HVAC Rated

4-ton central heat pump · AHU

UTL UCHA-60HDC(O)

Below average cooling efficiency and average heating efficiency for a 4-ton central heat pump, and certified for cold climates.

Ranks #225 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,656 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
9.2 Cooling efficiency on a 95°F day
Below average · beats 4%
Heat at 5°F
38,500 BTU/h71% of its 47°F output
Very good · beats 76%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 38,500 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Cooling cost matters most - its SEER2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications4 ton, R-454B
General
BrandUTL
Also sold asVillaTherm
Outdoor unit modelUCHA-60HDC(O)
SeriesAHU
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceFebruary 13, 2025
Last certifiedMarch 20, 2025
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 16.0)
EER2Efficiency at 95°F outdoors9.2
Cooling capacity54,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better9.0
Capacity at 47°F54,000 BTU/h
Capacity at 17°F35,000 BTU/h
Capacity at 5°F38,500 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.20
ENERGY STAR cold climateYes
Heating output as it gets colder71% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with UCHA-60HDC(I) at the standard test temperatures, in BTU/h:

Certified matchups1 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
UCHA-60HDC(I) · cold climate16.09.29.038,500214771550
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the UTL UCHA-60HDC(O): the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$1,580-$3,876

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the UTL UCHA-60HDC(O)?
The UTL UCHA-60HDC(O) is rated at up to 16.0 SEER2 and 9.2 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
Is the UTL UCHA-60HDC(O) good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 38,500 BTU/h at 5°F with a COP of 2.20, so it is still 2.2 times as efficient as electric resistance heat at that temperature.
How much does the UTL UCHA-60HDC(O) cost to run per year?
At its rated efficiency it costs about $1,580-$3,876 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,900 in Phoenix and $3,201 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the UTL UCHA-60HDC(O) the same as the VillaTherm VHP-UCHA-60HDCT?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the UTL UCHA-60HDC(O)?
ENERGY STAR lists 1 certified combination for this outdoor unit. The highest-rated one uses UCHA-60HDC(I).
What refrigerant does the UTL UCHA-60HDC(O) use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,860/yrYou save $924/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump UTL UCHA-60HDC(O)
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,860
Current system, per year
$2,784
You save per year
$924
Payback
22.2 years
Net after 10 years
-$11,256

Cooling $1,188Heating $672Electricity used: 11,625 kWhSaved vs. a minimum-efficiency heat pump: $276

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of March 20, 2025. How we use the data.