42,000 BTU mini-split heat pump · MJ Multi-Split
York YRAMG42N5HAA
Average cooling efficiency and below average heating efficiency for a 42,000 BTU mini-split heat pump, but not rated for cold climates.
Ranks #9 of 61 42,000 BTU mini-splits for cooling efficiency, and costs about $1,169 a year to run in a mixed climate like Atlanta.
- SEER2
- 23.0 Cooling efficiency over a seasonAverage · beats 62%
- HSPF2
- 9.2 Heating efficiency over a seasonBelow average · beats 16%
- EER2
- 12.5 Cooling efficiency on a 95°F dayAverage · beats 44%
- Heat at 5°F
- 29,400 BTU/h65% of its 47°F outputAverage · beats 48%
A good fit if…
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for mini-splits.
Details
Specifications
| General | |
|---|---|
| Brand | York |
| Also sold as | Hitachi |
| Outdoor unit model | YRAMG42N5HAA |
| Series | MJ Multi-Split |
| Type | Mini-split heat pump |
| Nominal size | 42,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-32 |
| Connected (smart) capable | No |
| On the market since | March 1, 2026 |
| Last certified | October 7, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 23.0 (range 23.0) |
| EER2Efficiency at 95°F outdoors | 12.5 |
| Cooling capacity | 42,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.2 |
| Capacity at 47°F | 45,000 BTU/h |
| Capacity at 17°F | 30,000 BTU/h |
| Capacity at 5°F | 29,400 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.00 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - YORK | 23.0 | 12.5 | 9.2 | 29,400 | 218014987 |
Same unit, other model numbers
Yearly running cost in 10 large cities
- Phoenix, AZ$1,155/yr
- Miami, FL$868/yr
- Houston, TX$1,039/yr
- Atlanta, GA$1,169/yr
- Los Angeles, CA$1,164/yr
- New York, NY$2,937/yr
- Chicago, IL$2,413/yr
- Denver, CO$2,028/yr
- Seattle, WA$1,264/yr
- Minneapolis, MN$2,520/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the York YRAMG42N5HAA?
- The York YRAMG42N5HAA is rated at up to 23.0 SEER2 and 12.5 EER2 for cooling and up to 9.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with.
- Is the York YRAMG42N5HAA good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 42,000 BTU model.
- How much does the York YRAMG42N5HAA cost to run per year?
- At its rated efficiency it costs about $868-$2,937 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,155 in Phoenix and $2,520 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the York YRAMG42N5HAA the same as the York YRAMG42N5HBA?
- Yes, as far as the certified ratings go. ENERGY STAR lists 4 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- What refrigerant does the York YRAMG42N5HAA use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 42,000 BTU models
- TOSHIBA CARRIER RAV-BP421AT2P-UL · cold climate22.6 SEER2 · 11.2 HSPF2
- TCL TMH42HDI2NAO0U25 · cold climate24.0 SEER2 · 10.0 HSPF2
- Hitachi PAS-48BUFASDQ1-LAC · cold climate22.5 SEER2 · 10.0 HSPF2
- TCL H42FMH22XQC · cold climate24.0 SEER2 · 10.0 HSPF2
- MDV M5OG-42HFN1-M-[X] · cold climate22.3 SEER2 · 10.5 HSPF2
- DELLA 048-TCQ-MODU-1D5 · cold climate24.0 SEER2 · 10.0 HSPF2
- Fujitsu AOUH42KUAH1 · cold climate22.0 SEER2 · 10.6 HSPF2
- AUX ASUM42HPMULO · cold climate24.0 SEER2 · 10.5 HSPF2
See all 61 42,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 7, 2026. How we use the data.