4-ton central heat pump · MVC SERIES
MDV MOE30U-48HFN1-M-[X1]
Below average cooling efficiency and very good heating efficiency for a 4-ton central heat pump, and certified for cold climates.
Ranks #260 of 319 4 ton central heat pumps for cooling efficiency, and costs about $1,442 a year to run in a mixed climate like Atlanta.
- SEER2
- 15.9 Cooling efficiency over a seasonBelow average · beats 18%
- HSPF2
- 9.6 Heating efficiency over a seasonVery good · beats 76%
- EER2
- 8.6 Cooling efficiency on a 95°F dayBelow average · beats 2%
- Heat at 5°F
- 46,500 BTU/h89% of its 47°F outputBelow average · beats 20%
A good fit if…
- Your winters get properly cold - it is ENERGY STAR cold-climate certified, with 46,500 BTU/h at 5°F.
- It will heat most of the year - its HSPF2 beats 76% of central heat pumps.
- You want steady temperatures and quiet running - the compressor varies its speed.
Think twice if…
- Cooling cost matters most - its SEER2 is below average for central heat pumps.
- You want the newest refrigerant - it uses R-410A, which is being phased down.
Details
Specifications
| General | |
|---|---|
| Brand | MDV |
| Also sold as | Alsetria, ECO-AIR |
| Outdoor unit model | MOE30U-48HFN1-M-[X1] |
| Series | MVC SERIES |
| Type | Central heat pump |
| Nominal size | 4 ton |
| CompressorVariable-speed units run longer at low power | Continuously variable |
| Refrigerant | R-410A |
| Connected (smart) capable | No |
| On the market since | October 12, 2022 |
| Last certified | June 9, 2026 |
| Cooling | |
| SEER2Seasonal efficiency, higher is better | 15.9 (range 15.6-15.9) |
| EER2Efficiency at 95°F outdoors | 8.2-8.6 |
| Cooling capacity | 47,000-48,000 BTU/h |
| Heating | |
| HSPF2Seasonal efficiency, higher is better | 9.4-9.6 |
| Capacity at 47°F | 50,000-52,000 BTU/h |
| Capacity at 17°F | 36,000-38,500 BTU/h |
| Capacity at 5°F | 46,000-46,500 BTU/h |
| COP at 5°F2.0 = twice as efficient as a space heater | 1.90 |
| ENERGY STAR cold climate | Yes |
Heating output as it gets colder
Every heat pump delivers less heat as the outdoor temperature drops. Certified output of its matchup with MVC-60HWFN1-M at the standard test temperatures, in BTU/h:
Certified matchups
The same outdoor unit scores differently with each indoor unit. Ask your installer for the AHRI reference number of the exact system you are quoted.
| Indoor unit | SEER2 | EER2 | HSPF2 | Heat @5°F | AHRI ref. |
|---|---|---|---|---|---|
| MVC-60HWFN1-M · cold climate | 15.9 | 8.6 | 9.6 | 46,500 | 217197644 |
| MVC-48HWFN1-M · cold climate | 15.6 | 8.2 | 9.4 | 46,000 | 207699011 |
| MVC-48HWFN1-M · cold climate | 15.6 | 8.2 | 9.4 | 46,000 | 208130395 |
| MVC-48HWFN1-M · cold climate | 15.6 | 8.2 | 9.4 | 46,000 | 208130406 |
Yearly running cost in 10 large cities
- Phoenix, AZ$1,660/yr
- Miami, FL$1,384/yr
- Houston, TX$1,486/yr
- Atlanta, GA$1,442/yr
- Los Angeles, CA$1,390/yr
- New York, NY$3,371/yr
- Chicago, IL$2,722/yr
- Denver, CO$2,252/yr
- Seattle, WA$1,374/yr
- Minneapolis, MN$2,782/yr
At each state's average electricity price and the city's typical heating and cooling hours.
Questions
- What is the SEER2 rating of the MDV MOE30U-48HFN1-M-[X1]?
- The MDV MOE30U-48HFN1-M-[X1] is rated at up to 15.9 SEER2 and 8.6 EER2 for cooling and up to 9.6 HSPF2 for heating. The exact figure depends on the indoor unit it is paired with; across its 4 certified matchups SEER2 ranges from 15.6-15.9.
- Is the MDV MOE30U-48HFN1-M-[X1] good for cold climates?
- Yes. At least one certified matchup meets the ENERGY STAR cold-climate criteria, delivering up to 46,500 BTU/h at 5°F with a COP of 1.90, so it is still 1.9 times as efficient as electric resistance heat at that temperature.
- How much does the MDV MOE30U-48HFN1-M-[X1] cost to run per year?
- At its rated efficiency it costs about $1,374-$3,371 a year in electricity in large U.S. cities, depending on climate and local rates - for example $1,660 in Phoenix and $2,782 in Minneapolis. The calculator on this page works it out for your city and compares it with your current system.
- Which indoor units work with the MDV MOE30U-48HFN1-M-[X1]?
- ENERGY STAR lists 4 certified combinations for this outdoor unit. The highest-rated ones use MVC-60HWFN1-M, MVC-48HWFN1-M.
- What refrigerant does the MDV MOE30U-48HFN1-M-[X1] use?
- It uses R-410A. R-410A is being phased down under the EPA AIM Act, and new systems are moving to R-454B and R-32.
Running cost and savings
Pre-filled with this model. Pick your city and what you heat with today; everything else is optional.
Similar 4 ton models
- Carrier 38MURAQ48AB3 · cold climate15.9 SEER2 · 9.6 HSPF2
- AIREASE 4SHP17LE148P-**A15.8 SEER2 · 8.5 HSPF2
- Arcoaire DLCURAH48ABK · cold climate15.9 SEER2 · 9.6 HSPF2
- Lennox ML17XP1-048-230A15.8 SEER2 · 8.5 HSPF2
- Johnson Controls HL19B602116.0 SEER2 · 7.8 HSPF2
- 1HVAC EZ-48-HP · cold climate15.6 SEER2 · 9.4 HSPF2
- Century HRG1860S1P16.0 SEER2 · 7.8 HSPF2
- Comfort-Aire A-VCD48SA-1 · cold climate15.6 SEER2 · 9.4 HSPF2
See all 319 4 ton central heat pumps, ranked
Source: ENERGY STAR Certified Heat Pumps (U.S. EPA), certification of June 9, 2026. How we use the data.