HVAC Rated

3-ton central heat pump · BHP17 SERIES

Blueridge BHP17L36P-**A

Average cooling and heating efficiency for a 3-ton central heat pump, but not rated for cold climates.

Ranks #176 of 302 3 ton central heat pumps for cooling efficiency, and costs about $1,060 a year to run in a mixed climate like Atlanta.

SEER2
16.8 Cooling efficiency over a season
Average · beats 45%
HSPF2
8.7 Heating efficiency over a season
Average · beats 47%
EER2
13.5 Cooling efficiency on a 95°F day
Excellent · beats 95%
Heat at 5°F
19,100 BTU/h50% of its 47°F output
Excellent · beats 92%

A good fit if…

  • You want a choice of indoor units - 131 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.
  • Comfort and noise matter - a single-stage compressor runs only full-on or off.

Calculate my running cost

Details

Specifications3 ton, R-410A
General
BrandBlueridge
Outdoor unit modelBHP17L36P-**A
SeriesBHP17 SERIES
TypeCentral heat pump
Nominal size3 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceJanuary 6, 2022
Last certifiedOctober 27, 2025
Cooling
SEER2Seasonal efficiency, higher is better16.8 (range 15.2-16.8)
EER2Efficiency at 95°F outdoors12.2-13.5
Cooling capacity35,000-36,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better7.8-8.7
Capacity at 47°F32,400-36,000 BTU/h
Capacity at 17°F21,400-23,800 BTU/h
Capacity at 5°F16,800-19,100 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.08-2.34
ENERGY STAR cold climateNo
Heating output as it gets colder50% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BC748CCT-0*+TDR at the standard test temperatures, in BTU/h:

Certified matchups131 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 131 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
BC748CCT-0*+TDRBG801UH090CE2016.813.57.816,800214713501
BC748DCT-0*+TDRBG80G1DF110CE2016.613.08.718,800214713481
BH1P51C*+TDR+TXVBG801UH090CE2016.613.58.017,400211736686
BC742HCT-0*+TDRBG921UH110CE1616.613.58.017,900214713449
BC742HCT-0*+TDRBG961UH110CE2016.613.58.017,800214713452
BC748CCT-0*+TDRBG801UH110CE2016.613.58.017,000214713502
BC751HCT-0*+TDRBG801UH090CE2016.613.58.017,400214713464
BC4X36B+TDRBG801UH090BE1616.613.57.816,800210441335
BC1P36B+TDR+TXVBG801UH090BE1616.613.57.816,800210441308
BC1P36A+TDR+TXVBG801UH090BE1616.613.57.816,800210325358
BC748CCT-0*+TDRBG921UH090CE1616.613.57.816,800214713504
BC748CCT-0*+TDRBG921UH110CE1616.613.57.817,000214713505
BC748CCT-0*+TDRBG921UH110CE2016.613.57.816,800214713506
BC748CCT-0*+TDRBG961UH090CE1616.613.57.817,000214713507
BC748CCT-0*+TDRBG961UH110CE2016.613.57.817,000214713508
BC736CBT-0*+TDRBG801UH090BE1616.613.57.816,800214713493
BH1P51C*+TDR+TXVBG801UH110CE2016.413.08.117,400211736699
BC742HCT-0*+TDRBG801UH110CE2016.413.58.118,000214713446
BC742HBT-0*+TDRBG801UH090BE1616.413.08.118,300214713439
BC751HCT-0*+TDRBG801UH110CE2016.413.08.117,400214713465
BH1P51C*+TDR+TXVBG921UH110CE2016.413.08.017,300211736762
BH1P51C*+TDR+TXVBG961UH110CE2016.413.08.017,500211736794
BC742HCT-0*+TDRBG921UH110CE2016.413.58.017,900214713450
BC742HCT-0*+TDRBG961UH090CE1616.413.58.018,100214713451
BC742HCT-0*+TDRBG801UH090CE2016.413.58.017,900214713445
BC751HCT-0*+TDRBG921UH110CE2016.413.08.017,300214713469
BC751HCT-0*+TDRBG961UH110CE2016.413.08.017,500214713471
BC742HCT-0*+TDRBG921UH090CE1616.413.58.017,900214713448
BC4X36B+TDRBG802UH090BE1616.413.07.817,000210441332
BC1P36B+TDR+TXVBG802UH090BE1616.413.07.817,000210441305
BC1P36A+TDR+TXVBG802UH090BE1616.413.07.817,000210325302
BC4X36B+TDRBG802UH090BE1216.413.07.817,000210441331
BC1P36B+TDR+TXVBG802UH090BE1216.413.07.817,000210441304
BC1P36A+TDR+TXVBG802UH090BE1216.413.07.817,000210325307
BH1P51C*+TDR+TXVBG921UH110CE1616.413.07.817,400211736746
BC748CCT-0*+TDRBG921UH090CE1216.413.57.817,000214713503
BC751HCT-0*+TDRBG921UH110CE1616.413.07.817,400214713468
BC750/60CCT-0*+TDRBG801UH090CE2016.413.07.817,000214713511
BC736CBT-0*+TDRBG802UH090BE1216.413.07.817,000214713490
BC736CBT-0*+TDRBG802UH090BE1616.413.07.817,000214713491
BC748DCT-0*+TDRBG96G1DF090CE1616.213.08.719,100214713482
BC748DCT-0*+TDRBG96G1DF110CE2016.213.08.718,900214713483
BE5V42MA4X-16.213.08.117,400211174420
BC742HBT-0*+TDRBG802UH090BE1216.213.08.118,500214713436
BC742HBT-0*+TDRBG802UH090BE1616.213.08.118,300214713437
BC730/36DCT-0*+TDRBG80G1DF110CE2016.213.58.118,400214713477
BAH7V42PT-0-16.213.08.117,400214866150
BH1P48B*+TDR+TXVBG802UH090BE1616.213.08.017,200211736314
BH1P48B*+TDR+TXVBG801UH090BE1616.213.08.017,200211736410
BH1P51C*+TDR+TXVBG961UH090CE1616.213.08.017,500211736777
BH1P48B*+TDR+TXVBG802UH090BE1216.213.08.017,400211736299
BC748HBT-0*+TDRBG802UH090BE1216.213.08.017,400214713455
BC748HBT-0*+TDRBG802UH090BE1616.213.08.017,200214713456
BC748HBT-0*+TDRBG801UH090BE1616.213.08.017,200214713458
BC742HCT-0*+TDRBG921UH090CE1216.213.08.018,100214713447
BC748CCT-0*+TDRBG802UH110CV2016.213.58.017,200214713509
BC751HCT-0*+TDRBG961UH090CE1616.213.08.017,500214713470
BC1P36A+TDR+TXVBG802UH090BV1616.213.07.817,200210325313
BC4X36B+TDRBG802UH090BV1616.213.07.817,200210441339
BC4X36B+TDRBG801UH070BE1216.213.07.817,200210441334
Yearly running cost in 10 large cities$1,004-$2,488

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Blueridge BHP17L36P-**A?
The Blueridge BHP17L36P-**A is rated at up to 16.8 SEER2 and 13.5 EER2 for cooling and up to 8.7 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 131 certified matchups SEER2 ranges from 15.2-16.8.
Is the Blueridge BHP17L36P-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 3-ton model.
How much does the Blueridge BHP17L36P-**A cost to run per year?
At its rated efficiency it costs about $1,004-$2,488 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,210 in Phoenix and $2,058 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Blueridge BHP17L36P-**A?
ENERGY STAR lists 131 certified combinations for this outdoor unit. The highest-rated ones use BC748CCT-0*+TDR, BC748DCT-0*+TDR, BH1P51C*+TDR+TXV.
What refrigerant does the Blueridge BHP17L36P-**A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,187/yrYou save $630/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Blueridge BHP17L36P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,187
Current system, per year
$1,817
You save per year
$630
Payback
21.4 years
Net after 10 years
-$7,199

Cooling $754Heating $433Electricity used: 7,418 kWhSaved vs. a minimum-efficiency heat pump: $201

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 3 ton models

See all 302 3 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.