HVAC Rated

2-ton central heat pump · Infinity 20 VS Heat Pump

Carrier 27VNA024A*030

Average cooling and heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #167 of 331 2 ton central heat pumps for cooling efficiency, and costs about $687 a year to run in a mixed climate like Atlanta.

SEER2
18.0 Cooling efficiency over a season
Average · beats 66%
HSPF2
9.0 Heating efficiency over a season
Average · beats 54%
EER2
10.5 Cooling efficiency on a 95°F day
Below average · beats 17%
Heat at 5°F
17,300 BTU/h70% of its 47°F output
Average · beats 47%

A good fit if…

  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 17,300 BTU/h at 5°F.
  • You want steady temperatures and quiet running - the compressor varies its speed.
  • You want a choice of indoor units - 104 certified pairings.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandCarrier
Also sold asBryant, Tempstar
Outdoor unit model27VNA024A*030
SeriesInfinity 20 VS Heat Pump
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceJune 12, 2023
Last certifiedMay 1, 2026
Cooling
SEER2Seasonal efficiency, higher is better18.0 (range 15.5-18.0)
EER2Efficiency at 95°F outdoors9.0-10.5
Cooling capacity22,400-24,200 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-9.0
Capacity at 47°F23,200-24,600 BTU/h
Capacity at 17°F19,600-20,800 BTU/h
Capacity at 5°F16,300-17,300 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.82-2.02
ENERGY STAR cold climateYes
Heating output as it gets colder70% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with CAA**3721AM*+UI at the standard test temperatures, in BTU/h:

Certified matchups104 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 104 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
CAA**3721AM*+UI · cold climate58CU*A040C17**1218.010.59.016,300215683687
CAA**2517AM*+UI · cold climate58CU*A040C17**1217.510.59.016,400215683597
CAA**2517AM*+UI · cold climate58TN*B070C17**1617.510.59.016,400215683603
CAA**3721AM*+UI · cold climate58TN*B070C21**2017.510.59.016,300215683695
CAA**3721AM*+UI · cold climate58TN*B090C17**1617.510.59.016,300215683697
CAA**3721AM*+UI · cold climate58CU*A060C17**1617.510.59.016,300215683689
CAA**3721AM*+UI · cold climate59TN6C100C21**2217.510.59.016,300215683717
CAA**3721AM*+UI · cold climate59MN7C080C17**1417.510.59.016,400215683709
CAA**3721AM*+UI · cold climate58TN*B110C21**2017.510.59.016,300215683701
CAA**3721AM*+UI · cold climate59TN6C080C17**1417.510.59.016,300215683715
CAA**2517AM*+UI · cold climate58TN*B070C14**1217.510.59.016,400215683601
CAA**3717AM*+UI · cold climate58TN*B070C14**1217.510.59.016,500215683671
CAA**2517AM*+UI · cold climate58TN*B090C17**1617.510.59.016,400215683605
CAA**2517AM*+UI · cold climate59TN6C080C17**1417.510.59.016,400215683615
CAA**3721AM*+UI · cold climate58CU*B060C17**1617.510.59.016,300215678393
CAA**3721AM*+UI · cold climate58TN*B090C21**2017.510.59.016,300215683699
CAA**3721AM*+UI · cold climate59TN7A100C21**2217.510.59.016,300215678423
CAA**3721AM*+UI · cold climate59MN7C100C21**2217.510.59.016,300215683711
CAA**3721AM*+UI · cold climate59TN6C060C17**1417.510.59.016,400215683713
CAA**3721AM*+UI · cold climate58TN*B070C17**1617.510.59.016,400215683693
CAA**3017AM*+UI · cold climate58TN*B070C17**1617.010.09.016,700215683629
CAA**3017AM*+UI · cold climate58TN*B090C17**1617.010.09.016,700215683631
CAA**2517AM*+UI · cold climate59TN7A060C17**1617.010.09.016,500215678243
CAA**3717AM*+UI · cold climate59TN6C060C17**1417.010.09.016,600215683683
CAA**3717AM*+UI · cold climate58CU*A060C17**1617.010.09.016,500215683667
CAA**2414AM*+UI · cold climate58TN*B070C14**1217.010.09.016,900215683573
CAA**3717AM*+UI · cold climate58TN*B070C17**1617.010.59.016,500215683673
CAA**3717AM*+UI · cold climate58TN*B090C17**1617.010.59.016,500215683675
CAA**3617AM*+UI · cold climate58TN*B090C17**1617.010.59.016,600215683653
CAA**2517AM*+UI · cold climate59TN6C060C17**1417.010.59.016,500215683613
CAA**3721AM*+UI · cold climate58TN*B045C17**1217.010.59.016,500215683691
CAA**3717AM*+UI · cold climate58CU*B060C17**1617.010.09.016,400215678353
CAA**2517AM*+UI · cold climate59MN7C080C17**1417.010.59.016,400215683609
CAA**3017AM*+UI · cold climate58CU*A040C17**1217.010.09.016,600215683621
CAA**2417AM*+UI · cold climate58TN*B070C14**1217.010.09.016,800215683583
CAA**3721AM*+UI · cold climate59CU5B100C21**2217.010.59.016,300215683703
CAA**3017AM*+UI · cold climate58TN*B070C14**1217.010.09.016,700215683627
CAA**2417AM*+UI · cold climate58TN*B090C17**1617.010.09.016,800215683587
CAA**2517AM*+UI · cold climate58CU*B040C17**1217.010.59.016,300215678223
CAA**2517AM*+UI · cold climate58CU*B060C17**1617.010.59.016,300215678233
CAA**2517AM*+UI · cold climate58TN*B045C17**1217.010.09.016,500215683599
CAA**3617AM*+UI · cold climate59TN6C080C17**1417.010.09.016,600215683663
CAA**3717AM*+UI · cold climate58CU*A040C17**1217.010.59.016,500215683665
CAA**3617AM*+UI · cold climate59TN6C060C17**1417.010.09.016,700215683661
CAA**3617AM*+UI · cold climate58CU*A040C17**1217.010.09.016,600215683643
CAA**3617AM*+UI · cold climate58CU*A060C17**1617.010.09.016,600215683645
CAA**3717AM*+UI · cold climate58TN*B045C17**1217.010.09.016,600215683669
CAA**2517AM*+UI · cold climate59TN7A080C17**1617.010.59.016,500215678253
CAA**2517AM*+UI · cold climate59MN7C060C17**1417.010.59.016,500215683607
CAA**3717AM*+UI · cold climate59TN6C080C17**1417.010.59.016,500215683685
CAA**3617AM*+UI · cold climate59TN7A080C17**1617.010.09.016,700215678333
CAA**3617AM*+UI · cold climate59MN7C060C17**1417.010.09.016,700215683655
CAA**3617AM*+UI · cold climate59MN7C080C17**1417.010.09.016,700215683657
CAA**3721AM*+UI · cold climate59TN7A060C17**1617.010.59.016,400215678403
CAA**3717AM*+UI · cold climate58CU*B040C17**1217.010.09.016,400215678343
CAA**3717AM*+UI · cold climate59TN7A080C17**1617.010.09.016,500215678373
CAA**3717AM*+UI · cold climate59MN7C080C17**1417.010.59.016,500215683679
CAA**3017AM*+UI · cold climate59TN6C080C17**1417.010.09.016,700215683641
CAA**3017AM*+UI · cold climate58CU*A060C17**1617.010.09.016,700215683623
CAA**3617AM*+UI · cold climate58TN*B070C14**1217.010.09.016,600215683649
Same unit, other model numbers2

