4-ton central heat pump · 4SHP17LE SERIES

AIREASE 4SHP17LE148P-**A

Below average cooling and heating efficiency for a 4-ton central heat pump, but not rated for cold climates.

Ranks #261 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,473 a year to run in a mixed climate like Atlanta.

SEER2
15.8 Cooling efficiency over a season
Below average · beats 18%
HSPF2
8.5 Heating efficiency over a season
Below average · beats 38%
EER2
13.0 Cooling efficiency on a 95°F day
Very good · beats 89%
Heat at 5°F
26,000 BTU/h54% of its 47°F output
Excellent · beats 94%

A good fit if…

  • You want a choice of indoor units - 452 certified pairings.

Think twice if…

  • You often see nights below 0°F - it is not cold-climate certified.
  • Cooling cost matters most - its SEER2 is below average for central heat pumps.
  • You mainly need heat - its HSPF2 is below average for central heat pumps.
  • You want the newest refrigerant - it uses R-410A, which is being phased down.

Calculate my running cost

Details

Specifications4 ton, R-410A
General
BrandAIREASE
Also sold asArmstrong Air
Outdoor unit model4SHP17LE148P-**A
Series4SHP17LE SERIES
TypeCentral heat pump
Nominal size4 ton
CompressorVariable-speed units run longer at low powerSingle stage
RefrigerantR-410A
Connected (smart) capableNo
On the market sinceOctober 1, 2022
Last certifiedOctober 27, 2025
Cooling
SEER2Seasonal efficiency, higher is better15.8 (range 15.2-15.8)
EER2Efficiency at 95°F outdoors12.5-13.0
Cooling capacity46,000-48,000 BTU/h
Heating
HSPF2Seasonal efficiency, higher is better8.0-8.5
Capacity at 47°F44,500-47,000 BTU/h
Capacity at 17°F30,000-31,800 BTU/h
Capacity at 5°F24,200-26,000 BTU/h
COP at 5°F2.0 = twice as efficient as a space heater2.16-2.38
ENERGY STAR cold climateNo
Heating output as it gets colder54% kept at 5°F

Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with EA(C;U)1P60C+TDR+TXV at the standard test temperatures, in BTU/h:

Certified matchups452 indoor units

The same outdoor unit scores differently with each indoor unit and furnace. The 60 highest-rated of 452 are shown. Ask your installer for the AHRI reference number of the exact system you are quoted.

