2-ton central heat pump · XV17

Trane 4TWV7X24A1

Average cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #213 of 331 2 ton central heat pumps for cooling efficiency, and costs about $690 a year to run in a mixed climate like Atlanta.

SEER2
17.1 Cooling efficiency over a season
Average · beats 53%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
13,200 BTU/h71% of its 47°F output
Below average · beats 20%

A good fit if…

  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 71 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications2 ton, R-410A
General
BrandTrane
Also sold asAmerican Standard
Outdoor unit model4TWV7X24A1
SeriesXV17
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceApril 25, 2024
Last certifiedJuly 9, 2025
Cooling
SEER2Seasonal efficiency, higher is better17.1 (range 17.0-17.1)
EER2Efficiency at 95°F outdoors11.7-12.0
Cooling capacity22,200-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.5
Capacity at 47°F18,200-22,400 BTU/h
Capacity at 17°F16,300-17,800 BTU/h
Capacity at 5°F12,400-13,200 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.60-1.90
ENERGY STAR cold climateNo
Heating output as it gets colder71% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with TAMXB0B30V31 at the standard test temperatures, in BTU/h:

Certified matchups71 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 71 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
TAMXB0B30V31-17.112.08.512,900212391373
4TXCB004DS3S9V2B060U3VSA+LRP17.112.08.512,900213826417
4TXCB004DS3S9V2B060U3VSB+LRP17.112.08.512,900213826419
4TXCB004DS3S9V2B060U4PSB+LRP17.112.08.512,900213826421
4TXCB004DS3S9V2B060U4PSC+LRP17.112.08.512,900213826423
4PX*BU36BS3*UHMB080CCV3+LRP17.112.08.512,800213826323
4PX*BU36BS3*UHMB060ACV3+LRP17.112.08.512,700213826327
4PX*BU36BS3S9V2B040U3VSB+LRP17.112.08.512,600213826329
4PX*BU36BS3S9V2B040U3VSA+LRP17.112.08.512,600213826331
4PX*BU36BS3*UHMB060CCV3+LRP17.112.08.512,700213826325
4PX*BU36BS3S9V2B040U3PSB+LRP17.112.08.512,600213826333
4PX*BU36BS3S9V2B060U4PSC+LRP17.112.08.512,800213826339
4PX*BU36BS3S9V2B060U3VSA+LRP17.112.08.512,800213826341
4PX*BU36BS3S9V2B040U3PSC+LRP17.112.08.512,600213826343
4TXCB004DS3*UHMB060ACV3+LRP17.112.08.512,800213826395
4TXCB004DS3*UHMB080ACV3+LRP17.112.08.512,800213826399
4TXCB004DS3*UHMB060CCV3+LRP17.112.08.512,800213826397
4TXCB004DS3*UHMB080CCV3+LRP17.112.08.512,800213826401
4TXCB004DS3S9V2B040U3PSB+LRP17.112.08.512,700213826409
4TXCB004DS3S9V2B040U3PSC+LRP17.112.08.512,700213826411
4TXCB004DS3S9V2B040U3VSA+LRP17.112.08.512,700213826413
4TXCB004DS3S9V2B040U3VSB+LRP17.112.08.512,700213826415
TEM8A0B24V21+TDR+LRP-17.112.08.513,200214671709
TEM8A0B30V31+TDR+LRP-17.112.08.513,100214671712
4TXCB004DS3L8V1A040U3VSB+LRP17.112.08.212,600213826403
4TXCB004DS3L8V1A060U3VSB+LRP17.112.08.212,600213826405
4PX*BU30BS3*UHMB060CCV3+LRP17.112.08.213,000213826278
4PX*BU30BS3S9V2B060U4PSC+LRP17.112.08.213,200213826289
4PX*BU30BS3S9V2B060U3VSB+LRP17.112.08.213,200213826293
4PX*BU30BS3S9V2B060U4PSB+LRP17.112.08.213,200213826291
4PX*BU30BS3S9V2B060U3VSA+LRP17.112.08.213,200213826295
