HVAC Rated

3-ton central heat pump · LX SERIES

York YH636E2S11

Average cooling efficiency and below average heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #169 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,073 a year to run in a mixed climate like Atlanta.

SEER2
17.0 Cooling efficiency over a season
Average · beats 49%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
19,800 BTU/h54% of its 47°F output
Excellent · beats 99%

A good fit if…

  • You want a choice of indoor units - 496 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandYork
Outdoor unit modelYH636E2S11
SeriesLX SERIES
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceApril 1, 2025
Last certifiedAugust 5, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.0 (range 15.2-17.0)
EER2Efficiency at 95°F outdoors11.0-12.0
Cooling capacity32,800-36,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.0-8.5
Capacity at 47°F34,000-36,200 BTU/h
Capacity at 17°F22,000-23,800 BTU/h
Capacity at 5°F17,600-19,800 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.50
ENERGY STAR cold climateNo
Heating output as it gets colder54% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CTF48C5CFS1+JMET12CS2N1 at the standard test temperatures, in BTU/h:

Certified matchups496 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 496 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CTF48C5CFS1+JMET12CS2N1-17.012.08.519,300217017113
CTU48C5XFS1+JMET12CS2N1+TXV-17.012.08.519,300217017115
CTF48C5CFS1+JMC16C2SN1-17.012.08.519,300217017117
CTU48C5XFS1+JMC16C2SN1+TXV-17.012.08.519,300217017119
CTF48C5CFS1Y82E080C16LMPS117.012.08.519,300217017121
CTU48C5XFS1+TXVY82E080C16LMPS117.012.08.519,300217017123
CTF48C5CFS1Y81E120C16SMPS117.012.08.519,100217017221
CTF48C5CFS1Y81E120C16LMPS117.012.08.519,100217017223
CTU48C5XFS1+TXVY81E120C16SMPS117.012.08.519,100217017225
CTU48C5XFS1+TXVY81E120C16LMPS117.012.08.519,100217017227
CTF48D5CFS1+JME18D2SN1-17.012.08.519,000217017229
CTF48C5CFS1Y82E100C16LMPS117.012.08.519,300217017231
CTU48C5XFS1+TXVY82E100C16LMPS117.012.08.519,300217017232
CTF48C5CFS1+JMC17C2SN1-17.012.08.519,100217017255
CTU48C5XFS1+JMC17C2SN1+TXV-17.012.08.519,100217017257
CTF48C5CFS1+JMVT16CC2N1-17.012.08.519,300217017259
CTU48C5XFS1+JMVT16CC2N1+TXV-17.012.08.519,300217017261
CTF48C5CFS1+JME12C2SN1-17.012.08.519,000217017290
CTU48C5XFS1+JME12C2SN1+TXV-17.012.08.519,000217017292
CTF48D5CFS1+JMC20D2SN1-17.012.08.519,100217017155
CTF48D5CFS1+JMVT20DC2N1-17.012.08.519,100217017157
CTF48C5CFS1Y81E080C20SMPS117.012.08.519,300217017159
CTF48C5CFS1Y81E080C20LMPS117.012.08.519,300217017161
CTU48C5XFS1+TXVY81E080C20SMPS117.012.08.519,300217017163
CTU48C5XFS1+TXVY81E080C20LMPS117.012.08.519,300217017165
CTU48C5XFS1+TXVY81E100C16SMPS117.012.08.519,500217017195
CTF48C5CFS1+JMVT17CC2N1-17.012.08.519,100217017187
CTU48C5XFS1+JMVT17CC2N1+TXV-17.012.08.519,100217017189
CTF48C5CFS1Y81E100C16SMPS117.012.08.519,500217017190
CTF48C5CFS1Y81E100C16LMPS117.012.08.519,500217017192
CTU48C5XFS1+TXVY81E100C16LMPS117.012.08.519,500217017196
CTF48D5CFS2+JMC20D2SN1-17.012.08.519,100218507888
CTF48D5CFS2+JMVT20DC2N1-17.012.08.519,100218507886
CTU48C5XFS2+TXVY81E100C16LMPS117.012.08.519,500218507814
CTU48C5XFS2+TXVY81E100C16SMPS117.012.08.519,500218507811
CTF48C5CFS2Y81E100C16LMPS117.012.08.519,500218507808
CTF48C5CFS2Y81E100C16SMPS117.012.08.519,500218507805
CTU48C5XFS2+TXVY82E100C16LMPS117.012.08.519,300218507792
CTF48C5CFS2Y82E100C16LMPS117.012.08.519,300218507789
CTU48C5XFS2+TXVY81E080C20LMPS117.012.08.519,300218507782
CTU48C5XFS2+TXVY81E080C20SMPS117.012.08.519,300218507779
CTF48C5CFS2Y81E080C20LMPS117.012.08.519,300218507776
CTF48C5CFS2Y81E080C20SMPS117.012.08.519,300218507774
CTU48C5XFS2+TXVY82E080C16LMPS117.012.08.519,300218507766
CTF48C5CFS2Y82E080C16LMPS117.012.08.519,300218507763
CTU48C5XFS2+JMVT16CC2N1+TXV-17.012.08.519,300218507755
CTF48C5CFS2+JMVT16CC2N1-17.012.08.519,300218507752
CTU48C5XFS2+JMC16C2SN1+TXV-17.012.08.519,300218507749
CTF48C5CFS2+JMC16C2SN1-17.012.08.519,300218507746
CTU48C5XFS2+TXVY81E120C16LMPS117.012.08.519,100218507744
CTU48C5XFS2+TXVY81E120C16SMPS117.012.08.519,100218507741
CTF48C5CFS2Y81E120C16LMPS117.012.08.519,100218507738
CTF48C5CFS2Y81E120C16SMPS117.012.08.519,100218507735
CTU48C5XFS2+JMVT17CC2N1+TXV-17.012.08.519,100218507732
CTF48C5CFS2+JMVT17CC2N1-17.012.08.519,100218507730
CTU48C5XFS2+JMC17C2SN1+TXV-17.012.08.519,100218507727
CTF48C5CFS2+JMC17C2SN1-17.012.08.519,100218507724
CTU48C5XFS2+JME12C2SN2+TXV-17.012.08.519,300218636797
CTF48C5CFS2+JME12C2SN2-17.012.08.519,300218636796
CTF48C5CFS1Y82E120C20LMPS117.012.08.119,400217017125
Yearly running cost in 10 large cities$946-$2,575

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the York YH636E2S11?
The York YH636E2S11 is rated at up to 17.0 SEER2 and 12.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 496 certified matchups SEER2 ranges from 15.2-17.0.
Is the York YH636E2S11 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the York YH636E2S11 cost to run per year?
At its rated efficiency it costs about $946-$2,575 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,173 in Phoenix and $2,156 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the York YH636E2S11?
ENERGY STAR lists 496 certified combinations for this outdoor unit. The highest-rated ones use CTF48C5CFS1+JMET12CS2N1, CTU48C5XFS1+JMET12CS2N1+TXV, CTF48C5CFS1+JMC16C2SN1.
What refrigerant does the York YH636E2S11 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,167/yrYou save $607/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump York YH636E2S11
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,167
Current system, per year
$1,773
You save per year
$607
Payback
21.4 years
Net after 10 years
-$6,934

Cooling $708Heating $459Electricity used: 7,292 kWhSaved vs. a minimum-efficiency heat pump: $195

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 5, 2026. How we use the data.