4-ton central heat pump · Crossover Heat Pump

Tempstar D5CUHAH48AAK+KSAIC0701230

Below average cooling and heating efficiency for a 4-ton central heat pump, and certified for cold climates.

Ranks #278 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,575 a year to run in a mixed climate like Atlanta.

SEER2
15.5 Cooling efficiency over a season
Below average · beats 15%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
8.5 Cooling efficiency on a 95°F day
Below average · beats 1%
Heat at 5°F
46,000 BTU/h92% of its 47°F output
Below average · beats 2%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 46,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 16 certified pairings.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandTempstar
Also sold asKeeprite, Day & Night, Comfortmaker, Arcoaire, Airquest, Heil, Smart Comfort
Outdoor unit modelD5CUHAH48AAK+KSAIC0701230
SeriesCrossover Heat Pump
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJune 27, 2024
Last certifiedJuly 17, 2026
Cooling
SEER2Seasonal efficiency, higher is better15.5 (range 15.5)
EER2Efficiency at 95°F outdoors8.5-9.0
Cooling capacity46,500-47,500 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-8.5
Capacity at 47°F48,500-50,000 BTU/h
Capacity at 17°F34,200-35,400 BTU/h
Capacity at 5°F44,000-46,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75-1.76
ENERGY STAR cold climateYes
Heating output as it gets colder92% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EA*5X61M24A at the standard test temperatures, in BTU/h:

Certified matchups16 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EA*5X61M24A · cold climate*80MSU0802120A*15.58.58.546,000218478658
EA*5X61M24A · cold climate*80MSU0802120A*15.58.58.546,000218478656
EA*5X61M24A · cold climate*80MSU0802120A*15.58.58.546,000218478655
EA*5X61M24A · cold climate*80MSU0802120A*15.58.58.546,000218478653
EA*5X61M24A · cold climate*80MSU0802120A*15.58.58.546,000218478651
EA*5X61M24A · cold climate*80MSU0802120A*15.58.58.546,000218478649
EA*5X61M24A · cold climate*80MSU0802120A*15.58.58.546,000218478647
EA*5X61M24A · cold climate*80MSU0802120A*15.58.58.546,000218680269
FTMA5B60L0D · cold climate-15.59.08.144,000218485660
FTMA5B60L0D · cold climate-15.59.08.144,000218485658
FTMA5B60L0D · cold climate-15.59.08.144,000218485656
FTMA5B60L0D · cold climate-15.59.08.144,000218485654
FTMA5B60L0D · cold climate-15.59.08.144,000218485652
FTMA5B60L0D · cold climate-15.59.08.144,000218485650
FTMA5B60L0D · cold climate-15.59.08.144,000218485648
FTMA5B60L0D · cold climate-15.59.08.144,000218680928
Yearly running cost in 10 large cities$1,438-$3,742

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Tempstar D5CUHAH48AAK+KSAIC0701230?
The Tempstar D5CUHAH48AAK+KSAIC0701230 is rated at up to 15.5 SEER2 and 8.5 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the Tempstar D5CUHAH48AAK+KSAIC0701230 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 46,000 BTU/h at 5°F with a COP of 1.76, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
How much does the Tempstar D5CUHAH48AAK+KSAIC0701230 cost to run per year?
At its rated efficiency it costs about $1,438-$3,742 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,759 in Phoenix and $3,115 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Tempstar D5CUHAH48AAK+KSAIC0701230?
ENERGY STAR lists 16 certified combinations for this outdoor unit. The highest-rated ones use EA*5X61M24A, FTMA5B60L0D.
What refrigerant does the Tempstar D5CUHAH48AAK+KSAIC0701230 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,738/yrYou save $753/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Tempstar D5CUHAH48AAK+KSAIC0701230
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,738
Current system, per year
$2,490
You save per year
$753
Payback
23.9 years
Net after 10 years
-$10,474

Cooling $1,079Heating $659Electricity used: 10,860 kWhSaved vs. a minimum-efficiency heat pump: $178

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 17, 2026. How we use the data.