4PX*BU30BS3S9V2B040U3VSB+LRP17.112.08.212,900213826297
4PX*BU30BS3S9V2B040U3VSA+LRP17.112.08.212,900213826299
4PX*BU30BS3S9V2B040U3PSC+LRP17.112.08.212,900213826301
4PX*BU30BS3S9V2B040U3PSB+LRP17.112.08.212,900213826303
4TXCB003DS3S9V2B060U3VSB+LRP17.112.08.213,200213826347
4TXCB003DS3S9V2B060U4PSC+LRP17.112.08.213,200213826351
4TXCB003DS3S9V2B060U4PSB+LRP17.112.08.213,200213826349
4TXCB003DS3*UHMB060ACV3+LRP17.112.08.213,000213826357
4TXCB003DS3*UHMB080ACV3+LRP17.112.08.213,100213826361
4TXCB003DS3*UHMB060CCV3+LRP17.112.08.213,000213826359
4TXCB003DS3*UHMB080CCV3+LRP17.112.08.213,100213826363
4PX*BU30BS3*UHMB060ACV3+LRP17.112.08.213,000213826305
4PX*BU30BS3*UHMB080ACV3+LRP17.112.08.213,100213826307
4PX*BU30BS3*UHMB080CCV3+LRP17.112.08.213,100213826309
4PX*BU36BS3L8V1A060U3VSB+LRP17.112.08.212,500213826319
4PX*BU36BS3L8V1A040U3VSB+LRP17.112.08.212,500213826321
4TXCB003DS3S9V2B060U3VSA+LRP17.112.08.213,200213826345
4TXCB004DS3S9V2B060D3PSC+LRP17.111.78.212,600213826387
4TXCB004DS3S9V2B060D3VSB+LRP17.111.78.212,600213826389
4TXCB003DS3S9V2B040U3PSB+LRP17.112.08.212,900213826371
4TXCB003DS3S9V2B040U3PSC+LRP17.112.08.212,900213826373
4TXCB003DS3S9V2B040U3VSA+LRP17.112.08.212,900213826375
4TXCB003DS3S9V2B040U3VSB+LRP17.112.08.212,900213826377
4TXCB004DS3*DHMB080CCV3+LRP17.111.78.212,700213826383
4TXCB004DS3*DHMB080ACV3+LRP17.111.78.212,700213826381
4TXCB004DS3S9V2B060D3PSB+LRP17.111.78.212,600213826385
4PX*BU36BS3S8V2A040M3PDA17.112.08.112,400212391309
4PX*BU36BS3S8V2A040M3PCA17.112.08.112,400212391310
4TXCB003DS3L8V1A060U3VSB+LRP17.112.08.012,800213826367
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Trane 4TWV7X24A1: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$652-$1,621

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Trane 4TWV7X24A1?
The Trane 4TWV7X24A1 is rated at up to 17.1 SEER2 and 12.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 71 certified matchups SEER2 ranges from 17.0-17.1.
Is the Trane 4TWV7X24A1 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the Trane 4TWV7X24A1 cost to run per year?
At its rated efficiency it costs about $652-$1,621 a year in electricity in large U.S. cities, depending on climate and local rates - for example $787 in Phoenix and $1,341 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Trane 4TWV7X24A1 the same as the American Standard 4A6V7X24A1?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Trane 4TWV7X24A1?
ENERGY STAR lists 71 certified combinations for this outdoor unit. The highest-rated ones use TAMXB0B30V31, 4TXCB004DS3, 4PX*BU36BS3.
What refrigerant does the Trane 4TWV7X24A1 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $772/yrYou save $416/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Trane 4TWV7X24A1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$772
Current system, per year
$1,188
You save per year
$416
Payback
21.6 years
Net after 10 years
-$4,840

Cooling $490Heating $282Electricity used: 4,824 kWhSaved vs. a minimum-efficiency heat pump: $134

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 9, 2025. How we use the data.