2-ton central heat pump · LX SERIES

York HH824E2S12

Average cooling efficiency and below average heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #182 of 331 2 ton central heat pumps for cooling efficiency, and costs about $703 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
18,700 BTU/h75% of its 47°F output
Excellent · beats 97%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 18,700 BTU/h at 5°F.
  • You want a choice of indoor units - 1,411 certified pairings.

Think twice if…

  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandYork
Also sold asColeman, Luxaire, Fraser-Johnston, CHAMPION HEATING AND COOLING, Kenmore
Outdoor unit modelHH824E2S12
SeriesLX SERIES
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJune 4, 2026
Last certifiedSeptember 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 16.0-18.0)
EER2Efficiency at 95°F outdoors11.0-12.0
Cooling capacity22,400-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-8.5
Capacity at 47°F22,000-24,000 BTU/h
Capacity at 17°F20,600-22,800 BTU/h
Capacity at 5°F17,200-18,700 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.22-2.46
ENERGY STAR cold climateYes
Heating output as it gets colder75% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with JHC24B5AC2SS1 at the standard test temperatures, in BTU/h:

Certified matchups1,411 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 1,411 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
JHC24B5AC2SS1 · cold climate-18.012.08.518,000218598220
JHC24B5AC2SS1 · cold climate-18.012.08.518,000218598237
JHC24B5AC2SS1 · cold climate-18.012.08.518,000218598234
JHC24B5AC2SS1 · cold climate-18.012.08.518,000218598232
JHC24B5AC2SS1 · cold climate-18.012.08.518,000218598230
JHC24B5AC2SS1 · cold climate-18.012.08.518,000218598224
JHE30B5AD2SS2 · cold climate-17.512.08.517,800218641736
JHC36B5AD2SS1 · cold climate-17.512.08.518,000218641728
CTM36B5ADS2 · cold climateY82E080B12LMPS117.512.08.518,200218641722
CTU36B5XDS2+TXV · cold climateY82V080B12SMPC117.512.08.517,800218641719
CTF36B5ADS2 · cold climateY82V080B12SMPC117.512.08.517,800218641718
CTM36B5ADS2 · cold climateY82V080B12SMPC117.512.08.517,800218641717
CTM36B5ADS2+JMC12B2SN1 · cold climate-17.512.08.518,100218641716
CTU36B5XDS2+JMC12B2SN1+TXV · cold climate-17.512.08.518,100218641711
CTF36B5ADS2+JMC12B2SN1 · cold climate-17.512.08.518,100218641710
CTU36B5XDS2+JME12B2SN2+TXV · cold climate-17.512.08.517,800218641709
CTF36B5ADS2+JME12B2SN2 · cold climate-17.512.08.517,800218641708
CTU36B5XDS2+TXV · cold climateY82E080B12LMPS117.512.08.518,200218641704
CTF36B5ADS2 · cold climateY82E080B12LMPS117.512.08.518,200218641703
CTM30B5ACS2 · cold climateY82V080B12SMPC117.511.78.518,200218641698
CTU30B5XCS2+TXV · cold climateY82E080B12LMPS117.511.78.518,100218641689
CTF30B5ACS2 · cold climateY82E080B12LMPS117.511.78.518,100218641688
CTU30B5XCS2+JMC12B2SN1+TXV · cold climate-17.512.08.517,900218641687
CTF30B5ACS2+JMC12B2SN1 · cold climate-17.512.08.517,900218641686
CTU30B5XCS2+JME12B2SN2+TXV · cold climate-17.512.08.517,500218641676
CTF30B5ACS2+JME12B2SN2 · cold climate-17.512.08.517,500218641675
CTU30B5XCS2+TXV · cold climateY82V080B12SMPC117.511.78.518,100218641669
CTF30B5ACS2 · cold climateY82V080B12SMPC117.511.78.518,100218641668
JHE24B5AC2SS2 · cold climate-17.512.08.517,900218641665
CTM30B5ACS2 · cold climateZ8VT080B12SMPC117.511.78.518,200218643402
