HVAC Rated

12,000 BTU mini-split heat pump · airCore700

York YPAS12BLFASDQ1

Average cooling efficiency and very good heating efficiency for a 12,000 BTU mini-split heat pump, and certified for cold climates.

Ranks #243 of 394 12,000 BTU mini-splits for cooling efficiency, and costs about $308 a year to run in a mixed climate like Atlanta.

SEER2
23.0 Cooling efficiency over a season
Average · beats 62%
HSPF2
11.3 Heating efficiency over a season
Very good · beats 81%
EER2
16.5 Cooling efficiency on a 95°F day
Excellent · beats 98%
Heat at 5°F
15,200 BTU/h99% of its 47°F output
Excellent · beats 93%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 15,200 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 81% of mini-splits.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications12,000 BTU, R-32
General
BrandYork
Also sold asHitachi
Outdoor unit modelYPAS12BLFASDQ1
SeriesairCore700
TypeMini-split heat pump
Nominal size12,000 BTU
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableNo
On the market sinceAugust 15, 2026
Last certifiedAugust 11, 2026
Cooling
SEER2Seasonal efficiency, higher is better23.0 (range 19.0-23.0)
EER2Efficiency at 95°F outdoors13.9-16.5
Cooling capacity12,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better10.0-11.3
Capacity at 47°F14,000 BTU/h
Capacity at 17°F12,000-12,600 BTU/h
Capacity at 5°F13,800-15,200 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.40
ENERGY STAR cold climateYes
Heating output as it gets colder99% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with YPCIMB12UFA1DQ at the standard test temperatures, in BTU/h:

Certified matchups2 indoor units

The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitSEER2EER2HSPF2Heat @5°FAHRI ref.
YPCIMB12UFA1DQ YORK · cold climate23.016.511.313,800218694252
YPPIMB12UFA1DQ YORK · cold climate19.013.910.015,200218694251
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the York YPAS12BLFASDQ1: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$247-$758

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the York YPAS12BLFASDQ1?
The York YPAS12BLFASDQ1 is rated at up to 23.0 SEER2 and 16.5 EER2 for cooling and up to 11.3 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 2 certified matchups SEER2 ranges from 19.0-23.0.
Is the York YPAS12BLFASDQ1 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 15,200 BTU/h at 5°F with a COP of 2.40, so it is still 2.4 times as efficient as electric resistance heat at that temperature.
How much does the York YPAS12BLFASDQ1 cost to run per year?
At its rated efficiency it costs about $247-$758 a year in electricity in large U.S. cities, depending on climate and local rates - for example $318 in Phoenix and $644 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the York YPAS12BLFASDQ1 the same as the Hitachi PAS-12BLFASDQ1?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the York YPAS12BLFASDQ1?
ENERGY STAR lists 2 certified combinations for this outdoor unit. The highest-rated ones use YORK YPCIMB12UFA1DQ, YORK YPPIMB12UFA1DQ.
What refrigerant does the York YPAS12BLFASDQ1 use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $322/yrYou save $329/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump York YPAS12BLFASDQ1
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$322
Current system, per year
$651
You save per year
$329
Payback
13.7 years
Net after 10 years
-$1,209

Cooling $184Heating $139Electricity used: 2,015 kWhSaved vs. a minimum-efficiency heat pump: $182

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 12,000 BTU models

See all 394 12,000 BTU mini-splits, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 11, 2026. How we use the data.