2-ton central heat pump · Elite EL19KPV SERIES
Lennox EL19KPV-024-230A
Excellent cooling efficiency and average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.
Ranks #29 of 331 2 ton central heat pumps for cooling efficiency, and costs about $672 a year to run in a mixed climate like Atlanta.
- SEER2
- 20.0 Cooling efficiency over a seasonExcellent · beats 94%
- HSPF2
- 9.0 Heating efficiency over a seasonAverage · beats 54%
- EER2
- 13.0 Cooling efficiency on a 95°F dayVery good · beats 89%
- Heat at 5°F
- 17,000 BTU/h60% of its 47°F outputAverage · beats 48%
A good fit if…
- You want low cooling bills - its SEER2 beats 94% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 221 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
Details
Specifications
| General | |
|---|---|
| Brand | Lennox |
| Outdoor unit model | EL19KPV-024-230A |
| Series | Elite EL19KPV SERIES |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | March 26, 2025 |
| Last certified | September 30, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 20.0 (range 15.2-20.0) |
| EER2Efficiency at 95°F outdoors | 11.0-13.4 |
| Cooling capacity | 21,600-24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 7.8-9.0 |
| Capacity at 47°F | 22,800-25,600 BTU/h |
| Capacity at 17°F | 13,300-17,000 BTU/h |
| Capacity at 5°F | 11,700-17,000 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.48-2.04 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CK40DT-42B-**+TDR at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 221 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| CK40DT-42B-**+TDR | EL297DF045XV36B* | 20.0 | 13.0 | 9.0 | 14,500 | 217507615 |
| CK40DT-42B-**+TDR | SLP99DF070XV36B* | 20.0 | 13.0 | 9.0 | 14,500 | 217507617 |
| CK40[C,U]T-24B-**+TDR | EL280UH045E36A* | 20.0 | 13.0 | 8.5 | 16,200 | 217446863 |
| CK40[C,U]T-24A-**+TDR | EL280UH045E36A* | 20.0 | 13.0 | 8.5 | 16,200 | 217446874 |
| CK40[C,U]T-30B-**+TDR | EL280UH045E36A* | 20.0 | 13.0 | 8.2 | 13,700 | 217446928 |
| CK40[C,U]T-30A-**+TDR | EL280UH045E36A* | 20.0 | 13.0 | 8.2 | 13,700 | 217446952 |
| CBK45UHVT-030-230- | - | 20.0 | 13.0 | 8.2 | 15,800 | 217446972 |
| CK40DT-42B-**+TDR | EL297DF070XV48B* | 19.5 | 12.8 | 9.0 | 14,600 | 217507616 |
| CBK48MVT-030-230- | - | 19.5 | 12.8 | 8.5 | 15,500 | 217194130 |
| CK40[C,U]T-36B-**+TDR | ML180UH090V48B* | 19.5 | 12.8 | 8.5 | 15,300 | 217194144 |
| CK40[C,U]T-36A-**+TDR | EL280UH045E36A* | 19.5 | 13.2 | 8.5 | 15,000 | 217194169 |
| CBK45UHET-024-230- | - | 19.5 | 13.0 | 8.5 | 15,600 | 217194646 |
| CK40[C,U]T-24B-**+TDR | EL196UH030XE36B* | 19.5 | 13.0 | 8.5 | 16,300 | 217446839 |
| CK40[C,U]T-24B-**+TDR | ML180UH070V36B* | 19.5 | 13.0 | 8.5 | 16,300 | 217446844 |
| CK40[C,U]T-24B-**+TDR | ML180UH070V48B* | 19.5 | 13.0 | 8.5 | 16,400 | 217446845 |