CTM30B5ACS2 · cold climateZ8VT080B12SMPC117.511.78.518,200218643400
CTM30B5ACS2 · cold climateZ8VT080B12SMPC117.511.78.518,200218643399
CTM30B5ACS2 · cold climateZ8VT080B12SMPC117.511.78.518,200218643397
JHE30B5AD2SS2 · cold climate-17.512.08.517,800218642957
JHC36B5AD2SS1 · cold climate-17.512.08.518,000218642936
CTM36B5ADS2 · cold climateZ8ET080B12LMPS1*17.512.08.518,200218642919
CTU30B5XCS2+TXV · cold climateZ8VT080B12SMPC117.511.78.518,100218642763
CTF30B5ACS2 · cold climateZ8VT080B12SMPC117.511.78.518,100218642761
JHE24B5AC2SS2 · cold climate-17.512.08.517,900218642752
JHE30B5AD2SS2 · cold climate-17.512.08.517,800218643603
JHE30B5AD2SS2 · cold climate-17.512.08.517,800218643602
JHE30B5AD2SS2 · cold climate-17.512.08.517,800218643601
JHE30B5AD2SS2 · cold climate-17.512.08.517,800218643600
JHC36B5AD2SS1 · cold climate-17.512.08.518,000218643571
JHC36B5AD2SS1 · cold climate-17.512.08.518,000218643570
JHC36B5AD2SS1 · cold climate-17.512.08.518,000218643569
JHC36B5AD2SS1 · cold climate-17.512.08.518,000218643568
CTM36B5ADS2 · cold climateZ8ET080B12LMPS117.512.08.518,200218643547
CTM36B5ADS2 · cold climateZ8ET080B12LMPS117.512.08.518,200218643546
CTM36B5ADS2 · cold climateZ8ET080B12LMPS117.512.08.518,200218643545
CTM36B5ADS2 · cold climateZ8ET080B12LMPS117.512.08.518,200218643544
CTU36B5XDS2+TXV · cold climateZ8VT080B12SMPC117.512.08.517,800218643531
CTU36B5XDS2+TXV · cold climateZ8VT080B12SMPC117.512.08.517,800218643529
CTU36B5XDS2+TXV · cold climateZ8VT080B12SMPC117.512.08.517,800218643528
CTU36B5XDS2+TXV · cold climateZ8VT080B12SMPC117.512.08.517,800218643527
CTF36B5ADS2 · cold climateZ8VT080B12SMPC117.512.08.517,800218643525
CTF36B5ADS2 · cold climateZ8VT080B12SMPC117.512.08.517,800218643524
CTF36B5ADS2 · cold climateZ8VT080B12SMPC117.512.08.517,800218643522
CTF36B5ADS2 · cold climateZ8VT080B12SMPC117.512.08.517,800218643521
CTM36B5ADS2 · cold climateZ8VT080B12SMPC117.512.08.517,800218643520
Yearly running cost in 10 large cities$612-$1,695

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the York HH824E2S12?
The York HH824E2S12 is rated at up to 18.0 SEER2 and 12.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 1411 certified matchups SEER2 ranges from 16.0-18.0.
Is the York HH824E2S12 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 18,700 BTU/h at 5°F with a COP of 2.46, so it is still 2.5 times as efficient as electric resistance heat at that temperature.
How much does the York HH824E2S12 cost to run per year?
At its rated efficiency it costs about $612-$1,695 a year in electricity in large U.S. cities, depending on climate and local rates - for example $762 in Phoenix and $1,422 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the York HH824E2S12?
ENERGY STAR lists 1411 certified combinations for this outdoor unit. The highest-rated ones use JHC24B5AC2SS1, JHE30B5AD2SS2, JHC36B5AD2SS1.
What refrigerant does the York HH824E2S12 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $761/yrYou save $439/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump York HH824E2S12
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$761
Current system, per year
$1,200
You save per year
$439
Payback
20.5 years
Net after 10 years
-$4,606

Cooling $458Heating $303Electricity used: 4,754 kWhSaved vs. a minimum-efficiency heat pump: $159

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.