HVAC Rated

2-ton central heat pump · Deluxe 20 VS Heat Pump

Kenmore B5H0V24*K*AAA

Very good cooling efficiency and average heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #57 of 331 2 ton central heat pumps for cooling efficiency, and costs about $690 a year to run in a mixed climate like Atlanta.

SEER2
19.0 Cooling efficiency over a season
Very good · beats 85%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
11.0 Cooling efficiency on a 95°F day
Below average · beats 23%
Heat at 5°F
17,300 BTU/h58% of its 47°F output
Average · beats 48%

A good fit if…

  • You want low cooling bills - its SEER2 beats 85% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 17,300 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 284 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandKenmore
Also sold asACIQ, Keeprite, Day & Night, Comfortmaker, Tempstar, Arcoaire, Airquest, Heil
Outdoor unit modelB5H0V24*K*AAA
SeriesDeluxe 20 VS Heat Pump
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJune 12, 2023
Last certifiedSeptember 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better19.0 (range 15.5-19.0)
EER2Efficiency at 95°F outdoors9.0-11.0
Cooling capacity22,400-24,400 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-9.0
Capacity at 47°F23,200-27,800 BTU/h
Capacity at 17°F19,400-20,800 BTU/h
Capacity at 5°F16,100-17,300 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.82-2.04
ENERGY STAR cold climateYes
Heating output as it gets colder58% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EVD5X31M17A*+WALLCON at the standard test temperatures, in BTU/h:

Certified matchups284 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 284 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EVD5X31M17A*+WALLCON*80CTL0901716B*19.011.08.516,100218169781
EVD5X31M17A*+WALLCON*80CTL0701412B*19.011.08.516,200218169775
EVD5X31M17A*+WALLCON*80CTL0701412B*19.011.08.516,200218169774
EVD5X31M17A*+WALLCON*80CTL0701412B*19.011.08.516,200218169773
EVD5X31M17A*+WALLCON*80CTL0901716B*19.011.08.516,100218164261
EVD5X31M17A*+WALLCON*80CTL0701412B*19.011.08.516,200218164259
EVD5X31M17A*+WALLCON*80CTL0701412B*19.011.08.516,200218161000
EVD5X31M17A*+WALLCON*80CTL0701412B*19.011.08.516,200218160999
EVD5X31M17A*+WALLCON*80CTL0701412B*19.011.08.516,200218160998
EVD5X38M17A*+WALLCON*96CTN0801714B*19.011.08.516,200218169931
EVD5X38M17A*+WALLCON*96CTN0801714B*19.011.08.516,200218169930
EVD5X38M17A*+WALLCON*96CTN0801714B*19.011.08.516,200218169929
EVD5X38M17A*+WALLCON*97CMN0801714B*19.011.08.516,200218169922
EVD5X38M17A*+WALLCON*97CMN0801714B*19.011.08.516,200218169921
EVD5X38M17A*+WALLCON*97CMN0801714B*19.011.08.516,200218169920
EVD5X38M17A*+WALLCON*80CTL0901716B*19.011.08.516,200218169916
EVD5X38M17A*+WALLCON*80CTL0901716B*19.011.08.516,200218169915
EVD5X38M17A*+WALLCON*80CTL0901716B*19.011.08.516,200218169914
EVD5X38M17A*+WALLCON*80CTL0701716B*19.011.08.516,200218169913
EVD5X38M17A*+WALLCON*80CTL0701716B*19.011.08.516,200218169912
EVD5X38M17A*+WALLCON*80CTL0701716B*19.011.08.516,200218169911
EVD5X31M17A*+WALLCON*80CTL0901716B*19.011.08.516,100218169780
EVD5X31M17A*+WALLCON*80CTL0901716B*19.011.08.516,100218169779
EVM5X32M17A*+WALLCON*96CTN0801714B*19.011.08.516,200218169646
EVM5X32M17A*+WALLCON*96CTN0801714B*19.011.08.516,200218169645
EVM5X32M17A*+WALLCON*96CTN0801714B*19.011.08.516,200218169644
EVM5X32M17A*+WALLCON*80CTL0901716B*19.011.08.516,200218169631
EVM5X32M17A*+WALLCON*80CTL0901716B*19.011.08.516,200218169630
EVM5X32M17A*+WALLCON*80CTL0901716B*19.011.08.516,200218169629
EVM5X32M17A*+WALLCON*80CTL0701716B*19.011.08.516,200218169628
EVM5X32M17A*+WALLCON*80CTL0701716B*19.011.08.516,200218169627
EVM5X32M17A*+WALLCON*80CTL0701716B*19.011.08.516,200218169626
EVM5X31M17A*+WALLCON*80CTL0901716B*19.011.08.516,200218169607
EVM5X31M17A*+WALLCON*80CTL0901716B*19.011.08.516,200218169606
EVM5X31M17A*+WALLCON*80CTL0901716B*19.011.08.516,200218169605
EVM5X31M17A*+WALLCON*80CTL0701412B*19.011.08.516,200218169601
EVM5X31M17A*+WALLCON*80CTL0701412B*19.011.08.516,200218169600
EVM5X31M17A*+WALLCON*80CTL0701412B*19.011.08.516,200218169599
EVD5X38M17A*+WALLCON*96CTN0801714B*19.011.08.516,200218164311
EVD5X38M17A*+WALLCON*97CMN0801714B*19.011.08.516,200218164308
EVD5X38M17A*+WALLCON*80CTL0901716B*19.011.08.516,200218164306
EVD5X38M17A*+WALLCON*80CTL0701716B*19.011.08.516,200218164305
EVM5X32M17A*+WALLCON*96CTN0801714B*19.011.08.516,200218164216
EVM5X32M17A*+WALLCON*80CTL0901716B*19.011.08.516,200218164211
EVM5X32M17A*+WALLCON*80CTL0701716B*19.011.08.516,200218164210
EVM5X31M17A*+WALLCON*80CTL0901716B*19.011.08.516,200218164203
EVM5X31M17A*+WALLCON*80CTL0701412B*19.011.08.516,200218164201
EVD5X38M17A*+WALLCON*96CTN0801714B*19.011.08.516,200218161154
EVD5X38M17A*+WALLCON*96CTN0801714B*19.011.08.516,200218161153
EVD5X38M17A*+WALLCON*96CTN0801714B*19.011.08.516,200218161152
EVD5X38M17A*+WALLCON*97CMN0801714B*19.011.08.516,200218161145
EVD5X38M17A*+WALLCON*97CMN0801714B*19.011.08.516,200218161144
EVD5X38M17A*+WALLCON*97CMN0801714B*19.011.08.516,200218161143
EVD5X38M17A*+WALLCON*80CTL0901716B*19.011.08.516,200218161139
EVD5X38M17A*+WALLCON*80CTL0901716B*19.011.08.516,200218161138
EVD5X38M17A*+WALLCON*80CTL0901716B*19.011.08.516,200218161137
EVD5X38M17A*+WALLCON*80CTL0701716B*19.011.08.516,200218161136
EVD5X38M17A*+WALLCON*80CTL0701716B*19.011.08.516,200218161135
EVD5X38M17A*+WALLCON*80CTL0701716B*19.011.08.516,200218161134
EVD5X31M17A*+WALLCON*80CTL0901716B*19.011.08.516,100218161006
Yearly running cost in 10 large cities$595-$1,666

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Kenmore B5H0V24*K*AAA?
The Kenmore B5H0V24*K*AAA is rated at up to 19.0 SEER2 and 11.0 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 284 certified matchups SEER2 ranges from 15.5-19.0.
Is the Kenmore B5H0V24*K*AAA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 17,300 BTU/h at 5°F with a COP of 2.04, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Kenmore B5H0V24*K*AAA cost to run per year?
At its rated efficiency it costs about $595-$1,666 a year in electricity in large U.S. cities, depending on climate and local rates - for example $744 in Phoenix and $1,400 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Kenmore B5H0V24*K*AAA?
ENERGY STAR lists 284 certified combinations for this outdoor unit. The highest-rated ones use EVD5X31M17A*+WALLCON, EVD5X38M17A*+WALLCON, EVM5X32M17A*+WALLCON.
What refrigerant does the Kenmore B5H0V24*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $743/yrYou save $494/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Kenmore B5H0V24*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$743
Current system, per year
$1,238
You save per year
$494
Payback
18.2 years
Net after 10 years
-$4,058

Cooling $445Heating $299Electricity used: 4,646 kWhSaved vs. a minimum-efficiency heat pump: $206

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 16, 2026. How we use the data.