2-ton central heat pump · Performance 19 SEER2 VS HP
Carrier 27VPA924A*030
Excellent cooling efficiency and very good heating efficiency for a 2-ton central heat pump, and certified for cold climates.
Ranks #41 of 331 2 ton central heat pumps for cooling efficiency, and costs about $654 a year to run in a mixed climate like Atlanta.
- SEER2
- 19.5 Cooling efficiency over a seasonExcellent · beats 91%
- HSPF2
- 10.0 Heating efficiency over a seasonVery good · beats 84%
- EER2
- 14.0 Cooling efficiency on a 95°F dayExcellent · beats 98%
- Heat at 5°F
- 22,200 BTU/h95% of its 47°F outputAverage · beats 47%
A good fit if…
- You want low cooling bills - its SEER2 beats 91% of central heat pumps.
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 22,200 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 84% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Nothing stands out - its ratings have no weak spot for its class.
Details
Specifications
| General | |
|---|---|
| Brand | Carrier |
| Outdoor unit model | 27VPA924A*030 |
| Series | Performance 19 SEER2 VS HP |
| Type | Central heat pump |
| Nominal size | 2 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-454B |
| Connected (smart) capable | No |
| On the market since | October 15, 2025 |
| Last certified | September 30, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 19.5 (range 15.2-19.5) |
| EER2Efficiency at 95°F outdoors | 11.5-14.0 |
| Cooling capacity | 22,200-25,400 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 8.0-10.0 |
| Capacity at 47°F | 22,400-25,800 BTU/h |
| Capacity at 17°F | 19,800-25,200 BTU/h |
| Capacity at 5°F | 20,000-22,200 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.74-2.02 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with FT5BD3617X at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 1,222 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | Furnace | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|---|
| FT5BD3617X · cold climate | - | 19.5 | 14.0 | 8.6 | 21,200 | 218695489 |
| CAA**3721AM · cold climate | 58SU*B060M17**16 | 19.0 | 14.0 | 10.0 | 21,000 | 217935038 |
| CAA**3721AM · cold climate | 59TP6C100V21**22 | 19.0 | 14.0 | 10.0 | 21,000 | 217934633 |
| CAA**3721AM · cold climate | 59TP7A100V21**22 | 19.0 | 14.0 | 10.0 | 21,000 | 217934634 |
| CAA**3721AM · cold climate | 58SU*B080M21**20 | 19.0 | 14.0 | 10.0 | 21,000 | 217934939 |
| CAA**3721AM · cold climate | 58SP*B110V21**22 | 19.0 | 14.0 | 10.0 | 21,200 | 217934590 |
| FT5BD2417X · cold climate | - | 19.0 | 13.5 | 8.6 | 20,800 | 218695473 |
| CVAMA3217XMA · cold climate | 59TN6C060C17**14 | 19.0 | 14.0 | 8.5 | 21,400 | 217934126 |
| CVAMA3217XMA · cold climate | 59TN6C080C17**14 | 19.0 | 14.0 | 8.5 | 21,400 | 217934127 |
| CVAMA3217XMA · cold climate | 59TN7A060C17**16 | 19.0 | 14.0 | 8.5 | 21,600 | 217934128 |
| CVAMA3217XMA · cold climate | 59TN7A080C17**16 | 19.0 | 14.0 | 8.5 | 21,400 | 217934129 |
| CVAMA3217XMA · cold climate | 59TP6C060V14**12 | 19.0 | 14.0 | 8.5 | 21,400 | 217934132 |
| CVAMA3217XMA · cold climate | 59TP6C060V17**16 | 19.0 | 14.0 | 8.5 | 21,600 | 217934133 |
