HVAC Rated

2-ton central heat pump · NS22H SERIES

GE NS22H24MA4-**A

Excellent cooling efficiency and very good heating efficiency for a 2-ton central heat pump, but not rated for cold climates.

Ranks #5 of 331 2 ton central heat pumps for cooling efficiency, and costs about $617 a year to run in a mixed climate like Atlanta.

SEER2
22.0 Cooling efficiency over a season
Excellent · beats 99%
HSPF2
9.5 Heating efficiency over a season
Very good · beats 70%
EER2
13.5 Cooling efficiency on a 95°F day
Excellent · beats 95%
Heat at 5°F
16,100 BTU/h67% of its 47°F output
Excellent · beats 90%

A good fit if…

  • You want low cooling bills - its SEER2 beats 99% of central heat pumps.
  • It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 29 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications2 ton, R-410A
General
BrandGE
Outdoor unit modelNS22H24MA4-**A
SeriesNS22H SERIES
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceMarch 13, 2023
Last certifiedMay 27, 2026
Cooling
SEER2Seasonal efficiency, higher is better22.0 (range 20.0-22.0)
EER2Efficiency at 95°F outdoors13.0-13.5
Cooling capacity23,800-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.2-9.5
Capacity at 47°F22,400-23,400 BTU/h
Capacity at 17°F14,000-15,000 BTU/h
Capacity at 5°F14,900-16,100 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.88-2.32
ENERGY STAR cold climateNo
Heating output as it gets colder67% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with NCUU24BP4+TDR+TXV at the standard test temperatures, in BTU/h:

Certified matchups29 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
NCUU24BP4+TDR+TXVNF97U070M3B22.013.58.515,500212396436
NCUU24BP4+TDR+TXVNF96U070V3B22.013.58.515,500212396435
NCUC24BT4+TDRNF96U070V3B22.013.58.515,500212396418
NCUC24BT4+TDRNF97U070M3B22.013.58.515,500212396419
NCUC24BT4+TDRNF97X040V3B21.513.58.515,600212396420
NCUC24BT4+TDRNF97X060V3B21.513.58.515,600212396421
NCUU24BP4+TDR+TXVNF97X040V3B21.513.58.515,600212396437
NCUU24BP4+TDR+TXVNF97X060V3B21.513.58.515,600212396438
NAM30V2TA4-21.013.59.516,100212396412
NAM24E1AT-21.013.58.815,500212396450
NCUU30BP4+TDR+TXVNF97U070M3B21.013.08.515,900212396445
NCUU30BP4+TDR+TXVNF97X040V3B21.013.08.516,000212396446
NCUU30BP4+TDR+TXVNF96U070V3B21.013.08.515,900212396444
NCUC30BT4+TDRNF97U070M3B21.013.08.515,900212396427
NCUU24BP4+TDR+TXVNF96U045V3B21.013.58.515,600212396434
NCUC30BT4+TDRNF96U070V3B21.013.08.515,900212396426
NCUC24BT4+TDRNF96U045V3B21.013.58.515,600212396417
NCUC30BT4+TDRNF97X040V3B21.013.08.516,000212396428
NCHC30BT4+TDRNF97X040V3B21.013.58.215,100212396459
NCHC30BT4+TDRNF96U070V3B21.013.58.215,100212396457
NCHC30BT4+TDRNF97U070M3B21.013.58.215,100212396458
NAM24V2AT-20.513.08.815,300212396449
NCUU30BP4+TDR+TXVNF96U045V3B20.513.08.516,000212396443
NCUC30BT4+TDRNF96U045V3B20.513.08.516,000212396425
NCUU30BP4+TDR+TXVNF97X060V3B20.513.08.516,000212396447
NCUC30BT4+TDRNF97X060V3B20.513.08.516,000212396429
NCHC30BT4+TDRNF96U045V3B20.513.58.215,100212396456
NCHC30BT4+TDRNF97X060V3B20.513.58.215,100212396460
NAM30E1AT-20.013.58.814,900212396451
Yearly running cost in 10 large cities$511-$1,507

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the GE NS22H24MA4-**A?
The GE NS22H24MA4-**A is rated at up to 22.0 SEER2 and 13.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 29 certified matchups SEER2 ranges from 20.0-22.0.
Is the GE NS22H24MA4-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
How much does the GE NS22H24MA4-**A cost to run per year?
At its rated efficiency it costs about $511-$1,507 a year in electricity in large U.S. cities, depending on climate and local rates - for example $649 in Phoenix and $1,275 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the GE NS22H24MA4-**A?
ENERGY STAR lists 29 certified combinations for this outdoor unit. The highest-rated ones use NCUU24BP4+TDR+TXV, NCUC24BT4+TDR, NAM30V2TA4.
What refrigerant does the GE NS22H24MA4-**A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $654/yrYou save $563/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump GE NS22H24MA4-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$654
Current system, per year
$1,217
You save per year
$563
Payback
16.0 years
Net after 10 years
-$3,369

Cooling $381Heating $274Electricity used: 4,089 kWhSaved vs. a minimum-efficiency heat pump: $278

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 27, 2026. How we use the data.