HVAC Rated

1.5-ton central heat pump · MAINLINE 16 SEER2 HP

Tempstar T5H6S18*K*AAA

Below average cooling and heating efficiency for a 1.5-ton central heat pump, but not rated for cold climates.

Ranks #146 of 170 1.5 ton central heat pumps for cooling efficiency, and costs about $591 a year to run in a mixed climate like Atlanta.

SEER2
15.5 Cooling efficiency over a season
Below average · beats 15%
HSPF2
8.0 Heating efficiency over a season
Below average · beats 12%
EER2
12.5 Cooling efficiency on a 95°F day
Very good · beats 80%
Heat at 5°F
8,500 BTU/h46% of its 47°F output
Average · beats 58%

A good fit if…

  • You want a choice of indoor units - 46 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications1.5 ton, R-454B
General
BrandTempstar
Also sold asKenmore
Outdoor unit modelT5H6S18*K*AAA
SeriesMAINLINE 16 SEER2 HP
TypeCentral heat pump
Nominal size1.5 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJuly 1, 2022
Last certifiedJuly 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better15.5 (range 15.2-15.5)
EER2Efficiency at 95°F outdoors11.7-12.5
Cooling capacity17,400-18,900 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.0
Capacity at 47°F16,400-18,100 BTU/h
Capacity at 17°F10,500-10,900 BTU/h
Capacity at 5°F8,200-8,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.94-2.10
ENERGY STAR cold climateNo
Heating output as it gets colder46% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FMA5X24**AL at the standard test temperatures, in BTU/h:

Certified matchups46 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FMA5X24**AL-15.512.58.08,200214423970
EVM5X32M17A*80MS(N,L)0701712A*15.512.07.88,200214156830
EVM5X32M17A*80MS(N,L)0701716A*15.512.07.88,200214156838
FM(C,U)5Z18**AL-15.212.08.08,500215828878
FM(C,U)5Z24**AL-15.212.08.08,500215828886
EA*5X25M17A*80VSL0451412B*15.212.07.88,400214150718
EA*5X25M17A*80VSL0701716B*15.212.07.88,400214150734
EA*5X25M17A*80ESU0401712A*15.212.07.88,400214150750
EA*5X25M17A*80MSU0401712A*15.212.07.88,400214150766
EA*5X25M17A*80MSU0601716A*15.212.07.88,400214150774
EA*5X25M17A*80CTL0701412B*15.212.07.88,400214150791
EA*5X25M17A*80CTL0701716B*15.212.07.88,500214150799
EA*5X25M17A*80CTL0901716B*15.212.07.88,500214150807
EA*5X25M17A*80VTL0451412B*15.212.07.88,400214150823
EA*5X25M17A*80VTL0701716B*15.211.77.88,500214150831
EA*5X25M17A*92MSN0601714A*15.212.07.88,400214150903
EA*5X25M17A*92MSN0801716A*15.212.07.88,400214150911
EA*5X25M17A*96MSN0801716A*15.211.77.88,500214150927
EA*5X25M17A*95MSU0601716A*15.212.07.88,500214150959
EA*5X25M17A*96CTN0801714B*15.212.07.88,400214150975
EA*5X25M17A*96VTN0601716B*15.211.77.88,400214150999
EA*5X19M17A*80MSU0401712A*15.212.07.88,400214150389
EA*5X19M17A*80MSU0601716A*15.212.07.88,400214150397
EA*5X19M17A*80MS(N,L)0451412A*15.212.07.88,400214150301
EA*5X19M17A*80VSL0451412B*15.211.77.88,400214150349
EA*5X19M17A*80VSL0701716B*15.211.77.88,400214150365
EA*5X19M17A*80ESU0401712A*15.212.07.88,300214150373
EA*5X19M17A*80MS(N,L)0701412A*15.212.07.88,400214150309
EA*5X19M17A*80MS(N,L)0701712A*15.212.07.88,300214150317
EA*5X19M17A*80MS(N,L)0701716A*15.212.07.88,400214150325
EA*5X19M17A*80MS(N,L)0901714A*15.212.07.88,400214150333
EA*5X19M17A*80CTL0701412B*15.212.07.88,400214150421
EA*5X19M17A*80CTL0901716B*15.212.07.88,400214150437
EA*5X19M17A*92MSN0601714A*15.212.07.88,400214150510
EA*5X19M17A*92MSN0801716A*15.212.07.88,400214150518
EA*5X19M17A*95MSU0601716A*15.212.07.88,400214150574
EA*5X19M17A*96CTN0801714B*15.212.07.88,400214150590
EA*5X25M17A*80MS(N,L)0451412A*15.212.07.88,400214150662
EA*5X25M17A*80MS(N,L)0701412A*15.212.07.88,400214150678
EA*5X25M17A*80MS(N,L)0701712A*15.212.07.88,400214150686
EA*5X25M17A*80MS(N,L)0701716A*15.212.07.88,500214150694
EA*5X25M17A*80MS(N,L)0901714A*15.212.07.88,400214150702
FHMA5*30L*B-15.212.07.88,400214165182
FMA5X18**AL-15.212.07.88,200214423962
FM(C,U)5Z30**AL-15.212.07.88,200215828894
F5MA5*30L*B-15.212.07.88,400216463730
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Tempstar T5H6S18*K*AAA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$548-$1,398

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Tempstar T5H6S18*K*AAA?
The Tempstar T5H6S18*K*AAA is rated at up to 15.5 SEER2 and 12.5 EER2 for cooling and up to 8.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 46 certified matchups SEER2 ranges from 15.2-15.5.
Is the Tempstar T5H6S18*K*AAA good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 1.5-ton model.
How much does the Tempstar T5H6S18*K*AAA cost to run per year?
At its rated efficiency it costs about $548-$1,398 a year in electricity in large U.S. cities, depending on climate and local rates - for example $666 in Phoenix and $1,161 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Tempstar T5H6S18*K*AAA the same as the Kenmore (C,H,T)5H6S18*K*AAA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Tempstar T5H6S18*K*AAA?
ENERGY STAR lists 46 certified combinations for this outdoor unit. The highest-rated ones use FMA5X24**AL, EVM5X32M17A, FM(C,U)5Z18**AL.
What refrigerant does the Tempstar T5H6S18*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $656/yrYou save $267/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Tempstar T5H6S18*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$656
Current system, per year
$923
You save per year
$267
Payback
26.2 years
Net after 10 years
-$4,326

Cooling $411Heating $245Electricity used: 4,100 kWhSaved vs. a minimum-efficiency heat pump: $51

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 1.5 ton models

See all 170 1.5 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 16, 2026. How we use the data.