18.511.08.546,500218415060
EA*5X61M24A*+WALLCON · cold climate*97CMN1202422B*18.511.08.546,500218415059
EA*5X61M24A*+WALLCON · cold climate*97CMN1202422B*18.511.08.546,500218415058
EA*5X61M24A*+WALLCON · cold climate*97CMN1202422B*18.511.08.546,500218415057
EA*5X61M24A*+WALLCON · cold climate*97CMN1202422B*18.511.08.546,500218415056
Yearly running cost in 10 large cities$1,336-$4,113

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Tempstar B5H3V60*K*AAA?
The Tempstar B5H3V60*K*AAA is rated at up to 20.0 SEER2 and 12.5 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 306 certified matchups SEER2 ranges from 17.5-20.0.
Is the Tempstar B5H3V60*K*AAA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 47,500 BTU/h at 5°F with a COP of 2.18, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
How much does the Tempstar B5H3V60*K*AAA cost to run per year?
At its rated efficiency it costs about $1,336-$4,113 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,722 in Phoenix and $3,494 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Tempstar B5H3V60*K*AAA?
ENERGY STAR lists 306 certified combinations for this outdoor unit. The highest-rated ones use FCMA5B60L0D*+WALLCON, EA*5X61M24A*+WALLCON.
What refrigerant does the Tempstar B5H3V60*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,747/yrYou save $1,231/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Tempstar B5H3V60*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,747
Current system, per year
$2,979
You save per year
$1,231
Payback
17.1 years
Net after 10 years
-$8,686

Cooling $994Heating $753Electricity used: 10,921 kWhSaved vs. a minimum-efficiency heat pump: $547

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 5 ton models

See all 100 5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 16, 2026. How we use the data.