Indoor unitFurnaceSEER2EER2HSPF2Heat @5°FAHRI ref.
EA(C;U)1P60C+TDR+TXVA80US2V080C20X15.813.08.325,200210329138
EAC4X60C+TDRA80US2V080C20X15.813.08.325,200211663260
EAC4X60C+TDRA80US2V080C20X15.813.08.325,200211662742
EA(C;U)1P60C+TDR+TXVA80US2V080C20X15.813.08.325,200210329748
7EC60CX-0*+TDRA80US2V080C20X15.813.08.325,200214714631
7EC60CX-0*+TDRA80US2V080C20X15.813.08.325,200214716124
EA(C;U)1P60C+TDR+TXVA80UH2E110C2015.613.08.325,200210329128
EAC4X60C+TDRA80UH2E110C1615.613.08.325,200211662729
EAC4X60C+TDRA80UH2E110C2015.613.08.325,200211663248
EAC4X60C+TDRA80UH2E110C1615.613.08.325,200211663247
EAC4X60C+TDRA80US2V100C20X15.613.08.325,400211663262
EA(C;U)1P60C+TDR+TXVA80UH2E110C2015.613.08.325,200210329738
EA(C;U)1P60C+TDR+TXVA80US2V100C20X15.613.08.325,400210329749
EAC4X60C+TDRA80US2V100C20X15.613.08.325,400211662744
EAC4X60C+TDRA80UH2E110C2015.613.08.325,200211662730
EA(C;U)1P60C+TDR+TXVA80US2V100C20X15.613.08.325,400210329139
EA(C;U)1P60C+TDR+TXVA80UH2E110C1615.613.08.325,200210329745
EA(C;U)1P60C+TDR+TXVA80UH2E110C1615.613.08.325,200210329135
EAH1P51C*+TDR+TXVA80US2V080C20X15.612.58.325,400211737301
EAH1P51C*+TDR+TXVA80US2V080C20X15.612.58.325,400211737302
EAH1P51C*+TDR+TXVA80UH1E090C2015.612.58.325,200211737257
EAH1P51C*+TDR+TXVA80UH1E090C2015.612.58.325,200211737258
7EC60CX-0*+TDRA80UH2E110C1615.613.08.325,200214714615
7EC60CX-0*+TDRA80UH2E110C2015.613.08.325,200214714616
7EH51CX-0*+TDRA80UH1E090C2015.612.58.325,200214714491
7EH51CX-0*+TDRA80US2V080C20X15.612.58.325,400214714497
7EC60CX-0*+TDRA80US2V100C20X15.613.08.325,400214714633
7EC60CX-0*+TDRA80UH2E110C1615.613.08.325,200214716108
7EC60CX-0*+TDRA80UH2E110C2015.613.08.325,200214716109
7EC60CX-0*+TDRA80US2V100C20X15.613.08.325,400214716126
7EH51CX-0*+TDRA80UH1E090C2015.612.58.325,200214715984
7EH51CX-0*+TDRA80US2V080C20X15.612.58.325,400214715990
EA(C;U)1P48B+TDR+TXVA80UH2E110C2015.612.58.124,200210329707
EA(C;U)1P60C+TDR+TXVA80UH1E090C2015.613.08.125,200210329736
EA(C;U)1P49C+TDR+TXVA80US2V080C20X15.613.08.125,400210329119
EA(C;U)1P49C+TDR+TXVA80UH1E090C2015.613.08.125,000210329719
EA(C;U)1P49C+TDR+TXVA80US2V080C20X15.613.08.125,400210329729
EAC4X48C+TDRA80UH2E110C2015.612.58.124,200211662698
EAC4X60C+TDRA80UH1E090C2015.613.08.125,200211663253
EA(C;U)1P49C+TDR+TXVA80UH1E090C2015.613.08.125,000210329109
EA(C;U)1P48B+TDR+TXVA80UH2E110C2015.612.58.124,200210329097
EAC4X49C+TDRA80UH1E090C2015.613.08.125,000211662714
EA(C;U)1P48C+TDR+TXVA80UH2E110C2015.612.58.124,200211663203
EA(C;U)1P60C+TDR+TXVA80UH1E090C2015.613.08.125,200210329126
EAC4X49C+TDRA80US2V080C20X15.613.08.125,400211662720
EA(C;U)1P48C+TDR+TXVA80UH2E110C2015.612.58.124,200211662685
EAC4X49C+TDRA80UH1E090C2015.613.08.125,000211663232
EAC4X49C+TDRA80US2V080C20X15.613.08.125,400211663238
EAC4X60C+TDRA80UH1E090C2015.613.08.125,200211662735
EAC4X48C+TDRA80UH2E110C2015.612.58.124,200211663216
7EC49CX-0*+TDRA80US2V080C20X15.613.08.125,400214714576
7EC60CX-0*+TDRA80UH1E090C2015.613.08.125,200214714624
7EC49CX-0*+TDRA80UH1E090C2015.613.08.125,000214714569
7EC48CX-0*+TDRA80UH2E110C2015.612.58.124,200214714533
7EC49CX-0*+TDRA80UH1E090C2015.613.08.125,000214716062
7EC48CX-0*+TDRA80UH2E110C2015.612.58.124,200214716026
7EC60CX-0*+TDRA80UH1E090C2015.613.08.125,200214716117
7EC49CX-0*+TDRA80US2V080C20X15.613.08.125,400214716069
BCE7E48M*4X-15.412.58.524,400210329094
BCE7E48M*4X-15.412.58.524,400210329704
Yearly running cost in 10 large cities$1,398-$3,435

At each state's average electricity price and the city's typical heating and cooling hours.

Questions5
What is the SEER2 rating of the AIREASE 4SHP17LE148P-**A?
The AIREASE 4SHP17LE148P-**A is rated at up to 15.8 SEER2 and 13.0 EER2 for cooling and up to 8.5 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 452 certified matchups SEER2 ranges from 15.2-15.8.
Is the AIREASE 4SHP17LE148P-**A good for cold climates?
It is not cold-climate certified: none of its matchups meet the ENERGY STAR cold-climate criteria (a COP of at least 1.75 at 5°F among other limits). In places with frequent sub-zero nights, pick a cold-climate 4-ton model.
How much does the AIREASE 4SHP17LE148P-**A cost to run per year?
At its rated efficiency it costs about $1,398-$3,435 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,702 in Phoenix and $2,831 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
Which indoor units work with the AIREASE 4SHP17LE148P-**A?
ENERGY STAR lists 452 certified combinations for this outdoor unit. The highest-rated ones use EA(C;U)1P60C+TDR+TXV, EAC4X60C+TDR, 7EC60CX-0*+TDR.
What refrigerant does the AIREASE 4SHP17LE148P-**A use?
It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.

Running cost and savings

Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.

Heat pump $1,662/yrYou save $764/yrSee details ↓
1. Where you live
Adjust heating and cooling hours

Filled in from your city's climate. Change them if you run the system much more or less than usual.

2. The heat pump AIREASE 4SHP17LE148P-**A
3. What it replaces
4. Price replace the example with your quote
Heat pump, per year
$1,662
Current system, per year
$2,426
You save per year
$764
Payback
23.6 years
Net after 10 years
-$10,364

Cooling $1,069Heating $593Electricity used: 10,389 kWhSaved vs. a minimum-efficiency heat pump: $191

Estimates use the unit's rated SEER2 and HSPF2, full-load hours derived from NOAA 1991-2020 degree days, average residential electricity prices from the U.S. EIA (12 months to July 2026) and fuel prices from EIA (2025 for natural gas, week of 2026-10-05 for propane and heating oil). Very cold days that need backup heat are not modelled. Federal minimum for comparison: 14.3 SEER2 / 7.5 HSPF2.

Similar 4 ton models

See all 319 4 ton central heat pumps, ranked

Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of October 27, 2025. How we use the data.