36,000 BTU mini-split heat pump · MH MULTI-SPLIT
York YRAMX36N4HAA
Average cooling efficiency and very good heating efficiency for a 36,000 BTU mini-split heat pump, and certified for cold climates.
Ranks #80 of 205 36,000 BTU mini-splits for cooling efficiency, and costs about $849 a year to run in a mixed climate like Atlanta.
- SEER2
- 22.0 Cooling efficiency over a seasonAverage · beats 48%
- HSPF2
- 11.0 Heating efficiency over a seasonVery good · beats 75%
- EER2
- 12.5 Cooling efficiency on a 95°F dayAverage · beats 44%
- Heat at 5°F
- 26,000 BTU/h72% of its 47°F outputBelow average · beats 9%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 26,000 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 75% of mini-splits.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | York |
| Also sold as | Hitachi |
| Outdoor unit model | YRAMX36N4HAA |
| Series | MH MULTI-SPLIT |
| Type | Mini-split heat pump |
| Nominal size | 36,000 BTU |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-32 |
| Connected (smart) capable | No |
| On the market since | March 1, 2026 |
| Last certified | September 30, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 22.0 (range 18.0-22.0) |
| EER2Efficiency at 95°F outdoors | 11.0-12.5 |
| Cooling capacity | 33,000-36,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 10.5-11.0 |
| Capacity at 47°F | 36,000 BTU/h |
| Capacity at 17°F | 26,000-26,400 BTU/h |
| Capacity at 5°F | 26,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.75-1.80 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its best matchup at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| - YORK · cold climate | 22.0 | 12.5 | 10.5 | 26,000 | 218029791 |
| - YORK · cold climate | 20.0 | 11.8 | 10.8 | 26,000 | 218029793 |
| - YORK · cold climate | 18.0 | 11.0 | 11.0 | 26,000 | 218029792 |
Same unit, other model numbers
These model numbers have exactly the same certified ratings and matchups as the York YRAMX36N4HAA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.
- Hitachi RAM-X36N4HAA
Yearly running cost in 10 large cities
- Phoenix, AZ$918/yr
- Miami, FL$736/yr
- Houston, TX$824/yr
- Atlanta, GA$849/yr
- Los Angeles, CA$829/yr
- New York, NY$2,048/yr
- Chicago, IL$1,666/yr
- Denver, CO$1,388/yr
- Seattle, WA$855/yr
- Minneapolis, MN$1,719/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the York YRAMX36N4HAA?
- The York YRAMX36N4HAA is rated at up to 22.0 SEER2 and 12.5 EER2 for cooling and up to 11.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3 certified matchups SEER2 ranges from 18.0-22.0.
- Is the York YRAMX36N4HAA good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 26,000 BTU/h at 5°F with a COP of 1.80, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
- How much does the York YRAMX36N4HAA cost to run per year?
- At its rated efficiency it costs about $736-$2,048 a year in electricity in large U.S. cities, depending on climate and local rates - for example $918 in Phoenix and $1,719 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Is the York YRAMX36N4HAA the same as the Hitachi RAM-X36N4HAA?
- Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
- What refrigerant does the York YRAMX36N4HAA use?
- It uses R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 36,000 BTU models
- LG KUMXA361A · cold climate22.0 SEER2 · 11.0 HSPF2
- Fujitsu AOUH36KUAH1 · cold climate22.0 SEER2 · 10.7 HSPF2
- Lennox VPD036S6M-5P · cold climate22.0 SEER2 · 11.0 HSPF2
- Lennox MMLD036S6S-1P · cold climate22.0 SEER2 · 10.6 HSPF2
- GE Appliances MWHQ036NC2AA · cold climate22.0 SEER2 · 13.5 HSPF2
- Samsung AC036DXSCCG · cold climate22.0 SEER2 · 10.6 HSPF2
- MOOVAIR DMA36HOM25230X3 · cold climate22.2 SEER2 · 10.3 HSPF2
- Panasonic CU-5Z36BBUC · cold climate22.0 SEER2 · 10.3 HSPF2
See all 205 36,000 BTU mini-splits, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.