| CK40[C,U]T-24B-**+TDR | ML180UH090V48B* | 19.5 | 13.0 | 8.5 | 16,600 | 217446847 |
| CK40[C,U]T-24B-**+TDR | ML193UH030XE36B* | 19.5 | 13.0 | 8.5 | 16,200 | 217446848 |
| CK40[C,U]T-24B-**+TDR | SL280UH090V36B* | 19.5 | 13.0 | 8.5 | 16,300 | 217446857 |
| CK40[C,U]T-24B-**+TDR | SL280UH090V48B* | 19.5 | 13.0 | 8.5 | 16,300 | 217446858 |
| CK40[C,U]T-24B-**+TDR | SL280UH090XV48B* | 19.5 | 13.0 | 8.5 | 16,300 | 217446859 |
| CK40[C,U]T-24A-**+TDR | EL180UH040NE36A* | 19.5 | 13.0 | 8.5 | 16,500 | 217446872 |
| CK40[C,U]T-24A-**+TDR | EL180UH060NE36A* | 19.5 | 13.0 | 8.5 | 16,500 | 217446873 |
| CK40[C,U]T-24A-**+TDR | ML180UH070V36A* | 19.5 | 13.0 | 8.5 | 16,300 | 217446882 |
| CBK45UHET-030-230- | - | 19.5 | 13.0 | 8.5 | 15,800 | 217446980 |
| CK40[C,U]T-36B-**+TDR | ML180UH070V48B* | 19.5 | 13.4 | 8.2 | 15,100 | 217194142 |
| CK40[C,U]T-30B-**+TDR | ML180UH070V36B* | 19.5 | 13.0 | 8.2 | 13,800 | 217446896 |
| CK40[C,U]T-30B-**+TDR | SL280UH090V36B* | 19.5 | 13.0 | 8.2 | 13,800 | 217446918 |
| CK40[C,U]T-30B-**+TDR | SLP99UH070XV36B* | 19.5 | 13.0 | 8.2 | 13,800 | 217446926 |
| CK40[C,U]T-30B-**+TDR | EL196UH030XE36B* | 19.5 | 12.8 | 8.1 | 13,800 | 217446889 |
| CK40[C,U]T-30B-**+TDR | ML180UH090V48B* | 19.5 | 12.8 | 8.1 | 14,000 | 217446899 |
| CK40[C,U]T-30B-**+TDR | ML193UH030XE36B* | 19.5 | 13.0 | 8.1 | 13,700 | 217446900 |
| CK40[C,U]T-30B-**+TDR | SL297UH040NV36B* | 19.5 | 12.8 | 8.1 | 13,900 | 217446923 |
| CK40[C,U]T-30B-**+TDR | EL297UH070XV36B* | 19.5 | 13.0 | 8.1 | 13,800 | 217446941 |
| CK40[C,U]T-30A-**+TDR | ML180UH030V36A* | 19.5 | 13.0 | 8.1 | 13,900 | 217446957 |
| CK40[C,U]T-30A-**+TDR | ML180UH045V36A* | 19.5 | 13.0 | 8.1 | 13,800 | 217446962 |
| CK40[C,U]T-30A-**+TDR | ML180UH070V36A* | 19.5 | 13.0 | 8.1 | 13,800 | 217446967 |
| CK40[C,U]T-30A-**+TDR | SL280UH060NV36A* | 19.5 | 13.0 | 8.1 | 13,800 | 217446969 |
| CK40[C,U]T-30B-**+TDR | ML180UH070V48B* | 19.5 | 13.0 | 8.0 | 13,900 | 217446897 |
| CK40[C,U]T-36C-**+TDR | ML297UH090XV36C* | 19.5 | 13.0 | 7.8 | 11,800 | 218695100 |
| CK40[C,U]T-36B-**+TDR | EL196UH030XE36B* | 19.0 | 13.0 | 8.5 | 15,000 | 217194134 |
| CK40[C,U]T-36B-**+TDR | EL280UH090E36B* | 19.0 | 12.8 | 8.5 | 15,400 | 217194137 |
| CK40[C,U]T-36B-**+TDR | ML180UH070V36B* | 19.0 | 13.4 | 8.5 | 15,100 | 217194141 |
| CK40[C,U]T-36B-**+TDR | ML193UH030XE36B* | 19.0 | 13.0 | 8.5 | 15,000 | 217194145 |
| CK40[C,U]T-36B-**+TDR | ML193UH045XE36B* | 19.0 | 12.8 | 8.5 | 15,400 | 217194146 |
| CK40[C,U]T-36B-**+TDR | ML193UH070XE36B* | 19.0 | 13.0 | 8.5 | 15,300 | 217194147 |
| CK40[C,U]T-36B-**+TDR | ML196UH030XE36B* | 19.0 | 13.0 | 8.5 | 15,000 | 217194148 |
| CK40[C,U]T-36B-**+TDR | ML296UH045XV36B* | 19.0 | 13.0 | 8.5 | 15,100 | 217194151 |
