Excellent cooling efficiency and below average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.
Ranks #30 of 331 2 ton central heat pumps for cooling efficiency, and costs about $703 a year to run in a mixed climate like Atlanta.
- SEER2
- 20.0 Cooling efficiency over a seasonExcellent · beats 94%
- HSPF2
- 8.5 Heating efficiency over a seasonBelow average · beats 38%
- EER2
- 12.6 Cooling efficiency on a 95°F dayVery good · beats 84%
- Heat at 5°F
- 17,000 BTU/h61% of its 47°F outputAverage · beats 65%
A good fit if…
- You want low cooling bills - its SEER2 beats 94% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 432 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You mainly need heat - its HSPF2 is below average for central heat pumps.
Details
Specifications
| General | |
|---|---|
| Brand | AC Pro |
| Also sold as | SINCLAIR AIR CONDITIONING, Blueridge |
| Outdoor unit model | BH719M36P-**A |
| Series | BH719M Series |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | June 3, 2025 |
| Last certified | September 30, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 20.0 (range 15.2-20.0) |
| EER2Efficiency at 95°F outdoors | 11.0-13.2 |
| Cooling capacity | 21,600-35,800 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-8.5 |
| Capacity at 47°F | 22,800-36,000 BTU/h |
| Capacity at 17°F | 14,500-21,600 BTU/h |
| Capacity at 5°F | 13,600-17,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.48-2.12 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BC742DBT-**+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 432 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| BC742DBT-**+TDR | B97DR702V4B | 20.0 | 12.6 | 8.5 | 14,700 | 217547519 |
| BC724[C,U]BT-**+TDR | B97UR702V3B | 20.0 | 13.2 | 8.5 | 16,400 | 217547559 |
| BC742DBT-**+TDR | B97DR702V4B | 20.0 | 12.6 | 8.5 | 14,700 | 217547579 |
| BC724[C,U]BT-**+TDR | B97UR702V3B | 20.0 | 13.2 | 8.5 | 16,400 | 217547499 |
| BC724[C,U]BT-**+TDR | B97UR702V3B | 20.0 | 13.2 | 8.5 | 16,400 | 217547619 |
| BC742DBT-**+TDR | B97DR702V4B | 20.0 | 12.6 | 8.5 | 14,700 | 217547639 |
| BAH7V30PT- | - | 20.0 | 13.0 | 8.2 | 15,800 | 217504673 |
| BAH7V30PT- | - | 20.0 | 13.0 | 8.2 | 15,800 | 217505558 |
| BAH7V30PT- | - | 20.0 | 13.0 | 8.2 | 15,800 | 217505087 |
| BC730[C,U]BT-**+TDR | B97UR702V3B | 20.0 | 13.0 | 8.1 | 13,800 | 217547568 |
| BC730[C,U]BT-**+TDR | B97UR702V3B | 20.0 | 13.0 | 8.1 | 13,800 | 217547508 |
| BC730[C,U]BT-**+TDR | B97UR702V3B | 20.0 | 13.0 | 8.1 | 13,800 | 217547628 |
| BAH7E24PT- | - | 19.5 | 13.0 | 8.5 | 15,600 | 217504441 |
| BAH7E30PT- | - | 19.5 | 13.0 | 8.5 | 15,800 | 217504689 |
