2-ton central heat pump · SPHP Series
AC Pro SPHP-Z-V024BB
Very good cooling and heating efficiency for a 2-ton central heat pump, and certified for cold climates.
Ranks #79 of 331 2 ton central heat pumps for cooling efficiency, and costs about $667 a year to run in a mixed climate like Atlanta.
- SEER2
- 18.6 Cooling efficiency over a seasonVery good · beats 79%
- HSPF2
- 10.0 Heating efficiency over a seasonVery good · beats 84%
- EER2
- 12.0 Cooling efficiency on a 95°F dayAverage · beats 64%
- Heat at 5°F
- 21,600 BTU/h86% of its 47°F outputAverage · beats 67%
A good fit if…
- You want low cooling bills - its SEER2 beats 79% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 21,600 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | AC Pro |
| Outdoor unit model | SPHP-Z-V024BB |
| Series | SPHP Series |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | November 30, 2024 |
| Last certified | September 30, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 18.6 (range 16.0-18.6) |
| EER2Efficiency at 95°F outdoors | 10.0-12.0 |
| Cooling capacity | 23,000-24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.9-10.0 |
| Capacity at 47°F | 24,000-26,000 BTU/h |
| Capacity at 17°F | 18,000-20,800 BTU/h |
| Capacity at 5°F | 20,000-21,600 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.80-2.14 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with AIRH-Z-V024V08C at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| AIRH-Z-V024V08C · cold climate | - | 18.6 | 12.0 | 10.0 | 20,600 | 216497963 |
| AIRH-Y-V02408CB · cold climate | - | 18.3 | 11.7 | 10.0 | 21,600 | 218620814 |
| COIL-Y-1824BMTB · cold climate | FURN-M-R2B60V12A | 17.8 | 10.8 | 9.2 | 20,000 | 218471426 |
| SMAH-Y-24EMBB · cold climate | - | 17.5 | 10.8 | 9.2 | 20,000 | 217284582 |
| COIL-Y-1824AMTB · cold climate | FURN-M-L1A60V12A | 16.3 | 10.2 | 9.1 | 20,000 | 218471439 |
| COIL-Y-1824AMTB · cold climate | FURN-M-L1A40V12A | 16.0 | 10.0 | 8.9 | 20,000 | 218471438 |
Yearly running cost in 10 large cities
- Phoenix, AZ$742/yr
- Miami, FL$606/yr
- Houston, TX$665/yr
- Atlanta, GA$667/yr
- Los Angeles, CA$648/yr
- New York, NY$1,587/yr
- Chicago, IL$1,287/yr
- Denver, CO$1,069/yr
- Seattle, WA$656/yr
- Minneapolis, MN$1,323/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the AC Pro SPHP-Z-V024BB?
- The AC Pro SPHP-Z-V024BB is rated at up to 18.6 SEER2 and 12.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 6 certified matchups SEER2 ranges from 16.0-18.6.
- Is the AC Pro SPHP-Z-V024BB good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 21,600 BTU/h at 5°F with a COP of 2.14, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
- How much does the AC Pro SPHP-Z-V024BB cost to run per year?
- At its rated efficiency it costs about $606-$1,587 a year in electricity in large U.S. cities, depending on climate and local rates - for example $742 in Phoenix and $1,323 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the AC Pro SPHP-Z-V024BB?
- ENERGY STAR lists 6 certified combinations for this outdoor unit. The highest-rated ones use AIRH-Z-V024V08C, AIRH-Y-V02408CB, COIL-Y-1824BMTB.
- What refrigerant does the AC Pro SPHP-Z-V024BB use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- MOOVAIR MSHMA24R2AN1 · cold climate18.6 SEER2 · 10.5 HSPF2
- AproDr AHU3G-24HFN-B · cold climate18.6 SEER2 · 10.0 HSPF2
- Midea MO1HE-H24B-2A · cold climate18.6 SEER2 · 10.5 HSPF2
- Blueridge BMSAH24HHC · cold climate18.6 SEER2 · 10.0 HSPF2
- Mainline ML24HP230LMNTH-O · cold climate18.6 SEER2 · 10.5 HSPF2
- Blueridge BNG3A24UCN · cold climate18.6 SEER2 · 10.0 HSPF2
- Innovair SHV24H2BA · cold climate18.6 SEER2 · 10.5 HSPF2
- KEEN Home KEENHYDHP24AA · cold climate18.6 SEER2 · 10.0 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.