HVAC Rated

2-ton central heat pump · Elite EL21KLV SERIES

Lennox EL21KLV-024-230A

Excellent cooling and heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #8 of 331 2 ton central heat pumps for cooling efficiency, and costs about $615 a year to run in a mixed climate like Atlanta.

SEER2
21.0 Cooling efficiency over a season
Excellent · beats 97%
HSPF2
10.2 Heating efficiency over a season
Excellent · beats 91%
EER2
13.5 Cooling efficiency on a 95°F day
Excellent · beats 95%
Heat at 5°F
18,600 BTU/h75% of its 47°F output
Very good · beats 88%

A good fit if…

  • You want low cooling bills - its SEER2 beats 97% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 18,600 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 91% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandLennox
Outdoor unit modelEL21KLV-024-230A
SeriesElite EL21KLV SERIES
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceMarch 7, 2025
Last certifiedSeptember 30, 2026
Cooling
SEER2Seasonal efficiency, higher is better21.0 (range 15.2-21.0)
EER2Efficiency at 95°F outdoors11.2-13.5
Cooling capacity21,600-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.1-10.2
Capacity at 47°F23,600-27,400 BTU/h
Capacity at 17°F18,700-22,400 BTU/h
Capacity at 5°F13,900-18,600 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.70-2.30
ENERGY STAR cold climateYes
Heating output as it gets colder75% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CK40HT-24B-**+TDR at the standard test temperatures, in BTU/h:

