HVAC Rated

2-ton central heat pump · Deluxe 23 VS Heat Pump

Arcoaire B5H3V24*K*AAA

Excellent cooling and heating efficiency for a 2-ton central heat pump, and certified for cold climates.

Ranks #1 of 331 2 ton central heat pumps for cooling efficiency, and costs about $628 a year to run in a mixed climate like Atlanta.

SEER2
23.0 Cooling efficiency over a season
Excellent · beats 99%
HSPF2
10.5 Heating efficiency over a season
Excellent · beats 96%
EER2
13.5 Cooling efficiency on a 95°F day
Excellent · beats 95%
Heat at 5°F
23,000 BTU/h81% of its 47°F output
Average · beats 58%

A good fit if…

  • You want low cooling bills - its SEER2 beats 99% of central heat pumps.
  • Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 23,000 BTU/h at 5°F.
  • It will heat most of the year - its HSPF2 beats 96% of central heat pumps.
  • You want steady temperatures and quiet running - the compressor varies its speed.

Think twice if…

  • Nothing stands out - its ratings have no weak spot for its class.

Calculate my running cost

Details

Specifications2 ton, R-454B
General
BrandArcoaire
Also sold asAirquest, Heil, Tempstar, Kenmore, Keeprite, Day & Night, Comfortmaker, ACIQ
Outdoor unit modelB5H3V24*K*AAA
SeriesDeluxe 23 VS Heat Pump
TypeCentral heat pump
Nominal size2 ton
CompressorVariable-speed units run longer at low powerContinuously variable
RefrigerantR-454B
Connected (smart) capableNo
On the market sinceAugust 8, 2025
Last certifiedJuly 16, 2026
Cooling
SEER2Seasonal efficiency, higher is better23.0 (range 18.0-23.0)
EER2Efficiency at 95°F outdoors10.5-14.0
Cooling capacity21,600-23,800 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.5-10.5
Capacity at 47°F24,800-28,200 BTU/h
Capacity at 17°F24,000-26,400 BTU/h
Capacity at 5°F19,100-23,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater1.84-2.10
ENERGY STAR cold climateYes
Heating output as it gets colder81% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EVM5X32M17A*+WALLCON at the standard test temperatures, in BTU/h:

