HVAC Rated

3-ton central heat pump · TOP-DISCHARGE

UTL UCHA-36HDCTRN2

Average cooling efficiency and very good heating efficiency for a 3-ton central heat pump, and certified for cold climates.

Ranks #101 of 302 3 ton central heat pumps for cooling efficiency, and costs about $939 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
10.0 Heating efficiency over a season
Very good · beats 84%
EER2
11.0 Cooling efficiency on a 95°F day
Below average · beats 23%
Heat at 5°F
25,600 BTU/h75% of its 47°F output
Very good · beats 88%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 25,600 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3 ton, R-32
General
BrandUTL
Also sold asMDX
Outdoor unit modelUCHA-36HDCTRN2
SeriesTOP-DISCHARGE
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceJune 5, 2026
Last certifiedJune 29, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 18.0)
EER2Efficiency at 95°F outdoors11.0
Cooling capacity34,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better10.0
Capacity at 47°F34,200 BTU/h
Capacity at 17°F31,400 BTU/h
Capacity at 5°F25,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.30
ENERGY STAR cold climateYes
Heating output as it gets colder75% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with UCHA-36HDCALN2 at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
UCHA-36HDCALN2 · cold climate18.011.010.025,600218472798
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the UTL UCHA-36HDCTRN2: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

  • MDX MCHA-36HDCTO2
Yearly running cost in 10 large cities$890-$2,204

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the UTL UCHA-36HDCTRN2?
The UTL UCHA-36HDCTRN2 is rated at up to 18.0 SEER2 and 11.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the UTL UCHA-36HDCTRN2 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 25,600 BTU/h at 5°F with a COP of 2.30, so it is still 2.3 times as efficient as electric resistance heat at that temperature.
How much does the UTL UCHA-36HDCTRN2 cost to run per year?
At its rated efficiency it costs about $890-$2,204 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,073 in Phoenix and $1,822 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the UTL UCHA-36HDCTRN2 the same as the MDX MCHA-36HDCTO2?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the UTL UCHA-36HDCTRN2?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses UCHA-36HDCALN2.
What refrigerant does the UTL UCHA-36HDCTRN2 use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,052/yrYou save $712/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump UTL UCHA-36HDCTRN2
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,052
Current system, per year
$1,763
You save per year
$712
Payback
18.3 years
Net after 10 years
-$5,884

Cooling $669Heating $383Electricity used: 6,574 kWhSaved vs. a minimum-efficiency heat pump: $301

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.