3-ton central heat pump · ECHELON

Coleman HC19B3621

Average cooling efficiency and below average heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #171 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,151 a year to run in a mixed climate like Atlanta.

SEER2
17.0 Cooling efficiency over a season
Average · beats 49%
HSPF2
7.8 Heating efficiency over a season
Below average · beats 5%
EER2
12.0 Cooling efficiency on a 95°F day
Average · beats 64%
Heat at 5°F
18,400 BTU/h52% of its 47°F output
Average · beats 51%

A good fit if…

  • You want a choice of indoor units - 27 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications3 ton, R-410A
General
BrandColeman
Outdoor unit modelHC19B3621
SeriesECHELON
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJune 7, 2023
Last certifiedJuly 7, 2026
Cooling
SEER2Seasonal efficiency, higher is better17.0 (range 16.0-17.0)
EER2Efficiency at 95°F outdoors11.7-12.5
Cooling capacity34,600-35,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8
Capacity at 47°F34,800-35,400 BTU/h
Capacity at 17°F22,800-23,200 BTU/h
Capacity at 5°F17,900-18,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.80-2.06
ENERGY STAR cold climateNo
Heating output as it gets colder52% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with XAHC60GBCN1 at the standard test temperatures, in BTU/h:

Certified matchups27 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
XAHC60GBCN1TM8Y120C20MP1117.012.07.818,000210296094
XAHC60GBCN1TM8Y100C20MP1117.012.07.818,000210296098
XAHC60GBCN1TM8E100C20MP1117.012.07.818,000210296110
XAHC60GBCN1TMLE100C20MP1117.012.07.818,000210296114
XAHC60GBCN1TM8E120C20MP1117.012.07.818,000210296252
XAHC60GBCN1TMLE120C20MP1117.012.07.818,000210296256
XAHC60GBCN1TM8E080C20MP1117.012.07.818,300210296952
XAHC60GBCN1TMLE080C20MP1117.012.07.818,300210296956
XAFC60GBCN1TM8Y120C20MP1117.012.57.818,000210296700
XAFC60GBCN1TM8Y100C20MP1117.012.57.818,000210296708
XAFC60GBCN1TM8Y100C16MP1117.012.57.817,900209198729
XAFC60GBCN1TM8Y080C16MP1117.012.57.817,900209198733
XAFC60GBCN1TPLC100C20MP1317.012.07.818,000209204461
XAFC60GBCN1CPLC120C20MP1317.012.07.818,000209204470
XAFC60GBCN1TPLC120C20MP1317.012.07.818,000209204465
XAFC60GBCN1Z8ET120C20LMPS117.011.77.817,900211770255
XAFC60GBCN1CPLC100C20MP1317.012.07.818,000211726160
XAFC60GBCN1TM8E080C20MP1116.012.57.818,000210297753
XAFC60GBCN1TMLE080C20MP1116.012.57.818,000210297761
XAFC60GBCN1TM8E100C20MP1116.012.57.818,000210296724
XAFC60GBCN1TMLE100C20MP1116.012.57.818,000210296732
XAFC60GBCN1TM8E120C20MP1116.012.57.818,100210297298
XAFC60GBCN1TMLE120C20MP1116.012.57.818,100210297306
XAFC60GBCN1CPLC080C16MP1316.012.07.818,400209195106
XAFC60GBCN1TPLC100C16MP1316.012.07.818,400209195099
XAFC60GBCN1CPLC100C16MP1316.012.07.818,400209195110
XAFC60GBCN1TPLC080C16MP1316.012.07.818,400209195090
Yearly running cost in 10 large cities$971-$2,800

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Coleman HC19B3621?
The Coleman HC19B3621 is rated at up to 17.0 SEER2 and 12.0 EER2 for cooling and up to 7.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 27 certified matchups SEER2 ranges from 16.0-17.0.
Is the Coleman HC19B3621 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Coleman HC19B3621 cost to run per year?
At its rated efficiency it costs about $971-$2,800 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,225 in Phoenix and $2,361 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Coleman HC19B3621?
ENERGY STAR lists 27 certified combinations for this outdoor unit. The highest-rated ones use XAHC60GBCN1, XAFC60GBCN1.
What refrigerant does the Coleman HC19B3621 use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,230/yrYou save $578/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Coleman HC19B3621
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,230
Current system, per year
$1,808
You save per year
$578
Payback
22.5 years
Net after 10 years
-$7,222

Cooling $725Heating $505Electricity used: 7,688 kWhSaved vs. a minimum-efficiency heat pump: $157

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 7, 2026. How we use the data.