| BC724[C,U]AT-**+TDR | B80UR401E3AX | 19.5 | 13.0 | 8.5 | 16,500 | 217504580 |
| BC724[C,U]AT-**+TDR | B80UR601E3AX | 19.5 | 13.0 | 8.5 | 16,500 | 217504582 |
| BAH7E24PT- | - | 19.5 | 13.0 | 8.5 | 15,600 | 217504985 |
| BC724[C,U]AT-**+TDR | B80UR401E3AX | 19.5 | 13.0 | 8.5 | 16,500 | 217505044 |
| BC724[C,U]AT-**+TDR | B80UR601E3AX | 19.5 | 13.0 | 8.5 | 16,500 | 217505045 |
| BAH7E24PT- | - | 19.5 | 13.0 | 8.5 | 15,600 | 217505401 |
| BC724[C,U]AT-**+TDR | B80UR401E3AX | 19.5 | 13.0 | 8.5 | 16,500 | 217505493 |
| BC724[C,U]AT-**+TDR | B80UR601E3AX | 19.5 | 13.0 | 8.5 | 16,500 | 217505495 |
| BAH7E30PT- | - | 19.5 | 13.0 | 8.5 | 15,800 | 217505564 |
| BAH7E30PT- | - | 19.5 | 13.0 | 8.5 | 15,800 | 217505093 |
| BC736[C,U]BT-**+TDR | B97UR702V3B | 19.5 | 13.2 | 8.5 | 15,100 | 217547571 |
| BC736[C,U]BT-**+TDR | B97UR702V3B | 19.5 | 13.2 | 8.5 | 15,100 | 217547511 |
| BC736[C,U]BT-**+TDR | B97UR702V3B | 19.5 | 13.2 | 8.5 | 15,100 | 217547631 |
| BC724[C,U]BT-**+TDR | B80UR902V4B | 19.5 | 13.0 | 8.5 | 16,500 | 217547558 |
| BC724[C,U]BT-**+TDR | B80UR902V4B | 19.5 | 13.0 | 8.5 | 16,500 | 217547498 |
| BC724[C,U]BT-**+TDR | B80UR902V4B | 19.5 | 13.0 | 8.5 | 16,500 | 217547618 |
| BC730[C,U]BT-**+TDR | B97UR402V3BX | 19.5 | 12.8 | 8.1 | 13,900 | 217504625 |
| BC730[C,U]AT-**+TDR | B80UR402V3AX | 19.5 | 13.0 | 8.1 | 13,800 | 217504671 |
| BC730[C,U]BT-**+TDR | B97UR402V3BX | 19.5 | 12.8 | 8.1 | 13,900 | 217505065 |
| BC730[C,U]AT-**+TDR | B80UR402V3AX | 19.5 | 13.0 | 8.1 | 13,800 | 217505086 |
| BC730[C,U]BT-**+TDR | B97UR402V3BX | 19.5 | 12.8 | 8.1 | 13,900 | 217505525 |
| BC730[C,U]AT-**+TDR | B80UR402V3AX | 19.5 | 13.0 | 8.1 | 13,800 | 217505557 |
| BC730[C,U]BT-**+TDR | B80UR902V4B | 19.5 | 12.8 | 8.1 | 13,900 | 217547567 |
| BC730[C,U]BT-**+TDR | B80UR902V4B | 19.5 | 12.8 | 8.1 | 13,900 | 217547507 |
| BC730[C,U]BT-**+TDR | B80UR902V4B | 19.5 | 12.8 | 8.1 | 13,900 | 217547627 |
| BC736[C,U]BT-**+TDR | B97UR402V3BX | 19.0 | 13.0 | 8.5 | 15,200 | 217504068 |
| BC736[C,U]BT-**+TDR | B97UR602V3BX | 19.0 | 13.0 | 8.5 | 15,200 | 217504070 |
| BC736[C,U]AT-**+TDR | B80UR402V3AX | 19.0 | 13.0 | 8.5 | 15,100 | 217504074 |
| BC724[C,U]BT-**+TDR | B80UR902E3B | 19.0 | 13.0 | 8.5 | 16,600 | 217504544 |
| BC724[C,U]BT-**+TDR | B92UR451E3B | 19.0 | 13.0 | 8.5 | 16,600 | 217504550 |
| BC724[C,U]BT-**+TDR | B92UR701E3B | 19.0 | 13.0 | 8.5 | 16,500 | 217504553 |
| BC724[C,U]BT-**+TDR | B97UR452V3B | 19.0 | 13.0 | 8.5 | 16,400 | 217504561 |
| BC724[C,U]BT-**+TDR | B97UR402V3BX | 19.0 | 13.0 | 8.5 | 16,400 | 217504567 |
| BC724[C,U]BT-**+TDR | B97UR602V3BX | 19.0 | 13.0 | 8.5 | 16,400 | 217504569 |
