HVAC Rated

2-ton central heat pump · DH9VSA

Daikin DH9VSA241CA

Excellent cooling efficiency and very good heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #10 of 331 2 ton central heat pumps for cooling efficiency, and costs about $583 a year to run in a mixed climate like Atlanta.

SEER2
21.0 Cooling efficiency over a season
Excellent · beats 97%
HSPF2
10.0 Heating efficiency over a season
Very good · beats 84%
EER2
12.2 Cooling efficiency on a 95°F day
Very good · beats 75%
Heat at 5°F
24,000 BTU/h100% of its 47°F output
Excellent · beats 95%

A good fit if…

  • You want low cooling bills - its SEER2 beats 97% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 24,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-32
General
BrandDaikin
Also sold asAmana
Outdoor unit modelDH9VSA241CA
SeriesDH9VSA
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableYes
On the market sinceFebruary 3, 2025
Last certifiedJanuary 20, 2026
Cooling
SEER2Seasonal efficiency, higher is better21.0 (range 16.9-21.0)
EER2Efficiency at 95°F outdoors11.7-12.2
Cooling capacity23,000-24,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-10.0
Capacity at 47°F21,000-24,000 BTU/h
Capacity at 17°F21,000-24,000 BTU/h
Capacity at 5°F21,000-24,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00-2.40
ENERGY STAR cold climateYes
Heating output as it gets colder100% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CAHEA3630C3A*+MBVK16CH*X00A at the standard test temperatures, in BTU/h:

Certified matchups45 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CAHEA3630C3A*+MBVK16CH*X00A · cold climate-21.012.210.024,000216699791
DFVE48CP1300A · cold climate-19.211.79.222,400216699797
DFVE48CP0300A · cold climate-19.211.79.222,400216699798
CA*EA4830*3A*+MBVK16CP1X00A · cold climate-19.211.79.222,000216699800
CA*EA4830*3A · cold climateD*96TC1005CNA*19.211.79.222,000216699802
CA*EA4830*3A · cold climateD*96TC0804CNA*19.211.79.222,000216699804
CA*EA4830*3A · cold climateD*80TC1005C*A*19.211.79.222,000216699806
CA*EA4830*3A · cold climateD*80TC0805C*A*19.211.79.222,000216699808
CA*EA4830*3A · cold climateD*80TC0804C*A*19.211.79.222,000216699810
CA*EA4830*3A · cold climateD*96SC0805CUA*19.211.79.222,000216699812
CA*EA4830*3A · cold climateD*80SC0805CUA*19.211.79.222,000216699814
CA*EA4830*3A · cold climateD*97MC1005CNA*19.211.79.222,000216699816
CA*EA4830*3A · cold climateD*97MC0804CNA*19.211.79.222,000216699818
CA*EA4830*3A*+MBVK16CP0X00A · cold climate-19.211.79.222,000217589468
CA*EA4830*3A · cold climateD*96TC0803BNA*19.211.79.222,000217883054
CA*EA4830*3A · cold climateD*96TC0603BNA*19.211.79.222,000217883056
CA*EA4830*3A · cold climateD*80TC0803B*A*19.211.79.222,000217883058
CA*EA4830*3A · cold climateD*80TC0604B*A*19.211.79.222,000217883060
CA*EA4830*3A · cold climateD*80TC0603B*A*19.211.79.222,000217883062
CA*EA4830*3A · cold climateD*96SC0603BUA*19.211.79.222,000217883064
CA*EA4830*3A · cold climateD*80SC0604BUA*19.211.79.222,000217883066
CA*EA4830*3A · cold climateD*97MC0803BNA*19.211.79.222,000217883068
CA*EA4830*3A · cold climateD*97MC0603BNA*19.211.79.222,000217883070
CA*EA4830*3A · cold climateD*96TC0403BNA*19.211.79.222,000217883103
CHPEA4830*3A*+MBVK16CP1X00A · cold climate-18.211.79.021,000216699799
CHPEA4830*3A · cold climateD*80TC1005C*A*18.211.79.021,000216699805
CHPEA4830*3A · cold climateD*80TC0805C*A*18.211.79.021,000216699807
CHPEA4830*3A · cold climateD*80TC0804C*A*18.211.79.021,000216699809
CHPEA4830*3A · cold climateD*96SC0805CUA*18.211.79.021,000216699811
CHPEA4830*3A · cold climateD*80SC0805CUA*18.211.79.021,000216699813
CHPEA4830*3A · cold climateD*97MC1005CNA*18.211.79.021,000216699815
CHPEA4830*3A · cold climateD*97MC0804CNA*18.211.79.021,000216699817
CHPEA4830*3A*+MBVK16CP0X00A · cold climate-18.211.79.021,000217589467
CHPEA4830*3A · cold climateD*97MC0803BNA*18.211.79.021,000217883069
CHPEA4830*3A · cold climateD*96TC0803BNA*18.211.79.021,000217883053
CHPEA4830*3A · cold climateD*96TC0603BNA*18.211.79.021,000217883055
CHPEA4830*3A · cold climateD*80TC0803B*A*18.211.79.021,000217883057
CHPEA4830*3A · cold climateD*80TC0604B*A*18.211.79.021,000217883059
CHPEA4830*3A · cold climateD*80TC0603B*A*18.211.79.021,000217883061
CHPEA4830*3A · cold climateD*80SC0604BUA*18.211.79.021,000217883065
CHPEA4830*3A · cold climateD*96SC0603BUA*18.211.79.021,000217883063
CHPEA4830*3A · cold climateD*97MC0603BNA*18.211.79.021,000217883067
CHPEA4830*3A · cold climateD*96TC0403BNA*18.211.79.021,000217883071
CHPEA4830*3A · cold climateD*96TC1005CNA*18.211.78.521,000216699801
CHPEA4830*3A · cold climateD*96TC0804CNA*16.911.79.021,000216699803
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Daikin DH9VSA241CA: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$523-$1,392

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Daikin DH9VSA241CA?
The Daikin DH9VSA241CA is rated at up to 21.0 SEER2 and 12.2 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 45 certified matchups SEER2 ranges from 16.9-21.0.
Is the Daikin DH9VSA241CA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 24,000 BTU/h at 5°F with a COP of 2.40, so it is still 2.4 times as efficient as electric resistance heat at that temperature.
How much does the Daikin DH9VSA241CA cost to run per year?
At its rated efficiency it costs about $523-$1,392 a year in electricity in large U.S. cities, depending on climate and local rates - for example $644 in Phoenix and $1,162 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Daikin DH9VSA241CA the same as the Amana AZV9SA241CA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Daikin DH9VSA241CA?
ENERGY STAR lists 45 certified combinations for this outdoor unit. The highest-rated ones use CAHEA3630C3A*+MBVK16CH*X00A, DFVE48CP1300A, DFVE48CP0300A.
What refrigerant does the Daikin DH9VSA241CA use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $639/yrYou save $545/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Daikin DH9VSA241CA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$639
Current system, per year
$1,184
You save per year
$545
Payback
16.5 years
Net after 10 years
-$3,550

Cooling $392Heating $246Electricity used: 3,991 kWhSaved vs. a minimum-efficiency heat pump: $266

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of January 20, 2026. How we use the data.