4-ton central heat pump · E Series
TOSOT TUD60-48W2/NHE-D(U)
Very good cooling and heating efficiency for a 4-ton central heat pump, and certified for cold climates.
Ranks #50 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,431 a year to run in a mixed climate like Atlanta.
- SEER2
- 19.0 Cooling efficiency over a seasonVery good · beats 85%
- HSPF2
- 10.0 Heating efficiency over a seasonVery good · beats 84%
- EER2
- 11.7 Cooling efficiency on a 95°F dayAverage · beats 43%
- Heat at 5°F
- 54,000 BTU/h100% of its 47°F outputAverage · beats 58%
A good fit if…
- You want low cooling bills - its SEER2 beats 85% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 54,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | TOSOT |
| Also sold as | GREE, BOREAL, The Heat Pump |
| Outdoor unit model | TUD60-48W2/NHE-D(U) |
| Series | E Series |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-32 |
| Connected (smart) capable | No |
| On the market since | March 17, 2026 |
| Last certified | August 20, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 19.0 (range 16.0-19.0) |
| EER2Efficiency at 95°F outdoors | 9.8-11.7 |
| Cooling capacity | 47,000-53,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.0-10.0 |
| Capacity at 47°F | 48,000-54,000 BTU/h |
| Capacity at 17°F | 35,200-45,000 BTU/h |
| Capacity at 5°F | 48,000-54,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-2.10 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TUD48AH2/NHG-D(U) at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| TUD48AH2/NHG-D(U) · cold climate | 19.0 | 11.7 | 10.0 | 48,000 | 218330462 |
| TUD60AH2/NHG-D(U) · cold climate | 18.2 | 11.2 | 10.0 | 54,000 | 218330463 |
| TCAC48H/NHA · cold climate | 16.0 | 11.0 | 9.0 | 48,000 | 218330461 |
| TCAC60H/NHA · cold climate | 16.0 | 9.8 | 9.0 | 54,000 | 218330460 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the TOSOT TUD60-48W2/NHE-D(U): the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- GREE GFU60HP230V1R32AO
- BOREAL ARX60HPJ1R32OA
- The Heat Pump THP-GUD60W2/NHE-D(U)
Yearly running cost in 10 large cities
- Phoenix, AZ$1,582/yr
- Miami, FL$1,286/yr
- Houston, TX$1,418/yr
- Atlanta, GA$1,431/yr
- Los Angeles, CA$1,392/yr
- New York, NY$3,416/yr
- Chicago, IL$2,773/yr
- Denver, CO$2,305/yr
- Seattle, WA$1,416/yr
- Minneapolis, MN$2,852/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the TOSOT TUD60-48W2/NHE-D(U)?
- The TOSOT TUD60-48W2/NHE-D(U) is rated at up to 19.0 SEER2 and 11.7 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4 certified matchups SEER2 ranges from 16.0-19.0.
- Is the TOSOT TUD60-48W2/NHE-D(U) good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 54,000 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
- How much does the TOSOT TUD60-48W2/NHE-D(U) cost to run per year?
- At its rated efficiency it costs about $1,286-$3,416 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,582 in Phoenix and $2,852 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the TOSOT TUD60-48W2/NHE-D(U) the same as the GREE GFU60HP230V1R32AO?
- Yes, as far as the certified ratings go. ENERGY STAR lists 4 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- Which indoor units work with the TOSOT TUD60-48W2/NHE-D(U)?
- ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use TUD48AH2/NHG-D(U), TUD60AH2/NHG-D(U), TCAC48H/NHA.
- What refrigerant does the TOSOT TUD60-48W2/NHE-D(U) use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- York YDC60E2D11 · cold climate19.0 SEER2 · 10.0 HSPF2
- Bosch BOHA-60RTB-M18S · cold climate19.0 SEER2 · 9.8 HSPF2
- Sure SP19AY48AJVC19.0 SEER2 · 10.0 HSPF2
- Midea MDV-V60WMN10T(A) · cold climate19.0 SEER2 · 9.8 HSPF2
- Ruud UP19AY48AJVC19.0 SEER2 · 10.0 HSPF2
- LG KUSXA482A · cold climate19.0 SEER2 · 9.6 HSPF2
- Rheem RP19AY48AJVC19.0 SEER2 · 10.0 HSPF2
- GREE FXU60HP230V1R45AO · cold climate19.0 SEER2 · 9.5 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 20, 2026. How we use the data.