| BC724[C,U]BT-**+TDR | B80UR702E3A | 19.0 | 13.0 | 8.5 | 16,600 | 217504571 |
| BC724[C,U]AT-**+TDR | B80UR702E3A | 19.0 | 13.0 | 8.5 | 16,600 | 217504584 |
| BC724[C,U]AT-**+TDR | B80UR451E3A | 19.0 | 13.0 | 8.5 | 16,200 | 217504586 |
| BC724[C,U]AT-**+TDR | B80UR402V3AX | 19.0 | 13.0 | 8.5 | 16,400 | 217504590 |
| BC736[C,U]BT-**+TDR | B97UR402V3BX | 19.0 | 13.0 | 8.5 | 15,200 | 217504793 |
| BC736[C,U]BT-**+TDR | B97UR602V3BX | 19.0 | 13.0 | 8.5 | 15,200 | 217504794 |
| BC736[C,U]AT-**+TDR | B80UR402V3AX | 19.0 | 13.0 | 8.5 | 15,100 | 217504796 |
| BC724[C,U]BT-**+TDR | B80UR902E3B | 19.0 | 13.0 | 8.5 | 16,600 | 217505030 |
| BC724[C,U]BT-**+TDR | B92UR451E3B | 19.0 | 13.0 | 8.5 | 16,600 | 217505032 |
| BC724[C,U]BT-**+TDR | B92UR701E3B | 19.0 | 13.0 | 8.5 | 16,500 | 217505033 |
| BC724[C,U]BT-**+TDR | B97UR452V3B | 19.0 | 13.0 | 8.5 | 16,400 | 217505036 |
| BC724[C,U]BT-**+TDR | B97UR602V3BX | 19.0 | 13.0 | 8.5 | 16,400 | 217505039 |
Yearly running cost in 10 large cities
- Phoenix, AZ$729/yr
- Miami, FL$567/yr
- Houston, TX$654/yr
- Atlanta, GA$703/yr
- Los Angeles, CA$693/yr
- New York, NY$1,731/yr
- Chicago, IL$1,415/yr
- Denver, CO$1,184/yr
- Seattle, WA$734/yr
- Minneapolis, MN$1,469/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the AC Pro BH719M36P-**A?
- The AC Pro BH719M36P-**A is rated at up to 20.0 SEER2 and 12.6 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 432 certified matchups SEER2 ranges from 15.2-20.0.
- Is the AC Pro BH719M36P-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
- How much does the AC Pro BH719M36P-**A cost to run per year?
- At its rated efficiency it costs about $567-$1,731 a year in electricity in large U.S. cities, depending on climate and local rates - for example $729 in Phoenix and $1,469 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the AC Pro BH719M36P-**A?
- ENERGY STAR lists 432 certified combinations for this outdoor unit. The highest-rated ones use BC742DBT-**+TDR, BC724[C,U]BT-**+TDR, BAH7V30PT-.
- What refrigerant does the AC Pro BH719M36P-**A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Lennox EL19KPV-024-230A20.0 SEER2 · 9.0 HSPF2
- ALLIED 7HP19V36P-**A20.0 SEER2 · 8.5 HSPF2
- DUOHOME DOT-D24HNR8-EA01(J0) · cold climate20.0 SEER2 · 9.4 HSPF2
- Armstrong Air A7HP19V36P-**A20.0 SEER2 · 8.5 HSPF2
- UTL UCHA-24HDCTN2 · cold climate20.0 SEER2 · 9.5 HSPF2
- Century HSA1936V1-**A20.0 SEER2 · 8.5 HSPF2
- UTL UCHA-24HDCT · cold climate20.0 SEER2 · 9.5 HSPF2
- Friedrich FRP18AZ24AJVC · cold climate20.0 SEER2 · 8.5 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.