HVAC Rated

2-ton central heat pump · DH7VSA

Daikin DH7VSA2410A

Very good cooling efficiency and average heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #58 of 331 2 ton central heat pumps for cooling efficiency, and costs about $676 a year to run in a mixed climate like Atlanta.

SEER2
19.0 Cooling efficiency over a season
Very good · beats 85%
HSPF2
8.8 Heating efficiency over a season
Average · beats 49%
EER2
11.0 Cooling efficiency on a 95°F day
Below average · beats 23%
Heat at 5°F
17,000 BTU/h73% of its 47°F output
Below average · beats 39%

A good fit if…

  • You want low cooling bills - its SEER2 beats 85% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 17,000 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 90 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-32
General
BrandDaikin
Outdoor unit modelDH7VSA2410A
SeriesDH7VSA
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-32
Connected (smart) capableYes
On the market sinceJuly 10, 2025
Last certifiedJuly 28, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.0 (range 16.0-19.0)
EER2Efficiency at 95°F outdoors10.5-11.0
Cooling capacity23,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-8.8
Capacity at 47°F23,200 BTU/h
Capacity at 17°F15,800 BTU/h
Capacity at 5°F17,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.00
ENERGY STAR cold climateYes
Heating output as it gets colder73% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with DFVE36CP1300A at the standard test temperatures, in BTU/h:

Certified matchups90 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 90 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
DFVE36CP1300A · cold climate-19.011.08.817,000215415508
DFVE36CP0300A · cold climate-19.011.08.817,000215429723
CA*EA3022*3A*+MBVK16CP1X00A · cold climate-19.011.08.617,000215433894
CA*EA3022*3A*+MBVK12BP1X00A · cold climate-19.011.08.617,000215433893
CA*EA3626*3A*+MBVK12BP1X00A · cold climate-19.011.08.617,000215433895
CA*EA3626*3A*+MBVK16CP1X00A · cold climate-19.011.08.617,000215433896
CHPEA3026*3A*+MBVK12BP1X00A · cold climate-19.011.08.617,000215433897
CHPEA3026*3A*+MBVK16CP1X00A · cold climate-19.011.08.617,000215433898
CA*EA3022*3A · cold climateD*97MC0603BNA*19.011.08.617,000215433967
CA*EA3022*3A · cold climateD*97MC0804CNA*19.011.08.617,000215433969
CA*EA3022*3A · cold climateD*97MC0803BNA*19.011.08.617,000215433968
CA*EA3022*3A · cold climateD*97MC1005CNA*19.011.08.617,000215433970
CA*EA3022*3A · cold climateD*80SC0604BUA*19.011.08.617,000215433971
CA*EA3022*3A · cold climateD*80SC0805CUA*19.011.08.617,000215433972
CA*EA3022*3A · cold climateD*96SC0603BUA*19.011.08.617,000215433973
CA*EA3022*3A · cold climateD*96SC0805CUA*19.011.08.617,000215433974
CA*EA3022*3A · cold climateD*80TC0603B*A*19.011.08.617,000215433975
CA*EA3022*3A · cold climateD*80TC0803B*A*19.011.08.617,000215433976
CA*EA3022*3A · cold climateD*80TC0804C*A*19.011.08.617,000215433977
CA*EA3022*3A · cold climateD*80TC0805C*A*19.011.08.617,000215433978
CA*EA3022*3A · cold climateD*80TC1005C*A*19.011.08.617,000215433979
CA*EA3022*3A · cold climateD*96TC0403BNA*19.011.08.617,000215433980
CA*EA3022*3A · cold climateD*96TC0603BNA*19.011.08.617,000215433981
CA*EA3022*3A · cold climateD*96TC0803BNA*19.011.08.617,000215433982
CA*EA3022*3A · cold climateD*96TC0804CNA*19.011.08.617,000215433983
CA*EA3022*3A · cold climateD*96TC1005CNA*19.011.08.617,000215433984
CA*EA3626*3A · cold climateD*97MC0603BNA*19.011.08.617,000215433985
CA*EA3626*3A · cold climateD*97MC0803BNA*19.011.08.617,000215433986
CA*EA3626*3A · cold climateD*97MC0804CNA*19.011.08.617,000215433987
CA*EA3626*3A · cold climateD*80SC0604BUA*19.011.08.617,000215433989
CA*EA3626*3A · cold climateD*97MC1005CNA*19.011.08.617,000215433988
CA*EA3626*3A · cold climateD*80SC0805CUA*19.011.08.617,000215433990
CA*EA3626*3A · cold climateD*96SC0603BUA*19.011.08.617,000215433991
CA*EA3626*3A · cold climateD*80TC0603B*A*19.011.08.617,000215433993
CA*EA3626*3A · cold climateD*96SC0805CUA*19.011.08.617,000215433992
CA*EA3626*3A · cold climateD*80TC0604B*A*19.011.08.617,000215433994
CA*EA3626*3A · cold climateD*80TC0803B*A*19.011.08.617,000215433995
CA*EA3626*3A · cold climateD*80TC0804C*A*19.011.08.617,000215433996
CA*EA3626*3A · cold climateD*80TC0805C*A*19.011.08.617,000215433997
CA*EA3626*3A · cold climateD*80TC1005C*A*19.011.08.617,000215433998
CA*EA3626*3A · cold climateD*96TC0403BNA*19.011.08.617,000215433999
CA*EA3626*3A · cold climateD*96TC0603BNA*19.011.08.617,000215434000
CA*EA3626*3A · cold climateD*96TC0803BNA*19.011.08.617,000215434001
CA*EA3626*3A · cold climateD*96TC0804CNA*19.011.08.617,000215434002
CA*EA3626*3A · cold climateD*96TC1005CNA*19.011.08.617,000215434003
CHPEA3026*3A · cold climateD*97MC0603BNA*19.011.08.617,000215434004
CHPEA3026*3A · cold climateD*97MC0803BNA*19.011.08.617,000215434005
CHPEA3026*3A · cold climateD*97MC0804CNA*19.011.08.617,000215434006
CHPEA3026*3A · cold climateD*97MC1005CNA*19.011.08.617,000215434007
CHPEA3026*3A · cold climateD*80SC0604BUA*19.011.08.617,000215434008
CHPEA3026*3A · cold climateD*80SC0805CUA*19.011.08.617,000215434009
CHPEA3026*3A · cold climateD*96SC0603BUA*19.011.08.617,000215434010
CHPEA3026*3A · cold climateD*96SC0805CUA*19.011.08.617,000215434011
CHPEA3026*3A · cold climateD*80TC0603B*A*19.011.08.617,000215434012
CHPEA3026*3A · cold climateD*80TC0604B*A*19.011.08.617,000215434013
CHPEA3026*3A · cold climateD*80TC0803B*A*19.011.08.617,000215434014
CHPEA3026*3A · cold climateD*80TC0804C*A*19.011.08.617,000215434015
CHPEA3026*3A · cold climateD*80TC1005C*A*19.011.08.617,000215434017
CHPEA3026*3A · cold climateD*80TC0805C*A*19.011.08.617,000215434016
CHPEA3026*3A · cold climateD*96TC0403BNA*19.011.08.617,000215434018
Yearly running cost in 10 large cities$575-$1,640

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Daikin DH7VSA2410A?
The Daikin DH7VSA2410A is rated at up to 19.0 SEER2 and 11.0 EER2 for cooling and up to 8.8 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 90 certified matchups SEER2 ranges from 16.0-19.0.
Is the Daikin DH7VSA2410A good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 17,000 BTU/h at 5°F with a COP of 2.00, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Daikin DH7VSA2410A cost to run per year?
At its rated efficiency it costs about $575-$1,640 a year in electricity in large U.S. cities, depending on climate and local rates - for example $723 in Phoenix and $1,381 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Daikin DH7VSA2410A?
ENERGY STAR lists 90 certified combinations for this outdoor unit. The highest-rated ones use DFVE36CP1300A, DFVE36CP0300A, CA*EA3022*3A*+MBVK16CP1X00A.
What refrigerant does the Daikin DH7VSA2410A use?
It uses R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $725/yrYou save $471/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Daikin DH7VSA2410A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$725
Current system, per year
$1,196
You save per year
$471
Payback
18.0 years
Net after 10 years
-$3,788

Cooling $430Heating $295Electricity used: 4,532 kWhSaved vs. a minimum-efficiency heat pump: $192

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 28, 2026. How we use the data.