HVAC Rated

3-ton central heat pump · LX SERIES

Coleman XH536E2S11

Below average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #233 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,054 a year to run in a mixed climate like Atlanta.

SEER2
16.0 Cooling efficiency over a season
Below average · beats 26%
HSPF2
8.1 Heating efficiency over a season
Below average · beats 20%
EER2
11.7 Cooling efficiency on a 95°F day
Average · beats 43%
Heat at 5°F
18,400 BTU/h58% of its 47°F output
Excellent · beats 97%

A good fit if…

  • You want a choice of indoor units - 1,364 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.

Calculate my running cost

Details

Specifications3 ton, R-454B
General
BrandColeman
Also sold asLuxaire, CHAMPION HEATING AND COOLING, Fraser-Johnston, Johnson Controls, Kenmore
Outdoor unit modelXH536E2S11
SeriesLX SERIES
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerTwo-stage
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceSeptember 5, 2024
Last certifiedAugust 5, 2026
Cooling
SEER2Seasonal efficiency, higher is better16.0 (range 15.2-16.0)
EER2Efficiency at 95°F outdoors10.0-12.0
Cooling capacity32,400-35,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.1
Capacity at 47°F30,600-32,800 BTU/h
Capacity at 17°F20,400-22,000 BTU/h
Capacity at 5°F17,000-18,400 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.44
ENERGY STAR cold climateNo
Heating output as it gets colder58% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CTM48C5CFS1 at the standard test temperatures, in BTU/h:

Certified matchups1,364 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 1,364 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CTM48C5CFS1Z8VT080C16SMPC116.011.78.118,000217445048
CTM48C5CFS1Z8VT100C16SMPC116.011.78.117,900217445049
CTF48C5CFS1Z8VT080C16SMPC116.011.08.118,000217445050
CTU48C5XFS1+TXVZ8VT080C16SMPC116.011.08.118,000217445051
CTF48C5CFS1Z8VT100C16SMPC116.011.08.118,100217445052
CTU48C5XFS1+TXVZ8VT100C16SMPC116.011.08.118,100217445053
CTF48C5CFS1Z8VT080C16SMPC116.011.08.118,000217444740
CTM48C5CFS1Z8VT080C16SMPC116.011.78.118,000217444738
CTU48C5XFS1+TXVZ8VT080C16SMPC116.011.08.118,000217444741
CTM48C5CFS1Z8VT100C16SMPC116.011.78.117,900217444739
CTU48C5XFS1+TXVZ8VT100C16SMPC116.011.08.118,100217444743
CTF48C5CFS1Z8VT100C16SMPC116.011.08.118,100217444742
CTM48C5CFS1Z8VT080C16SMPC116.011.78.118,000217444800
CTM48C5CFS1Z8VT100C16SMPC116.011.78.117,900217444801
CTF48C5CFS1Z8VT080C16SMPC116.011.08.118,000217444802
CTF48C5CFS1Z8VT100C16SMPC116.011.08.118,100217444804
CTU48C5XFS1+TXVZ8VT080C16SMPC116.011.08.118,000217444803
CTU48C5XFS1+TXVZ8VT100C16SMPC116.011.08.118,100217444805
CTM48C5CFS1Z8VT080C16SMPC116.011.78.118,000217444862
CTM48C5CFS1Z8VT100C16SMPC116.011.78.117,900217444863
CTF48C5CFS1Z8VT080C16SMPC116.011.08.118,000217444864
CTU48C5XFS1+TXVZ8VT080C16SMPC116.011.08.118,000217444865
CTF48C5CFS1Z8VT100C16SMPC116.011.08.118,100217444866
CTU48C5XFS1+TXVZ8VT100C16SMPC116.011.08.118,100217444867
CTM48C5CFS1Z8VT080C16SMPC116.011.78.118,000217444924
CTF48C5CFS1Z8VT080C16SMPC116.011.08.118,000217444926
CTU48C5XFS1+TXVZ8VT080C16SMPC116.011.08.118,000217444927
CTM48C5CFS1Z8VT100C16SMPC116.011.78.117,900217444925
CTF48C5CFS1Z8VT100C16SMPC116.011.08.118,100217444928
CTU48C5XFS1+TXVZ8VT100C16SMPC116.011.08.118,100217444929
CTM48C5CFS1Z8VT080C16SMPC116.011.78.118,000217444986
CTF48C5CFS1Z8VT080C16SMPC116.011.08.118,000217444988
CTU48C5XFS1+TXVZ8VT080C16SMPC116.011.08.118,000217444989
CTM48C5CFS1Z8VT100C16SMPC116.011.78.117,900217444987
CTU48C5XFS1+TXVZ8VT100C16SMPC116.011.08.118,100217444991
CTF48C5CFS1Z8VT100C16SMPC116.011.08.118,100217444990
CTU48C5XFS2+TXVZ8VT100C16SMPC116.011.08.118,100218519345
CTU48C5XFS2+TXVZ8VT100C16SMPC116.011.08.118,100218519344
CTU48C5XFS2+TXVZ8VT100C16SMPC116.011.08.118,100218519343
CTU48C5XFS2+TXVZ8VT100C16SMPC116.011.08.118,100218519342
CTF48C5CFS2Z8VT100C16SMPC116.011.08.118,100218519341
CTF48C5CFS2Z8VT100C16SMPC116.011.08.118,100218519340
CTF48C5CFS2Z8VT100C16SMPC116.011.08.118,100218519339
CTF48C5CFS2Z8VT100C16SMPC116.011.08.118,100218519338
CTU48C5XFS2+TXVZ8VT080C16SMPC116.011.08.118,000218519337
CTU48C5XFS2+TXVZ8VT080C16SMPC116.011.08.118,000218519336
CTU48C5XFS2+TXVZ8VT080C16SMPC116.011.08.118,000218519335
CTU48C5XFS2+TXVZ8VT080C16SMPC116.011.08.118,000218519334
CTF48C5CFS2Z8VT080C16SMPC116.011.08.118,000218519333
CTF48C5CFS2Z8VT080C16SMPC116.011.08.118,000218519332
CTF48C5CFS2Z8VT080C16SMPC116.011.08.118,000218519331
CTF48C5CFS2Z8VT080C16SMPC116.011.08.118,000218519330
CTM48C5CFS2Z8VT100C16SMPC116.011.78.117,900218518927
CTM48C5CFS2Z8VT100C16SMPC116.011.78.117,900218518926
CTM48C5CFS2Z8VT100C16SMPC116.011.78.117,900218518925
CTM48C5CFS2Z8VT100C16SMPC116.011.78.117,900218518924
CTM48C5CFS2Z8VT080C16SMPC116.011.78.118,000218518923
CTM48C5CFS2Z8VT080C16SMPC116.011.78.118,000218518922
CTM48C5CFS2Z8VT080C16SMPC116.011.78.118,000218518921
CTM48C5CFS2Z8VT080C16SMPC116.011.78.118,000218518920
Yearly running cost in 10 large cities$985-$2,485

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Coleman XH536E2S11?
The Coleman XH536E2S11 is rated at up to 16.0 SEER2 and 11.7 EER2 for cooling and up to 8.1 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 1364 certified matchups SEER2 ranges from 15.2-16.0.
Is the Coleman XH536E2S11 good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Coleman XH536E2S11 cost to run per year?
At its rated efficiency it costs about $985-$2,485 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,193 in Phoenix and $2,061 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Coleman XH536E2S11?
ENERGY STAR lists 1364 certified combinations for this outdoor unit. The highest-rated ones use CTM48C5CFS1, CTF48C5CFS1, CTU48C5XFS1+TXV.
What refrigerant does the Coleman XH536E2S11 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,173/yrYou save $523/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Coleman XH536E2S11
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,173
Current system, per year
$1,697
You save per year
$523
Payback
23.9 years
Net after 10 years
-$7,269

Cooling $739Heating $434Electricity used: 7,334 kWhSaved vs. a minimum-efficiency heat pump: $123

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of August 5, 2026. How we use the data.