Certified matchups178 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 178 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CK40HT-24B-**+TDR · cold climateML197UH030XE36B*21.013.58.218,100218745112
CBK48MVT-030-230- · cold climate-20.512.010.017,900217115278
CBK48MVT-018/024-230- · cold climate-20.513.010.018,600217115280
CBK47UHET-024-230- · cold climate-20.513.09.818,600217121964
CBK47UHET-030-230- · cold climate-20.513.09.817,900217121963
CK40HT-30A-**+TDREL280UH045E36A*20.512.59.016,700217443193
CBK45UHVT-030-230- · cold climate-20.513.08.517,800217121962
CK40DT-30/36C-**+TDRSLP99DF090XV36C*20.513.08.516,200217443154
CK40[C,U]T-30B-**+TDR · cold climateSL297UH040NV36B*20.012.810.017,700217115288
CK40[C,U]T-30A-**+TDR · cold climateEL180UH040NE36A*20.012.69.817,600217121529
CK40[C,U]T-30A-**+TDR · cold climateEL180UH060NE36A*20.012.69.817,600217121530
CBK45UHVT-024-230--20.013.09.817,300217443134
CK40[C,U]T-30A-**+TDR · cold climateML180UH070V36A*20.013.09.617,400217121548
CK40[C,U]T-30B-**+TDR · cold climateML180UH070V36B*20.013.09.617,400217121549
CK40[C,U]T-30B-**+TDR · cold climateML180UH090V48B*20.012.69.617,700217121553
CK40HT-30B-**+TDR · cold climateSL280UH090V36B*20.013.09.417,000217443174
CK40HT-30B-**+TDR · cold climateSL297UH040NV36B*20.013.09.417,100217443176
CK40HT-30B-**+TDR · cold climateSL297UH060NV36B*20.013.09.417,100217443177
CK40HT-30B-**+TDR · cold climateSLP99UH070XV36B*20.013.09.417,000217443178
CK40HT-30B-**+TDREL297UH070XV36B*20.013.09.417,000217443185
CK40HT-30B-**+TDR · cold climateML180UH070V36B*20.013.09.016,900217443162
CK40HT-30B-**+TDR · cold climateML180UH090V48B*20.013.09.017,100217443166
CK40HT-30A-**+TDRSL280UH060NV36A*20.012.59.017,100217443201
CK40DT-30/36B-**+TDRSL280DF090V48B*20.012.58.516,300217443143
CK40DT-30/36B-**+TDREL297DF045XV36B*20.012.58.516,200217443144
CK40DT-30/36B-**+TDRSLP99DF070XV36B*20.012.58.516,300217443145
CK40HT-30B-**+TDR · cold climateML180UH070V48B*20.013.08.516,900217443164
CK40HT-24A-**+TDR · cold climateEL180UH040NE36A*20.013.08.517,500217443186
CK40HT-24A-**+TDR · cold climateEL280UH070XE36A*20.013.08.517,600217443187
CK40HT-24A-**+TDR · cold climateEL180UH060NE36A*20.013.08.517,500217443188
CK40HT-24A-**+TDR · cold climateEL280UH070E36A*20.013.08.517,600217443189
CK40HT-24B-**+TDR · cold climateML197UH060XE36B*20.013.58.518,400218747720
CK40HT-24A-**+TDR · cold climateML180UH030V36A*20.013.08.217,300217443190
CBK45UHET-024-230--19.513.010.217,300217443135
CK40[C,U]T-30A-**+TDR · cold climateSL280UH060NV36A*19.513.010.017,600217115281
CK40[C,U]T-30B-**+TDR · cold climateSL297UH060NV36B*19.512.89.817,700217115289
CK40[C,U]T-30A-**+TDR · cold climateEL280UH045E36A*19.513.09.817,300217121537
CK40[C,U]T-30A-**+TDR · cold climateEL280UH070E36A*19.512.69.817,700217121538
CK40[C,U]T-30A-**+TDR · cold climateEL280UH070XE36A*19.512.69.817,700217121539
CK40[C,U]T-30B-**+TDR · cold climateML193UH045XE36B*19.512.69.817,700217121554
CK40[C,U]T-30B-**+TDR · cold climateML193UH070XE36B*19.512.89.817,700217121555
CK40[C,U]T-30A-**+TDR · cold climateML180UH030V36A*19.513.09.617,400217121544
CK40[C,U]T-30B-**+TDR · cold climateML296UH070XV36B*19.512.89.617,500217121560
CK40[C,U]T-30A-**+TDR · cold climateML180UH045V36A*19.513.09.517,300217121545
CK40[C,U]T-30B-**+TDR · cold climateML296UH045XV36B*19.512.89.517,400217121559
CK40HT-30B-**+TDR · cold climateSL280UH090V48B*19.513.09.417,000217443175
CK40HT-30B-**+TDR · cold climateSL280UH090XV48B*19.513.09.417,000217443179
CK40HT-30B-**+TDR · cold climateEL297UH045XV36B*19.513.09.417,100217443184
CK40[C,U]T-30B-**+TDR · cold climateML180UH070V48B*19.513.09.017,400217121550
CK40HT-30B-**+TDR · cold climateML193UH045XE36B*19.513.09.017,200217443167
CK40HT-30B-**+TDR · cold climateML193UH070XE36B*19.513.09.017,100217443168
CK40HT-30B-**+TDR · cold climateML296UH045XV36B*19.513.09.016,900217443171
CK40HT-30B-**+TDR · cold climateSL280UH080NV48B*19.513.09.017,200217443173
CK40HT-30A-**+TDREL280UH070E36A*19.512.09.017,200217443194
CK40HT-30A-**+TDREL280UH070XE36A*19.512.09.017,200217443195
CK40HT-30A-**+TDRSL280UH070V36A*19.512.59.017,100217443202
CK40HT-30A-**+TDRSL280UH070XV36A*19.512.59.017,100217443203
CK40[C,U]T-24B-**+TDRSL297UH040NV36B*19.513.08.514,200217443096
CK40[C,U]T-24B-**+TDRSL280UH090V36B*19.513.08.514,100217443125
CK40DT-30/36B-**+TDRML193DF045XE36B*19.512.58.516,300217443138
Yearly running cost in 10 large cities$525-$1,490

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Lennox EL21KLV-024-230A?
The Lennox EL21KLV-024-230A is rated at up to 21.0 SEER2 and 13.5 EER2 for cooling and up to 10.2 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 178 certified matchups SEER2 ranges from 15.2-21.0.
Is the Lennox EL21KLV-024-230A good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 18,600 BTU/h at 5°F with a COP of 2.30, so it is still 2.3 times as efficient as electric resistance heat at that temperature.
How much does the Lennox EL21KLV-024-230A cost to run per year?
At its rated efficiency it costs about $525-$1,490 a year in electricity in large U.S. cities, depending on climate and local rates - for example $659 in Phoenix and $1,254 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Lennox EL21KLV-024-230A?
ENERGY STAR lists 178 certified combinations for this outdoor unit. The highest-rated ones use CK40HT-24B-**+TDR, CBK48MVT-030-230-, CBK48MVT-018/024-230-.
What refrigerant does the Lennox EL21KLV-024-230A use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $660/yrYou save $563/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Lennox EL21KLV-024-230A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$660
Current system, per year
$1,223
You save per year
$563
Payback
16.0 years
Net after 10 years
-$3,372

Cooling $392Heating $268Electricity used: 4,126 kWhSaved vs. a minimum-efficiency heat pump: $280

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.