These model numbers have exactly the same certified ratings and matchups as the Carrier 27VNA024A*030: the same equipment under another brand, or a variant code for voltage, colour or market. Everything on this page applies to them.

Yearly running cost in 10 large cities$606-$1,649

At each state's average electricity price and the city's typical heating and cooling hours.

Questions6
What is the SEER2 rating of the Carrier 27VNA024A*030?
The Carrier 27VNA024A*030 is rated at up to 18.0 SEER2 and 10.5 EER2 for cooling and up to 9.0 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 104 certified matchups SEER2 ranges from 15.5-18.0.
Is the Carrier 27VNA024A*030 good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 17,300 BTU/h at 5°F with a COP of 2.02, so it is still 2.0 times as efficient as electric resistance heat at that temperature.
How much does the Carrier 27VNA024A*030 cost to run per year?
At its rated efficiency it costs about $606-$1,649 a year in electricity in large U.S. cities, depending on climate and local rates - for example $751 in Phoenix and $1,381 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Is the Carrier 27VNA024A*030 the same as the Bryant 290VAN024**AA?
Yes, as far as the certified ratings go. ENERGY STAR lists 3 model numbers with identical efficiency, capacity and matchups, which means the same outdoor unit sold under a different brand or with a minor variant code (voltage, colour or region). The full list is on this page.
Which indoor units work with the Carrier 27VNA024A*030?
ENERGY STAR lists 104 certified combinations for this outdoor unit. The highest-rated ones use CAA**3721AM*+UI, CAA**2517AM*+UI, CAA**3717AM*+UI.
What refrigerant does the Carrier 27VNA024A*030 use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $747/yrYou save $455/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Carrier 27VNA024A*030
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$747
Current system, per year
$1,203
You save per year
$455
Payback
18.7 years
Net after 10 years
-$3,946

Cooling $454Heating $294Electricity used: 4,671 kWhSaved vs. a minimum-efficiency heat pump: $176

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of May 1, 2026. How we use the data.