2-ton central heat pump · 4SHP22LX SERIES
Armstrong Air 4SHP22LX124P-**A
Excellent cooling efficiency and average heating efficiency for a 2-ton central heat pump, but not rated for cold climates.
Ranks #17 of 331 2 ton central heat pumps for cooling efficiency, and costs about $625 a year to run in a mixed climate like Atlanta.
- SEER2
- 21.0 Cooling efficiency over a seasonExcellent · beats 97%
- HSPF2
- 9.0 Heating efficiency over a seasonAverage · beats 54%
- EER2
- 13.5 Cooling efficiency on a 95°F dayExcellent · beats 95%
- Heat at 5°F
- 16,100 BTU/h72% of its 47°F outputExcellent · beats 90%
A good fit if…
- You want low cooling bills - its SEER2 beats 97% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- You often see nights below 0°F - it is not cold-climate certified.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | Armstrong Air |
| Also sold as | AIREASE |
| Outdoor unit model | 4SHP22LX124P-**A |
| Series | 4SHP22LX SERIES |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | March 13, 2023 |
| Last certified | May 27, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 21.0 (range 17.5-21.0) |
| EER2Efficiency at 95°F outdoors | 13.0-13.5 |
| Cooling capacity | 22,800-24,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.8-9.0 |
| Capacity at 47°F | 21,000-22,400 BTU/h |
| Capacity at 17°F | 14,100-14,300 BTU/h |
| Capacity at 5°F | 14,900-16,100 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 2.14-2.32 |
| ENERGY STAR cold climate | No |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with BCE7S30M*4X at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| BCE7S30M*4X | 21.0 | 13.5 | 9.0 | 16,100 | 211729602 |
| BCE7S30M*4X | 21.0 | 13.5 | 9.0 | 16,100 | 211729601 |
| BCE5E30M | 20.0 | 13.5 | 8.8 | 14,900 | 211729606 |
| BCE5E30M | 20.0 | 13.5 | 8.8 | 14,900 | 211729604 |
| BCE5E24M | 17.5 | 13.0 | 8.8 | 15,500 | 211729605 |
| BCE5E24M | 17.5 | 13.0 | 8.8 | 15,500 | 211729603 |
Yearly running cost in 10 large cities
- Phoenix, AZ$667/yr
- Miami, FL$530/yr
- Houston, TX$599/yr
- Atlanta, GA$625/yr
- Los Angeles, CA$613/yr
- New York, NY$1,519/yr
- Chicago, IL$1,238/yr
- Denver, CO$1,033/yr
- Seattle, WA$638/yr
- Minneapolis, MN$1,280/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Armstrong Air 4SHP22LX124P-**A?
- The Armstrong Air 4SHP22LX124P-**A is rated at up to 21.0 SEER2 and 13.5 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 6 certified matchups SEER2 ranges from 17.5-21.0.
- Is the Armstrong Air 4SHP22LX124P-**A good for cold climates?
- It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 2-ton model.
- How much does the Armstrong Air 4SHP22LX124P-**A cost to run per year?
- At its rated efficiency it costs about $530-$1,519 a year in electricity in large U.S. cities, depending on climate and local rates - for example $667 in Phoenix and $1,280 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Armstrong Air 4SHP22LX124P-**A?
- ENERGY STAR lists 6 certified combinations for this outdoor unit. The highest-rated ones use BCE7S30M*4X, BCE5E30M, BCE5E24M.
- What refrigerant does the Armstrong Air 4SHP22LX124P-**A use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- RUSSELL SP19AY24AJVC · cold climate21.0 SEER2 · 9.5 HSPF2
- Lennox SL22KLV-024-230A · cold climate20.5 SEER2 · 10.5 HSPF2
- Mainline MLP19AY24AJVC · cold climate21.0 SEER2 · 9.5 HSPF2
- GE NS21H24MA5-**A · cold climate20.5 SEER2 · 10.2 HSPF2
- Ruud UP19AY24AJVC · cold climate21.0 SEER2 · 10.0 HSPF2
- MDV MOX430-24HFN8-M3 · cold climate20.0 SEER2 · 10.4 HSPF2
- Rheem RP19AY24AJVC · cold climate21.0 SEER2 · 10.0 HSPF2
- Trane 5TCV0X36A1 · cold climate20.0 SEER2 · 10.3 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 27, 2026. How we use the data.