Certified matchups3,771 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 3,771 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EVM5X32M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218407647
EVM5X32M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218407646
EVM5X32M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218407645
EVM5X32M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218407644
EVM5X32M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218407643
EVM5X32M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218407642
EVM5X32M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218407641
EVM5X32M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218407640
EVD5X38M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218408935
EVD5X38M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218408934
EVD5X38M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218408933
EVD5X38M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218408932
EVD5X38M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218408931
EVD5X38M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218408930
EVD5X38M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218408929
EVD5X38M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218408928
EVM5X44M21A*+WALLCON · cold climate*80CTL0901716B*23.013.59.522,400218408071
EVM5X44M21A*+WALLCON · cold climate*80CTL0901716B*23.013.59.522,400218408070
EVM5X44M21A*+WALLCON · cold climate*80CTL0901716B*23.013.59.522,400218408069
EVM5X44M21A*+WALLCON · cold climate*80CTL0901716B*23.013.59.522,400218408068
EVM5X44M21A*+WALLCON · cold climate*80CTL0901716B*23.013.59.522,400218408067
EVM5X44M21A*+WALLCON · cold climate*80CTL0901716B*23.013.59.522,400218408066
EVM5X44M21A*+WALLCON · cold climate*80CTL0901716B*23.013.59.522,400218408065
EVM5X44M21A*+WALLCON · cold climate*80CTL0901716B*23.013.59.522,400218408064
EVM5X44M21A*+WALLCON · cold climate*80CSU0401712B*23.014.09.522,400218408039
EVM5X44M21A*+WALLCON · cold climate*80CSU0401712B*23.014.09.522,400218408038
EVM5X44M21A*+WALLCON · cold climate*80CSU0401712B*23.014.09.522,400218408037
EVM5X44M21A*+WALLCON · cold climate*80CSU0401712B*23.014.09.522,400218408036
EVM5X44M21A*+WALLCON · cold climate*80CSU0401712B*23.014.09.522,400218408035
EVM5X44M21A*+WALLCON · cold climate*80CSU0401712B*23.014.09.522,400218408034
EVM5X44M21A*+WALLCON · cold climate*80CSU0401712B*23.014.09.522,400218408033
EVM5X44M21A*+WALLCON · cold climate*80CSU0401712B*23.014.09.522,400218408032
EVD5X38M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218629135
EVM5X44M21A*+WALLCON · cold climate*80CTL0901716B*23.013.59.522,400218629027
EVM5X44M21A*+WALLCON · cold climate*80CSU0401712B*23.014.09.522,400218629023
EVM5X32M17A*+WALLCON · cold climate*80CSU0601716B*23.013.59.522,400218628974
EVM5X32M17A*+WALLCON · cold climate*96CTN0801714B*22.513.59.522,400218407727
EVM5X32M17A*+WALLCON · cold climate*96CTN0801714B*22.513.59.522,400218407726
EVM5X32M17A*+WALLCON · cold climate*96CTN0801714B*22.513.59.522,400218407725
EVM5X32M17A*+WALLCON · cold climate*96CTN0801714B*22.513.59.522,400218407724
EVM5X32M17A*+WALLCON · cold climate*96CTN0801714B*22.513.59.522,400218407723
EVM5X32M17A*+WALLCON · cold climate*96CTN0801714B*22.513.59.522,400218407722
EVM5X32M17A*+WALLCON · cold climate*96CTN0801714B*22.513.59.522,400218407721
EVM5X32M17A*+WALLCON · cold climate*96CTN0801714B*22.513.59.522,400218407720
EVM5X32M17A*+WALLCON · cold climate*96CTN0601714B*22.513.09.522,600218407719
EVM5X32M17A*+WALLCON · cold climate*96CTN0601714B*22.513.09.522,600218407718
EVM5X32M17A*+WALLCON · cold climate*96CTN0601714B*22.513.09.522,600218407717
EVM5X32M17A*+WALLCON · cold climate*96CTN0601714B*22.513.09.522,600218407716
EVM5X32M17A*+WALLCON · cold climate*96CTN0601714B*22.513.09.522,600218407715
EVM5X32M17A*+WALLCON · cold climate*96CTN0601714B*22.513.09.522,600218407714
EVM5X32M17A*+WALLCON · cold climate*96CTN0601714B*22.513.09.522,600218407713
EVM5X32M17A*+WALLCON · cold climate*96CTN0601714B*22.513.09.522,600218407712
EVM5X32M17A*+WALLCON · cold climate*97CMN0801714B*22.513.09.522,400218407703
EVM5X32M17A*+WALLCON · cold climate*97CMN0801714B*22.513.09.522,400218407702
EVM5X32M17A*+WALLCON · cold climate*97CMN0801714B*22.513.09.522,400218407701
EVM5X32M17A*+WALLCON · cold climate*97CMN0801714B*22.513.09.522,400218407700
EVM5X32M17A*+WALLCON · cold climate*97CMN0801714B*22.513.09.522,400218407699
EVM5X32M17A*+WALLCON · cold climate*97CMN0801714B*22.513.09.522,400218407698
EVM5X32M17A*+WALLCON · cold climate*97CMN0801714B*22.513.09.522,400218407697
EVM5X32M17A*+WALLCON · cold climate*97CMN0801714B*22.513.09.522,400218407696
Yearly running cost in 10 large cities$475-$1,573

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the Arcoaire B5H3V24*K*AAA?
The Arcoaire B5H3V24*K*AAA is rated at up to 23.0 SEER2 and 13.5 EER2 for cooling and up to 10.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 3771 certified matchups SEER2 ranges from 18.0-23.0.
Is the Arcoaire B5H3V24*K*AAA good for cold climates?
Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 23,000 BTU/h at 5°F with a COP of 2.10, so it is still 2.1 times as efficient as electric resistance heat at that temperature.
How much does the Arcoaire B5H3V24*K*AAA cost to run per year?
At its rated efficiency it costs about $475-$1,573 a year in electricity in large U.S. cities, depending on climate and local rates - for example $627 in Phoenix and $1,347 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the Arcoaire B5H3V24*K*AAA?
ENERGY STAR lists 3771 certified combinations for this outdoor unit. The highest-rated ones use EVM5X32M17A*+WALLCON, EVD5X38M17A*+WALLCON, EVM5X44M21A*+WALLCON.
What refrigerant does the Arcoaire B5H3V24*K*AAA use?
It uses R-454B.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $644/yrYou save $614/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump Arcoaire B5H3V24*K*AAA
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$644
Current system, per year
$1,258
You save per year
$614
Payback
13.9 years
Net after 10 years
-$2,363

Cooling $352Heating $292Electricity used: 4,027 kWhSaved vs. a minimum-efficiency heat pump: $331

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 2 ton models

See all 331 2 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of July 16, 2026. How we use the data.