| CVAMA3217XMA · cold climate | 59TP6C080V17**16 | 19.0 | 14.0 | 8.5 | 21,600 | 217934134 |
| CVAMA3217XMA · cold climate | 59TP7A060V17**16 | 19.0 | 14.0 | 8.5 | 21,600 | 217934135 |
| CVAMA3217XMA · cold climate | 59TP7A080V17**16 | 19.0 | 14.0 | 8.5 | 21,600 | 217934136 |
| CVAMA3217XMA · cold climate | OVLAAB036098 | 19.0 | 13.5 | 8.5 | 21,800 | 217934137 |
| CVAMA3217XMA · cold climate | OVMAAB036098 | 19.0 | 13.5 | 8.5 | 22,000 | 217934138 |
| CVAMA3217XMA · cold climate | OVMAAB042112 | 19.0 | 14.0 | 8.5 | 21,800 | 217934139 |
| CVAMA3617XMA · cold climate | 58CU*B040C17**12 | 19.0 | 13.5 | 8.5 | 21,400 | 217934140 |
| CVAMA3617XMA · cold climate | 58CU*B060C17**16 | 19.0 | 13.5 | 8.5 | 21,600 | 217934141 |
| CVAMA3617XMA · cold climate | 58SP*B045V14**12 | 19.0 | 13.5 | 8.5 | 21,400 | 217934142 |
| CVAMA3617XMA · cold climate | 58SP*B070V14**12 | 19.0 | 13.5 | 8.5 | 21,400 | 217934143 |
| CVAMA3617XMA · cold climate | 58SP*B070V17**16 | 19.0 | 13.5 | 8.5 | 21,600 | 217934144 |
| CVAMA3617XMA · cold climate | 58SP*B090V17**16 | 19.0 | 13.5 | 8.5 | 21,400 | 217934145 |
| CVAMA3617XMA · cold climate | 58SU*B040M17**12 | 19.0 | 13.5 | 8.5 | 21,400 | 217934146 |
| CVAMA3617XMA · cold climate | 58SU*B060M17**16 | 19.0 | 14.0 | 8.5 | 21,400 | 217934147 |
| CVAMA3617XMA · cold climate | 58TN*B070C14**12 | 19.0 | 13.5 | 8.5 | 21,600 | 217934149 |
| CVAMA3617XMA · cold climate | 58TN*B070C17**16 | 19.0 | 13.5 | 8.5 | 21,600 | 217934150 |
| CVAMA3617XMA · cold climate | 58TN*B090C17**16 | 19.0 | 13.5 | 8.5 | 21,600 | 217934151 |
| CVAMA3617XMA · cold climate | 58TP*B045V14**12 | 19.0 | 13.5 | 8.5 | 21,400 | 217934152 |
| CVAMA3617XMA · cold climate | 58TP*B070V14**12 | 19.0 | 13.5 | 8.5 | 21,400 | 217934153 |
| CVAMA3617XMA · cold climate | 59CU5B060C17**16 | 19.0 | 13.5 | 8.5 | 21,400 | 217934156 |
| CVAMA3617XMA · cold climate | 58TP*B090V17**16 | 19.0 | 13.5 | 8.5 | 21,400 | 217934155 |
| CVAMA3617XMA · cold climate | 59MN7C060C17**14 | 19.0 | 13.0 | 8.5 | 21,800 | 217934157 |
| CVAMA3617XMA · cold climate | 59MN7C080C17**14 | 19.0 | 13.5 | 8.5 | 21,400 | 217934158 |
| CVAMA3617XMA · cold climate | 59SP6B080V17**16 | 19.0 | 13.5 | 8.5 | 21,600 | 217934163 |
| CVAMA3617XMA · cold climate | 59SU5B060M17**16 | 19.0 | 13.5 | 8.5 | 21,600 | 217934165 |
| CVAMA3617XMA · cold climate | 59TN6C060C17**14 | 19.0 | 13.5 | 8.5 | 21,600 | 217934167 |
| CVAMA3617XMA · cold climate | 59TN7A080C17**16 | 19.0 | 13.5 | 8.5 | 21,600 | 217934170 |
| CVAMA3617XMA · cold climate | 59TP6C080V17**16 | 19.0 | 13.5 | 8.5 | 21,600 | 217934175 |
| CVAMA3617XMA · cold climate | 59TP7A080V17**16 | 19.0 | 13.5 | 8.5 | 21,600 | 217934177 |
| CVAMA3617XMA · cold climate | OVMAAB042112 | 19.0 | 12.5 | 8.5 | 21,600 | 217934180 |
| CVAVA2517XMA · cold climate | 58CU*B040C17**12 | 19.0 | 13.5 | 8.5 | 21,400 | 217934242 |
| CVAVA2517XMA · cold climate | 58CU*B060C17**16 | 19.0 | 13.5 | 8.5 | 21,600 | 217934243 |
| CVAVA2517XMA · cold climate | 58SP*B045V14**12 | 19.0 | 13.5 | 8.5 | 21,400 | 217934244 |
| CVAVA2517XMA · cold climate | 58SP*B070V17**16 | 19.0 | 13.5 | 8.5 | 21,600 | 217934246 |
