3-ton central heat pump · Ultra Heat Unitary Condensing Unit
1HVAC SC-2436-HP
Average cooling and heating efficiency for a 3-ton central heat pump, and certified for cold climates.
Ranks #154 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,036 a year to run in a mixed climate like Atlanta.
- SEER2
- 17.0 Cooling efficiency over a seasonAverage · beats 49%
- HSPF2
- 9.0 Heating efficiency over a seasonAverage · beats 54%
- EER2
- 12.0 Cooling efficiency on a 95°F dayAverage · beats 64%
- Heat at 5°F
- 28,000 BTU/h92% of its 47°F outputBelow average · beats 5%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 28,000 BTU/h at 5°F.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | 1HVAC |
| Also sold as | ACIQ, DIYCOOL, Stealth Comfort |
| Outdoor unit model | SC-2436-HP |
| Series | Ultra Heat Unitary Condensing Unit |
| Type | Central heat pump |
| Nominal size | 3 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | January 1, 2023 |
| Last certified | June 29, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 17.0 (range 16.0-17.0) |
| EER2Efficiency at 95°F outdoors | 10.0-12.0 |
| Cooling capacity | 24,000-34,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.0 |
| Capacity at 47°F | 24,000-35,000 BTU/h |
| Capacity at 17°F | 20,000-29,000 BTU/h |
| Capacity at 5°F | 22,000-28,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with SC-24-AH at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| SC-24-AH · cold climate | 17.0 | 12.0 | 9.0 | 22,000 | 211717281 |
| SC-24-AH · cold climate | 17.0 | 12.0 | 9.0 | 22,000 | 211717285 |
| SC-24-AH · cold climate | 17.0 | 12.0 | 9.0 | 22,000 | 211717289 |
| SC-24-AH · cold climate | 17.0 | 12.0 | 9.0 | 22,000 | 211717293 |
| SC-36-AH · cold climate | 16.0 | 10.0 | 9.0 | 28,000 | 211717282 |
| SC-36-AH · cold climate | 16.0 | 10.0 | 9.0 | 28,000 | 211717286 |
| SC-36-AH · cold climate | 16.0 | 10.0 | 9.0 | 28,000 | 211717290 |
| SC-36-AH · cold climate | 16.0 | 10.0 | 9.0 | 28,000 | 211717294 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,152/yr
- Miami, FL$939/yr
- Houston, TX$1,032/yr
- Atlanta, GA$1,036/yr
- Los Angeles, CA$1,007/yr
- New York, NY$2,467/yr
- Chicago, IL$2,001/yr
- Denver, CO$1,662/yr
- Seattle, WA$1,020/yr
- Minneapolis, MN$2,057/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the 1HVAC SC-2436-HP?
- The 1HVAC SC-2436-HP is rated at up to 17.0 SEER2 and 12.0 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 8 certified matchups SEER2 ranges from 16.0-17.0.
- Is the 1HVAC SC-2436-HP good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 28,000 BTU/h at 5°F with a COP of 1.80, so it is still 1.8 times as efficient as electric resistance heat at that temperature.
- How much does the 1HVAC SC-2436-HP cost to run per year?
- At its rated efficiency it costs about $939-$2,467 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,152 in Phoenix and $2,057 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the 1HVAC SC-2436-HP?
- ENERGY STAR lists 8 certified combinations for this outdoor unit. The highest-rated ones use SC-24-AH, SC-36-AH.
- What refrigerant does the 1HVAC SC-2436-HP use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 3 ton models
- Trane 5HCL5036A1 · cold climate17.0 SEER2 · 9.4 HSPF2
- Airquest D5CUHAH36AAK+KSAIC0701230 · cold climate17.0 SEER2 · 9.0 HSPF2
- TCL H36TDHXPC · cold climate17.0 SEER2 · 9.5 HSPF2
- Airtemp GXH24-36MSK4DH · cold climate17.0 SEER2 · 9.0 HSPF2
- Sure SP17AY36AJVC · cold climate17.0 SEER2 · 9.5 HSPF2
- Carrier 37MUHAQ36AA3+KSAIC0701230 · cold climate17.0 SEER2 · 9.0 HSPF2
- Rheem RP17AY36AJVC · cold climate17.0 SEER2 · 9.5 HSPF2
- MRCOOL MDUO18024036 · cold climate17.0 SEER2 · 9.0 HSPF2
See all 302 3 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 29, 2026. How we use the data.