HVAC Rated

3-ton central heat pump · Crossover Heat Pump

Carrier 37MUHAQ36AA3+KSAIC0701230

Average cooling and heating efficiency for a 3-ton central heat pump, and certified for cold climates.

Ranks #157 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,110 a year to run in a mixed climate like Atlanta.

SEER2
17.0 Cooling efficiency over a season
Average · beats 49%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
10.0 Cooling efficiency on a 95°F day
Below average · beats 10%
Heat at 5°F
31,600 BTU/h79% of its 47°F output
Below average · beats 20%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 31,600 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 1,145 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandCarrier
Also sold asBryant, PAYNE HEATING AND COOLING, WeatherMaker
Outdoor unit model37MUHAQ36AA3+KSAIC0701230
SeriesCrossover Heat Pump
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJune 27, 2024
Last certifiedOctober 7, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.0 (range 15.2-17.0)
EER2Efficiency at 95°F outdoors9.4-10.5
Cooling capacity34,200-38,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-9.0
Capacity at 47°F37,400-40,000 BTU/h
Capacity at 17°F24,400-26,200 BTU/h
Capacity at 5°F29,800-31,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.75-1.90
ENERGY STAR cold climateYes
Heating output as it gets colder79% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FT5AN(B,X)C48L at the standard test temperatures, in BTU/h:

Certified matchups1,145 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 1,145 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
FT5AN(B,X)C48L · cold climate-17.010.08.529,800218474606
PF5TNXC48L · cold climate-17.010.08.529,800218480443
PF5TNXC48L · cold climate-17.010.08.529,800218480441
FG5ANXC48L · cold climate-17.010.08.529,800218479371
FG5ANXC48L · cold climate-17.010.08.529,800218479369
FT5AN(B,X)C48L · cold climate-17.010.08.529,800218479368
PF5TNXC48L · cold climate-17.010.08.529,800218815967
CAA**4821AM · cold climate58SU*B080M21**2016.910.08.530,000218474431
CAA**4821AM · cold climatePG80MSUA60080C**16.910.08.530,000218479833
CAA**4821AM · cold climate83*SB60080M21***16.910.08.530,000218479831
CAA**4821AM · cold climatePG80MSUA60080C**16.910.08.530,000218815858
FMA5X36**AL · cold climate-16.510.09.031,600218474651
FMA5X36**AL · cold climate-16.510.09.031,600218480476
FMA5X36**AL · cold climate-16.510.09.031,600218480474
FMA5X36**AL · cold climate-16.510.09.031,600218815975
FT5AN(B,X)C36L · cold climate-16.510.08.531,000218473013
CAA**4321AM · cold climate59TP7A100V21**2216.510.08.530,200218474485
CAA**4321AM · cold climate59TP6C100V21**2216.510.08.530,200218474480
CAA**4321AM · cold climate59SU5B100M21**2216.510.08.530,200218474474
CAA**4321AM · cold climate59SU5B080M21**2016.510.08.530,400218474472
CAA**4321AM · cold climate58TP*B110V21**2216.510.08.530,200218474464
CAA**4321AM · cold climate58TP*B090V21**2016.510.08.530,400218474463
CAA**4321AM · cold climate58SU*B100M21**2016.510.08.530,400218474460
CAA**4321AM · cold climate58SU*B080M21**2016.510.08.530,200218474459
CAA**4321AM · cold climate58SU*B060M17**1616.510.08.530,200218474458
CAA**4321AM · cold climate58SU*B040M17**1216.510.08.530,200218474457
CAA**4321AM · cold climate58SP*B110V21**2216.510.08.530,200218474456
CAA**4321AM · cold climate58SP*B090V21**2016.510.08.530,400218474455
CAA**4821AM · cold climate59TP7A080V21**2016.59.88.530,200218474447
CAA**4821AM · cold climate59TP6C080V21**2016.59.88.530,200218474444
CAA**4821AM · cold climate59SU5B100M21**2216.510.08.530,000218474441
CAA**4821AM · cold climate59SU5B100M21**2016.510.08.530,200218474440
CAA**4821AM · cold climate59SP6B080V21**2016.59.88.530,200218474437
CAA**4821AM · cold climate58TP*B110V21**2216.510.08.530,200218474434
CAA**4821AM · cold climate58SU*B060M17**1616.510.08.530,000218474430
CAA**4821AM · cold climate58SP*B110V21**2216.510.08.530,200218474429
CAA**3721AM · cold climate59TP7A100V21**2216.510.08.530,200218474558
CAA**3721AM · cold climate59TP6C100V21**2216.510.08.530,200218474553
CAA**3721AM · cold climate58SU*B080M21**2016.510.08.530,200218474532
CAA**3721AM · cold climate58SU*B060M17**1616.510.08.530,200218474531
CAA**3721AM · cold climate58SP*B110V21**2216.510.08.530,200218474529
CAA**4221AM · cold climate59SU5B100M21**2216.59.88.530,800218474511
CAA**4221AM · cold climate58SU*B080M21**2016.59.58.530,800218474496
CAA**4221AM · cold climate58SP*B110V21**2216.59.88.530,800218474493
FT5AN(B,X)C36L · cold climate-16.510.08.531,000218475378
PF5TNXC36L · cold climate-16.510.08.531,000218475377
CAA**3721AM · cold climate927TA66100V21***16.510.08.530,200218480284
CAA**3721AM · cold climate926TC66100V21***16.510.08.530,200218480266
CAA**3721AM · cold climatePG80MSUA60080C**16.510.08.530,200218480190
CAA**3721AM · cold climate83*SB60080M21***16.510.08.530,200218480188
CAA**3721AM · cold climatePG80MSUA48060B**16.510.08.530,200218480186
CAA**3721AM · cold climate83*SB48060M17***16.510.08.530,200218480185
CAA**3721AM · cold climate82*SB66110V21***16.510.08.530,200218480178
CAA**4221AM · cold climate935SB66100M21***16.59.88.530,800218480120
CAA**4221AM · cold climatePG80MSUA60080C**16.59.58.530,800218480074
CAA**4221AM · cold climate83*SB60080M21***16.59.58.530,800218480072
CAA**4221AM · cold climate82*SB66110V21***16.59.88.530,800218480062
CAA**4321AM · cold climate927TA66100V21***16.510.08.530,200218480046
CAA**4321AM · cold climate926TC66100V21***16.510.08.530,200218480028
CAA**4321AM · cold climate935SB66100M21***16.510.08.530,200218480000
Yearly running cost in 10 large cities$985-$2,660

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Carrier 37MUHAQ36AA3+KSAIC0701230?
The Carrier 37MUHAQ36AA3+KSAIC0701230 is rated at up to 17.0 SEER2 and 10.0 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 1145 certified matchups SEER2 ranges from 15.2-17.0.
Is the Carrier 37MUHAQ36AA3+KSAIC0701230 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 31,600 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
How much does the Carrier 37MUHAQ36AA3+KSAIC0701230 cost to run per year?
At its rated efficiency it costs about $985-$2,660 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,217 in Phoenix and $2,225 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Carrier 37MUHAQ36AA3+KSAIC0701230?
ENERGY STAR lists 1145 certified combinations for this outdoor unit. The highest-rated ones use FT5AN(B,X)C48L, PF5TNXC48L, FG5ANXC48L.
What refrigerant does the Carrier 37MUHAQ36AA3+KSAIC0701230 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,210/yrYou save $665/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Carrier 37MUHAQ36AA3+KSAIC0701230
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,210
Current system, per year
$1,875
You save per year
$665
Payback
20.3 years
Net after 10 years
-$6,851

Cooling $737Heating $473Electricity used: 7,563 kWhSaved vs. a minimum-efficiency heat pump: $234

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 7, 2026. How we use the data.