| CVAVA2517XMA · cold climate | 58SP*B070V14**12 | 19.0 | 13.5 | 8.5 | 21,400 | 217934245 |
| CVAVA2517XMA · cold climate | 58SP*B090V17**16 | 19.0 | 13.5 | 8.5 | 21,400 | 217934247 |
| CVAVA2517XMA · cold climate | 58SU*B040M17**12 | 19.0 | 13.0 | 8.5 | 21,600 | 217934248 |
| CVAVA2517XMA · cold climate | 58SU*B060M17**16 | 19.0 | 13.5 | 8.5 | 21,400 | 217934249 |
| CVAVA2517XMA · cold climate | 58TN*B070C14**12 | 19.0 | 13.5 | 8.5 | 21,600 | 217934251 |
| CVAVA2517XMA · cold climate | 58TN*B070C17**16 | 19.0 | 13.5 | 8.5 | 21,600 | 217934252 |
| CVAVA2517XMA · cold climate | 58TN*B090C17**16 | 19.0 | 13.5 | 8.5 | 21,600 | 217934253 |
| CVAVA2517XMA · cold climate | 58TP*B045V14**12 | 19.0 | 13.5 | 8.5 | 21,400 | 217934254 |
| CVAVA2517XMA · cold climate | 58TP*B070V14**12 | 19.0 | 13.5 | 8.5 | 21,400 | 217934255 |
| CVAVA2517XMA · cold climate | 58TP*B090V17**16 | 19.0 | 13.5 | 8.5 | 21,400 | 217934257 |
| CVAVA2517XMA · cold climate | 59MN7C060C17**14 | 19.0 | 13.0 | 8.5 | 21,800 | 217934259 |
| CVAVA2517XMA · cold climate | 59MN7C080C17**14 | 19.0 | 13.5 | 8.5 | 21,400 | 217934260 |
| CVAVA2517XMA · cold climate | 59SP6B080V17**16 | 19.0 | 13.5 | 8.5 | 21,600 | 217934265 |
Yearly running cost in 10 large cities
- Phoenix, AZ$720/yr
- Miami, FL$583/yr
- Houston, TX$645/yr
- Atlanta, GA$654/yr
- Los Angeles, CA$637/yr
- New York, NY$1,565/yr
- Chicago, IL$1,271/yr
- Denver, CO$1,057/yr
- Seattle, WA$650/yr
- Minneapolis, MN$1,308/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the Carrier 27VPA924A*030?
- The Carrier 27VPA924A*030 is rated at up to 19.5 SEER2 and 14.0 EER2 for cooling and up to 10.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 1222 certified matchups SEER2 ranges from 15.2-19.5.
- Is the Carrier 27VPA924A*030 good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 22,200 BTU/h at 5°F with a COP of 2.02, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
- How much does the Carrier 27VPA924A*030 cost to run per year?
- At its rated efficiency it costs about $583-$1,565 a year in electricity in large U.S. cities, depending on climate and local rates - for example $720 in Phoenix and $1,308 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the Carrier 27VPA924A*030?
- ENERGY STAR lists 1222 certified combinations for this outdoor unit. The highest-rated ones use FT5BD3617X, CAA**3721AM, FT5BD2417X.
- What refrigerant does the Carrier 27VPA924A*030 use?
- It uses R-454B.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 2 ton models
- Bryant 249VAN024**AA · cold climate19.5 SEER2 · 10.0 HSPF2
- Tempstar N5H9V24*K*AAA · cold climate19.5 SEER2 · 10.0 HSPF2
- Arcoaire Q5H9V24*K*AAA · cold climate19.5 SEER2 · 10.0 HSPF2
- Trane/American Standard 5HPL6024A1000A19.5 SEER2 · 9.4 HSPF2
- Trane/American Standard 5HCL9024A1000A · cold climate19.7 SEER2 · 8.8 HSPF2
- Navien, Inc. NAZ17V3622A119.5 SEER2 · 8.8 HSPF2
- Sure SP18AZ24AJVC · cold climate20.0 SEER2 · 8.5 HSPF2
- Trane 4TWV0X24A119.5 SEER2 · 8.7 HSPF2
See all 331 2 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of September 30, 2026. How we use the data.