HVAC Rated

2-ton central heat pump · Infinity 23 VS Heat Pump

Carrier 27VNA324A*030

Excellent cooling and heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #2 of 331 2 ton central heat pumps for cooling efficiency, and costs about $628 a year to run in a mixed climate like Atlanta.

SEER2
23.0 Cooling efficiency over a season
Excellent · beats 99%
HSPF2
10.5 Heating efficiency over a season
Excellent · beats 96%
EER2
14.0 Cooling efficiency on a 95°F day
Excellent · beats 98%
Heat at 5°F
23,000 BTU/h81% of its 47°F output
Average · beats 58%

A good fit if…

  • You want low cooling bills - its SEER2 beats 99% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 23,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 96% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandCarrier
Also sold asBryant
Outdoor unit model27VNA324A*030
SeriesInfinity 23 VS Heat Pump
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceAugust 8, 2025
Last certifiedMay 1, 2026
Cooling
SEER2Seasonal efficiency, higher is better23.0 (range 18.0-23.0)
EER2Efficiency at 95°F outdoors10.5-14.0
Cooling capacity21,600-23,800 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-10.5
Capacity at 47°F24,800-28,200 BTU/h
Capacity at 17°F24,000-26,400 BTU/h
Capacity at 5°F19,100-23,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.84-2.10
ENERGY STAR cold climateYes
Heating output as it gets colder81% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CVAMA4421XMA*+UI at the standard test temperatures, in BTU/h:

Certified matchups430 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 430 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CVAMA4421XMA*+UI · cold climate58CU*B040C17**1223.014.09.522,400217624611
CVAMA3217XMA*+UI · cold climate58CU*B060C17**1623.013.59.522,400217624639
CVAVA3817XMA*+UI · cold climate58CU*B060C17**1623.013.59.522,400217624663
CVAMA4421XMA*+UI · cold climate58TN*B090C17**1623.013.59.522,400217624795
CVAMA4321XMA*+UI · cold climate58CU*B040C17**1222.513.59.522,200217624609
CVAMA3117XMA*+UI · cold climate58CU*B040C17**1222.513.59.522,400217624603
CVAMA3217XMA*+UI · cold climate59TN6C060C17**1422.513.09.522,600217624969
CVAMA4421XMA*+UI · cold climate59TN6C060C17**1422.513.59.522,400217624977
CVAVA3817XMA*+UI · cold climate59TN6C060C17**1422.513.09.522,600217624993
CVAMA3217XMA*+UI · cold climate59TN6C080C17**1422.513.59.522,400217625007
CVAMA4421XMA*+UI · cold climate59TN6C080C17**1422.513.59.522,400217625013
CVAVA3817XMA*+UI · cold climate59TN6C080C17**1422.513.59.522,400217625029
CVAMA4421XMA*+UI · cold climate59TN7A080C17**1622.513.59.522,400217625089
CVAVA3817XMA*+UI · cold climate59TN7A080C17**1622.513.09.522,400217625105
CVAVA3117XMA*+UI · cold climate58CU*B040C17**1222.513.59.522,400217624619
CVAVA3817XMA*+UI · cold climate58CU*B040C17**1222.513.59.522,400217624627
CVAMA3117XMA*+UI · cold climate58CU*B060C17**1622.513.59.522,400217624637
CVAMA4321XMA*+UI · cold climate58CU*B060C17**1622.513.59.522,200217624645
CVAMA4421XMA*+UI · cold climate58CU*B060C17**1622.514.09.522,400217624647
CVAVA3117XMA*+UI · cold climate58CU*B060C17**1622.513.59.522,400217624655
CVAVA3721XMA*+UI · cold climate58CU*B060C17**1622.513.59.522,200217624661
CVAMA3117XMA*+UI · cold climate58TN*B070C14**1222.513.09.522,400217624715
CVAMA3217XMA*+UI · cold climate58TN*B070C14**1222.513.59.522,400217624717
CVAVA3117XMA*+UI · cold climate58TN*B070C14**1222.513.59.522,400217624733
CVAVA3817XMA*+UI · cold climate58TN*B070C14**1222.513.59.522,400217624737
CVAMA3217XMA*+UI · cold climate58TN*B070C17**1622.513.59.522,400217624749
CVAMA4421XMA*+UI · cold climate58TN*B070C17**1622.513.59.522,400217624757
CVAMA3117XMA*+UI · cold climate58TN*B090C17**1622.513.59.522,400217624785
CVAMA3217XMA*+UI · cold climate58TN*B090C17**1622.513.59.522,400217624787
CVAVA3117XMA*+UI · cold climate58TN*B090C17**1622.513.59.522,400217624803
CVAVA3817XMA*+UI · cold climate58TN*B090C17**1622.513.59.522,400217624811
CVAMA4421XMA*+UI · cold climate59CU5B060C17**1622.513.59.522,400217624831
CVAMA3217XMA*+UI · cold climate59MN7C080C17**1422.513.09.522,400217624899
CVAVA3817XMA*+UI · cold climate59MN7C080C17**1422.513.59.522,400217624921
CVAMA4221XMA*+UI · cold climate58CU*B040C17**1222.013.59.522,200217624607
CVAMA2517XMA*+UI · cold climate58CU*B040C17**1222.013.09.522,200217624599
CVAMA3017XMA*+UI · cold climate58CU*B040C17**1222.013.09.522,200217624601
CVAMA3617XMA*+UI · cold climate58CU*B040C17**1222.013.09.522,200217624605
CVAVA3117XMA*+UI · cold climate59CU5B060C17**1622.013.09.522,400217624839
CVAMA3117XMA*+UI · cold climate59TN6C060C17**1422.013.09.522,600217624967
CVAVA3817XMA*+UI · cold climate59CU5B060C17**1622.013.59.522,400217624847
CVAMA4321XMA*+UI · cold climate59TN6C060C17**1422.013.09.522,400217624975
CVAVA3117XMA*+UI · cold climate59TN6C060C17**1422.013.09.522,400217624985
CVAVA3721XMA*+UI · cold climate59TN6C060C17**1422.013.09.522,400217624991
CVAMA3117XMA*+UI · cold climate59TN6C080C17**1422.013.09.522,400217625005
CVAMA4321XMA*+UI · cold climate59TN6C080C17**1422.013.09.522,400217625011
CVAVA3117XMA*+UI · cold climate59TN6C080C17**1422.013.59.522,400217625021
CVAVA3721XMA*+UI · cold climate59TN6C080C17**1422.013.09.522,400217625027
CVAMA4421XMA*+UI · cold climate59TN7A060C17**1622.013.09.522,600217625051
CVAMA3117XMA*+UI · cold climate59TN7A080C17**1622.013.09.522,400217625079
CVAMA3217XMA*+UI · cold climate59TN7A080C17**1622.013.09.522,600217625081
CVAVA3117XMA*+UI · cold climate59TN7A080C17**1622.013.09.522,400217625097
CVAMA3117XMA*+UI · cold climate59MN7C060C17**1422.013.09.522,600217624859
CVAMA3217XMA*+UI · cold climate59MN7C060C17**1422.013.09.522,600217624861
CVAMA4421XMA*+UI · cold climate59MN7C060C17**1422.013.09.522,600217624869
CVAVA3117XMA*+UI · cold climate59MN7C060C17**1422.013.09.522,600217624877
CVAVA3817XMA*+UI · cold climate59MN7C060C17**1422.013.09.522,600217624885
CVAVA2517XMA*+UI · cold climate58CU*B040C17**1222.013.09.522,200217624615
CVAVA3017XMA*+UI · cold climate58CU*B040C17**1222.013.09.522,200217624617
CVAVA3617XMA*+UI · cold climate58CU*B040C17**1222.013.09.522,200217624621
Same unit, other model numbers1

These model numbers have exactly the same certified ratings and matchups as the Carrier 27VNA324A*030: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$475-$1,573

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Carrier 27VNA324A*030?
The Carrier 27VNA324A*030 is rated at up to 23.0 SEER2 and 14.0 EER2 for cooling and up to 10.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 430 certified matchups SEER2 ranges from 18.0-23.0.
Is the Carrier 27VNA324A*030 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 23,000 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the Carrier 27VNA324A*030 cost to run per year?
At its rated efficiency it costs about $475-$1,573 a year in electricity in large U.S. cities, depending on climate and local rates - for example $627 in Phoenix and $1,347 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Carrier 27VNA324A*030 the same as the Bryant 293VAN024**AA?
Yes, as far as the certified ratings go. ENERGY STAR lists both model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Carrier 27VNA324A*030?
ENERGY STAR lists 430 certified combinations for this outdoor unit. The highest-rated ones use CVAMA4421XMA*+UI, CVAMA3217XMA*+UI, CVAVA3817XMA*+UI.
What refrigerant does the Carrier 27VNA324A*030 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $644/yrYou save $614/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Carrier 27VNA324A*030
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$644
Current system, per year
$1,258
You save per year
$614
Payback
13.9 years
Net after 10 years
-$2,363

Cooling $352Heating $292Electricity used: 4,027 kWhSaved vs. a minimum-efficiency heat pump: $331

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 1, 2026. How we use the data.