2-ton central heat pump · NS22H SERIES
GE NS22H24MA4-**A
Excellent cooling efficiency and very good heating efficiency for a 2-ton central heat pump, but not rated for cold climates.
Ranks #5 of 331 2 ton central heat pumps for cooling efficiency, and costs about $617 a year to run in a mixed climate like Atlanta.
- SEER2
- 22.0 Cooling efficiency over a seasonExcellent · beats 99%
- HSPF2
- 9.5 Heating efficiency over a seasonVery good · beats 70%
- EER2
- 13.5 Cooling efficiency on a 95°F dayExcellent · beats 95%
- Heat at 5°F
- 16,100 BTU/h67% of its 47°F outputExcellent · beats 90%
A good fit if…
- You want low cooling bills - its SEER2 beats 99% of central heat pumps.
- It will heat most of the year - its HSPF2 beats 70% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
- You want a choice of indoor units - 29 certified pairings.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | GE |
| Outdoor unit model | NS22H24MA4-**A |
| Series | NS22H SERIES |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | March 13, 2023 |
| Last certified | May 27, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 22.0 (range 20.0-22.0) |
| EER2Efficiency at 95°F outdoors | 13.0-13.5 |
| Cooling capacity | 23,800-24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.2-9.5 |
| Capacity at 47°F | 22,400-23,400 BTU/h |
| Capacity at 17°F | 14,000-15,000 BTU/h |
| Capacity at 5°F | 14,900-16,100 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.88-2.32 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with NCUU24BP4+TDR+TXV at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| NCUU24BP4+TDR+TXV | NF97U070M3B | 22.0 | 13.5 | 8.5 | 15,500 | 212396436 |
| NCUU24BP4+TDR+TXV | NF96U070V3B | 22.0 | 13.5 | 8.5 | 15,500 | 212396435 |
| NCUC24BT4+TDR | NF96U070V3B | 22.0 | 13.5 | 8.5 | 15,500 | 212396418 |
| NCUC24BT4+TDR | NF97U070M3B | 22.0 | 13.5 | 8.5 | 15,500 | 212396419 |
| NCUC24BT4+TDR | NF97X040V3B | 21.5 | 13.5 | 8.5 | 15,600 | 212396420 |
| NCUC24BT4+TDR | NF97X060V3B | 21.5 | 13.5 | 8.5 | 15,600 | 212396421 |
| NCUU24BP4+TDR+TXV | NF97X040V3B | 21.5 | 13.5 | 8.5 | 15,600 | 212396437 |
| NCUU24BP4+TDR+TXV | NF97X060V3B | 21.5 | 13.5 | 8.5 | 15,600 | 212396438 |
| NAM30V2TA4 | - | 21.0 | 13.5 | 9.5 | 16,100 | 212396412 |
| NAM24E1AT | - | 21.0 | 13.5 | 8.8 | 15,500 | 212396450 |
| NCUU30BP4+TDR+TXV | NF97U070M3B | 21.0 | 13.0 | 8.5 | 15,900 | 212396445 |
| NCUU30BP4+TDR+TXV | NF97X040V3B | 21.0 | 13.0 | 8.5 | 16,000 | 212396446 |
| NCUU30BP4+TDR+TXV | NF96U070V3B | 21.0 | 13.0 | 8.5 | 15,900 | 212396444 |
| NCUC30BT4+TDR | NF97U070M3B | 21.0 | 13.0 | 8.5 | 15,900 | 212396427 |
| NCUU24BP4+TDR+TXV | NF96U045V3B | 21.0 | 13.5 | 8.5 | 15,600 | 212396434 |
| NCUC30BT4+TDR | NF96U070V3B | 21.0 | 13.0 | 8.5 | 15,900 | 212396426 |
| NCUC24BT4+TDR | NF96U045V3B | 21.0 | 13.5 | 8.5 | 15,600 | 212396417 |
| NCUC30BT4+TDR | NF97X040V3B | 21.0 | 13.0 | 8.5 | 16,000 | 212396428 |
| NCHC30BT4+TDR | NF97X040V3B | 21.0 | 13.5 | 8.2 | 15,100 | 212396459 |
| NCHC30BT4+TDR | NF96U070V3B | 21.0 | 13.5 | 8.2 | 15,100 | 212396457 |
| NCHC30BT4+TDR | NF97U070M3B | 21.0 | 13.5 | 8.2 | 15,100 | 212396458 |
| NAM24V2AT | - | 20.5 | 13.0 | 8.8 | 15,300 | 212396449 |
| NCUU30BP4+TDR+TXV | NF96U045V3B | 20.5 | 13.0 | 8.5 | 16,000 | 212396443 |
| NCUC30BT4+TDR | NF96U045V3B | 20.5 | 13.0 | 8.5 | 16,000 | 212396425 |
| NCUU30BP4+TDR+TXV | NF97X060V3B | 20.5 | 13.0 | 8.5 | 16,000 | 212396447 |
| NCUC30BT4+TDR | NF97X060V3B | 20.5 | 13.0 | 8.5 | 16,000 | 212396429 |
| NCHC30BT4+TDR | NF96U045V3B | 20.5 | 13.5 | 8.2 | 15,100 | 212396456 |
| NCHC30BT4+TDR | NF97X060V3B | 20.5 | 13.5 | 8.2 | 15,100 | 212396460 |
| NAM30E1AT | - | 20.0 | 13.5 | 8.8 | 14,900 | 212396451 |
Yearly running cost in 10 large cities
- Phoenix, AZ$649/yr
- Miami, FL$511/yr
- Houston, TX$583/yr
- Atlanta, GA$617/yr
- Los Angeles, CA$606/yr
- New York, NY$1,507/yr
- Chicago, IL$1,230/yr
- Denver, CO$1,028/yr
- Seattle, WA$636/yr
- Minneapolis, MN$1,275/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the GE NS22H24MA4-**A?
- The GE NS22H24MA4-**A is rated at up to 22.0 SEER2 and 13.5 EER2 for cooling and up to 9.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 29 certified matchups SEER2 ranges from 20.0-22.0.
- Is the GE NS22H24MA4-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
- How much does the GE NS22H24MA4-**A cost to run per year?
- At its rated efficiency it costs about $511-$1,507 a year in electricity in large U.S. cities, depending on climate and local rates - for example $649 in Phoenix and $1,275 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the GE NS22H24MA4-**A?
- ENERGY STAR lists 29 certified combinations for this outdoor unit. The highest-rated ones use NCUU24BP4+TDR+TXV, NCUC24BT4+TDR, NAM30V2TA4.
- What refrigerant does the GE NS22H24MA4-**A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Trane 5TWV0X24A1 · cold climate22.4 SEER2 · 10.0 HSPF2
- SAMYOU VUH24-VA6BA(O) · cold climate21.0 SEER2 · 11.0 HSPF2
- Lennox SL25XPV-024-230A · cold climate22.8 SEER2 · 9.2 HSPF2
- Armstrong Air A7CP21V24P-**A · cold climate21.0 SEER2 · 10.2 HSPF2
- Carrier 27VNA324A*030 · cold climate23.0 SEER2 · 10.5 HSPF2
- Lennox EL21KLV-024-230A · cold climate21.0 SEER2 · 10.2 HSPF2
- Arcoaire B5H3V24*K*AAA · cold climate23.0 SEER2 · 10.5 HSPF2
- LG KUSXB241A · cold climate21.0 SEER2 · 10.2 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 27, 2026. How we use the data.