| CK40[C,U]T-36B-**+TDR | ML296UH070XV36B* | 19.0 | 13.0 | 8.5 | 15,200 | 217194152 |
| CK40[C,U]T-36B-**+TDR | SL280UH090V36B* | 19.0 | 13.2 | 8.5 | 15,100 | 217194154 |
| CK40[C,U]T-36B-**+TDR | SL297UH040NV36B* | 19.0 | 13.0 | 8.5 | 15,200 | 217194157 |
| CK40[C,U]T-36B-**+TDR | SL297UH060NV36B* | 19.0 | 13.0 | 8.5 | 15,200 | 217194158 |
| CK40[C,U]T-36B-**+TDR | SLP99UH070XV36B* | 19.0 | 13.0 | 8.5 | 15,100 | 217194159 |
| CK40[C,U]T-36A-**+TDR | EL180UH040NE36A* | 19.0 | 13.0 | 8.5 | 15,300 | 217194167 |
| CK40[C,U]T-36A-**+TDR | EL180UH060NE36A* | 19.0 | 13.0 | 8.5 | 15,300 | 217194168 |
| CK40[C,U]T-36A-**+TDR | EL280UH070E36A* | 19.0 | 12.8 | 8.5 | 15,400 | 217194170 |
| CK40[C,U]T-36A-**+TDR | EL280UH070XE36A* | 19.0 | 12.8 | 8.5 | 15,400 | 217194171 |
| CK40[C,U]T-36A-**+TDR | ML180UH030V36A* | 19.0 | 13.2 | 8.5 | 15,100 | 217194172 |
| CK40[C,U]T-36A-**+TDR | ML180UH045V36A* | 19.0 | 13.2 | 8.5 | 15,100 | 217194174 |
| CK40[C,U]T-36A-**+TDR | ML180UH070V36A* | 19.0 | 13.2 | 8.5 | 15,100 | 217194177 |
| CK40[C,U]T-36A-**+TDR | SL280UH060NV36A* | 19.0 | 13.0 | 8.5 | 15,100 | 217194179 |
Yearly running cost in 10 large cities
- Phoenix, AZ$711/yr
- Miami, FL$561/yr
- Houston, TX$638/yr
- Atlanta, GA$672/yr
- Los Angeles, CA$659/yr
- New York, NY$1,637/yr
- Chicago, IL$1,335/yr
- Denver, CO$1,115/yr
- Seattle, WA$689/yr
- Minneapolis, MN$1,382/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Lennox EL19KPV-024-230A?
- The Lennox EL19KPV-024-230A is rated at up to 20.0 SEER2 and 13.0 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 221 certified matchups SEER2 ranges from 15.2-20.0.
- Is the Lennox EL19KPV-024-230A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
- How much does the Lennox EL19KPV-024-230A cost to run per year?
- At its rated efficiency it costs about $561-$1,637 a year in electricity in large U.S. cities, depending on climate and local rates - for example $711 in Phoenix and $1,382 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Lennox EL19KPV-024-230A?
- ENERGY STAR lists 221 certified combinations for this outdoor unit. The highest-rated ones use CK40DT-42B-**+TDR, CK40[C,U]T-24B-**+TDR, CK40[C,U]T-24A-**+TDR.
- What refrigerant does the Lennox EL19KPV-024-230A use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- DUOHOME DOT-D24HNR8-EA01(J0) · cold climate20.0 SEER2 · 9.4 HSPF2
- AC Pro BH719M36P-**A20.0 SEER2 · 8.5 HSPF2
- UTL UCHA-24HDCTN2 · cold climate20.0 SEER2 · 9.5 HSPF2
- ALLIED 7HP19V36P-**A20.0 SEER2 · 8.5 HSPF2
- UTL UCHA-24HDCT · cold climate20.0 SEER2 · 9.5 HSPF2
- Armstrong Air A7HP19V36P-**A20.0 SEER2 · 8.5 HSPF2
- Fujitsu FOP1924MJAYCA · cold climate20.0 SEER2 · 9.5 HSPF2
- Century HSA1936V1-**A20.0 SEER2 · 8.5 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.